McCrometer Vera Mag 5000 Quick Start Installation Manual

McCrometer Vera Mag 5000 Quick Start Installation Manual

Electromagnetic flow meter
Hide thumbs Also See for Vera Mag 5000:

Advertisement

Quick Links

V
M
ERA
AG
®
WARNING!
!
Incorrect installation or removal of
meters can result in serious injury
WARNING
or death . Read the instructions in
this guide on the proper procedures
carefully.
Any person installing, inspecting, or maintaining
a McCrometer flowmeter should have a working
understanding of piping configurations and
systems under pressure.
Before adjusting or removing any meter,
be certain the system has depressurized
completely.
Be careful when lifting meters. Meters can cause
serious injury if lifted incorrectly or dropped.
Electromagnetic Flow Meter
Quick Start Installation Guide

About This Quick Start Guide

This Quick Start Guide is a supplement to the
Installation, Operation and Maintenance manual
supplied with this meter. It is intended to be
a quick reference for the basic installation and
reading of the Field Mag 5000.
It is designed to provide installation instructions
when the location of the sensor installation has
been predetermined.
Refer to the meter manual (30126-26 Vera Mag
5000 IOM manual) for information on these topis:
Preparation and planning for installation
Site location
Software configuration
Detailed information on external connections,
external power, outputs
About This Quick Start Guide . . . . . . . . . . . 1
1 .
2 .
Pipe Run Requirements . . . . . . . . . . . 2
3 .
4 .
Flow Meter Installation . . . . . . . . . . . 3
5 .
6 .
7 .
8 .
9 .
Installing Expansion Cards . . . . . . . . . 5
10 . Grounding . . . . . . . . . . . . . . . . . . . 6
Page 1
Vera Mag 5000
13SEP2024
30126-59 Rev. 1.0 | 13SEP2024
30126-59

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vera Mag 5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for McCrometer Vera Mag 5000

  • Page 1: Table Of Contents

    Flow Meter Installation . . . . . . . . . . . 3 Any person installing, inspecting, or maintaining Example Remote Mount Configuration 3 a McCrometer flowmeter should have a working Remote Mount Converter Installation . . 4 understanding of piping configurations and Installing Cables through Cable Glands systems under pressure.
  • Page 2: Check Shipping Crate Contents

    Sensor Orientation rough or improper handling should be reported The following installation recommendations to the transportation firm and McCrometer. If for should be followed (see figures below): any reason it is determined that the unit or parts of the unit should be returned to the factory,...
  • Page 3: Flow Meter Installation

    ® 4 . Flow Meter Installation The Field Mag requires grounding to ensure proper functioning and accuracy. See section 8 for grounding instructions and methods. Flanged Meter Installation Install the Vera Mag flow meter inline between two flanged end pipes. The flow meter may require grounding, depending on the environment they are being installed in.
  • Page 4: Remote Mount Converter Installation

    ® 6 . Remote Mount Converter Installation Mounting the ProComm 5000 Converter Note: This applies to the remote mount converter only. If possible, mount the converter in an electronics shed or environmental enclosure. The sun shield should be oriented in a direction to reduce sun damage and ensure readability.
  • Page 5: Procomm Converter Wiring Connection

    Figure 13. Terminal Block Diagram 9 . Installing Expansion Cards See the transmitter manual (30126-48 ProComm 5000 IOM manual) or the meter manual (30126-26 Page 7 30126-48 Rev. 1.0 | 23AUG2024 Vera Mag 5000 IOM manual). Page 5 30126-59 Rev. 1.0 | 13SEP2024...
  • Page 6: Grounding

    The two grounding rings and four gaskets require an additional installation width of 0.5”. When installing into a PVC or plastic pipe system, grounding rings are required for all sizes. NOTE: See the Vera Mag 5000 Series IOM Manual, Lit. #30126-26, for more information on grounding Speci cation Sheet using grounding rods and grounding rings.
  • Page 7 30126-44 Rev. 1.0 | 02JAN2024 Copyright © 2023 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer. Any published pricing, technical data, and instructions are subject to change without notice. Contact your McCrometer representative for current pricing, technical data, and instructions.

Table of Contents