In A Wall Or Mantel; Horizontal Vent Installation - Pelpro FPP, IPP Owner's Manual

Dansons group inc wood pellet appliance owner's manual fpp bay view freestanding, ipp bay view insert / built-in, fpp freestanding, ipp insert / built-in
Hide thumbs Also See for FPP, IPP:
Table of Contents

Advertisement

B
UILT
CAUTION: DO NOT BLOCK VENT OPENING
The PELPRO Insert may be framed directly into a wall as either a horizontal or vertical vent installation see (figure
27, 28). The exhaust installation requirements are the same as for a freestanding stove. Refer to "Installing your
Freestanding Stove" for information concerning installation and proper hook-up of the exhaust.
NOTE: Built-In Installations require Enclosure
Dimensions that will be enclosed within the frame work are:
Shroud 1"
12 1/4"
10 3/4"
24"
Traditional Insert / Built-In
This example shows the
exhaust venting out and
up vertically
Requires Spacer Kit
#ACI-3HZ
The framed opening for this
Installation needs to be:
Tradition
Height
21"
Width
30"
Depth
17"
If constructing a chase, adequate
Insulation, vapor barrier, drywall,
And caulking must be used.
Can
adian Comfort Industries
Copyright 2004
-I
I
N
NSERT
24 3/4"
24"
6 1/2"
Exh au st
18 3/ 4"
+
3 ½"
+
8 1/4"
Ai r I nlet

Horizontal Vent Installation

Bay View
21 - 25"
30"
17"
FIGURE 27
Wood Surround
V04
www.pelprostoves.com
I
NSTALLATION
Kit #ACI-3HZ Horizontal Vent or #ACI-3VL Vertical Vent.
Shroud 1"
12 1/4"
10 3/4"
Ad justab le
Hopp er
7 3/4"
24"
Bay View Insert / Built-In
Exterior Wall
10'
Wood Frame
Construction
8"
2" Min.
Air gap
18"
Shroud
6"
4
Stand Offs
Part ACI-3HZ
20
26"
24"
19"
-
23"
+
+
3 ½"
+
8 1/4"
Air Inlet
2'
3" minimum
air gap
Wall Band /
Support Brkt
every 5'
6"
Clean Out Tee
PELPRO OWNERS MANUAL
Dansons Group Inc.
6 ½"
Exhaust
Exhaust
7 3/4"

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Pelpro FPP, IPP

This manual is also suitable for:

Ipp, fppFppIpp

Table of Contents