# Set the IP address of VLAN-interface 2 to 192.168.4.22.
[Sysname] interface Vlan-interface 2
[Sysname-Vlan-interface2] ip address 192.168.4.22 255.255.255.0
[Sysname-Vlan-interface2] quit
# Enable the cluster function.
[Sysname] cluster enable
# Enter cluster view.
[Sysname] cluster
[Sysname-cluster]
# Configure a private IP address pool for the cluster. The IP address pool contains 30 IP addresses,
starting from 192.168.5.1.
[Sysname-cluster] ip-pool 192.168.5.1 255.255.255.224
# Name and build the cluster.
[Sysname-cluster] build aaa
[aaa_0.Sysname-cluster]
# Configure VLAN-interface 2 as the network management interface.
[aaa_0.Sysname] cluster
[aaa_0.Sysname-cluster] nm-interface Vlan-interface 2

Enhanced Cluster Feature Configuration Example

Network requirements
The cluster operates properly.
Add the device with the MAC address 0001-2034-a0e5 to the cluster blacklist, that is, prevent the
device from being managed and maintained by the cluster.
Save the current cluster topology as the base topology and save it in the flash of the local
management device in the cluster.
1-25