Burner And Nozzle Specifications - Whirlpool Akt 616/Nb Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

BURNER AND NOZZLE SPECIFICATIONS

Type of gas used
Type of burner
Rapid (R)
NATURAL GAS
Semi-rapid (SR)
(Methane)
G20
Auxiliary (AUX)
LIQUEFIED
Rapid (R)
PETROLEUM GAS
Semi-rapid (SR)
(Butane)
G30
Auxiliary (AUX)
LIQUEFIED
Rapid (R)
PETROLEUM GAS
Semi-rapid (SR)
G31
(Propane)
Auxiliary (AUX)
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 1,1 W
Injector marking
128 B
97 A
78 A
85 A
66 A
50
85 A
66 A
50
Model con guration
Rated thermal owrate
4 BURNERS
1R - 2SR - 1AUX
1R - 2SR - 1AUX
1R - 2SR - 1AUX
Rated thermal
Rated
ow rate
consumption
kW
3,00
286 l/h
1,65
157 l/h
1,00
95 l/h
3,00
218 g/h
1,65
120 g/h
1,00
73 g/h
3,00
214 g/h
1,65
118 g/h
1,00
71 g/h
Total rated consumption
(kW)
7,30
7,30
7,30
CATEGORY II2H3+
Reduced heat
Gas pressure
capacity
kW
min.
0,70
0,40
17
0,40
0,70
0,40
20
0,40
0,70
0,40
25
0,40
Air required (m
1m
695 l/h
531 g/h
521 g/h
mbar
rat.
max.
20
25
28-30
35
37
45
) for burning
3
of gas
3
9,52
30,94
23,80

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AKT 616/NB and is the answer not in the manual?

Table of Contents