Chapter 7
Configuring vPCs
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
see the Cisco Nexus 7000 Series NX-OS Unicast Routing Configuration Guide, Release 5.x.
Ensure that both the source and destination IP addresses use for the peer-keepalive message are unique
in your network.
The management port and management VRF are the defaults for these keepalive messages.
BEFORE YOU BEGIN
Ensure that you have enabled the vPC feature.
Ensure that you are in the correct VDC (or use the switchto vdc command).
SUMMARY STEPS
1.
2.
3.
4.
5.
6.
DETAILED STEPS
Command
Step 1
configure terminal
Example:
switch# configure terminal
switch(config)#
Step 2
vpc domain domain-id
Example:
switch(config)# vpc domain 5
switch(config-vpc-domain)#
OL-23435-03
configure terminal
vpc domain domain-id
peer-keepalive destination ip address [hold-timeout secs | interval msecs {timeout secs} |
{precedence {prec-value | network | internet | critical | flash-override | flash | immediate |
priority | routine}} | {tos {tos-value | max-reliability | max-throughput | min-delay |
min-monetary-cost | normal}} | tos-byte tos-byte-value} | source ipaddress | udp-port number |
vrf {name | management | vpc-keepalive}]
exit
(Optional) show vpc statistics
(Optional) copy running-config startup-config
Purpose
Enters global configuration mode.
Creates a vPC domain on the device, and enters the
vpc-domain configuration mode for configuration
purposes.