Recommended Materials And Equipment; Tools And Software Requirements; Screws; Special Handling Of Components - HP xw6400 Service And Technical Reference Manual

Hp xw6400: reference guide
Hide thumbs Also See for xw6400:
Table of Contents

Advertisement

Keep work area free of nonconductive materials, such as ordinary plastic assembly aids and
Styrofoam.
Use field service tools, such as cutters, screwdrivers, and vacuums, that are conductive.

Recommended materials and equipment

Materials and equipment that are recommended for use in preventing static electricity include:
Antistatic tape
Antistatic smocks, aprons, or sleeve protectors
Conductive bins and other assembly or soldering aids
Conductive foam
Conductive tabletop workstations with ground cord of one-megohm ± 10% resistance
Static-dissipative table or floor mats with hard tie to ground
Field service kits
Static awareness labels
Wrist straps and footwear straps providing one-megohm ± 10% resistance
Material handling packages
Conductive plastic bags
Conductive plastic tubes
Conductive tote boxes
Opaque shielding bags
Transparent metallized shielding bags
Transparent shielding tubes

Tools and software requirements

Torx T-15 screwdriver or flathead screwdriver
Diagnostics software

Screws

The screws used in the workstation are not interchangeable. They might have standard or metric threads
and might be of different lengths. If an incorrect screw is used during the reassembly process, it can
damage the unit. HP strongly recommends that all screws removed during disassembly be kept with
the removed part, and then returned to their proper locations.

Special handling of components

The following components require special handling when servicing the workstation.
54
Chapter 4 Removal and replacement procedures
ENWW