HP F2226A - 48GII Graphic Calculator User Manual page 677

Graphing calculator
Table of Contents

Advertisement

The lists in items 4 and 5 can be empty lists. Also, if no value is to be
selected for these options you can use the NOVAL command
(„°L@) @ @IN@@ @NOVAL@).
After function INFORM is activated you will get as a result either a zero, in
case the @CANCEL option is entered, or a list with the values entered in the fields
in the order specified and the number 1, i.e., in the RPN stack:
2:
1:
Thus, if the value in stack level 1 is zero, no input was performed, while it this
value is 1, the input values are available in stack level 2.
Example 1 - As an example, consider the following program, INFP1 (INput
Form Program 1) to calculate the discharge Q in an open channel through
Chezy's formula: Q = C⋅(R⋅S)
of the channel surface's roughness (typical values 80-150), R is the hydraulic
radius of the channel (a length), and S is the channel bed's slope (a
dimensionless numbers, typically 0.01 to 0.000001). The following program
defines an input form through function INFORM:
«
" CHEZY'S EQN" { { "C:" "Chezy's coefficient" 0} { "R:"
"Hydraulic radius" 0 } { "S:" "Channel bed slope" 0} } { }
{ 120 1 .0001} { 110 1.5 .00001 }
In the program we can identify the 5 components of the input as follows:
1. Title: " CHEZY'S EQN"
2. Field definitions: there are three of them, with labels "C:", "R:", "S:",
info strings "Chezy coefficient", "Hydraulic radius", "Channel bed
slope", and accepting only data type 0 (real numbers) for all of the
three fields:
{ { "C:" "Chezy's coefficient" 0} { "R:" "Hydraulic
radius" 0 } { "S:" "Channel bed slope" 0} }
3. Field format information: { } (an empty list, thus, default values used)
{v
v
... v
}
1
2
n
1
1/2
, where C is the Chezy coefficient, a function
INFORM »
Page 21-28

Advertisement

Table of Contents
loading

This manual is also suitable for:

48gii

Table of Contents