Cisco 2611 - Router - EN User Manual page 49

2600 series
Hide thumbs Also See for 2611 - Router - EN:
Table of Contents

Advertisement

Wiring the DC Power Supply
If you ordered a router with a DC power supply, follow the directions in this section to wire
the terminal block.
Warning
removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker
on the panel board that services the DC circuit, switch the circuit breaker to the OFF
position, and tape the switch handle of the circuit breaker in the OFF position.
Warning
sequence is ground to ground, positive to positive (line to L), and negative to negative
(neutral to N). Note that the ground wire should always be connected first and
disconnected last.
Warning
closed-loop or spade-type with upturned lugs. These terminations should be the
appropriate size for the wires and should clamp both the insulation and conductor.
Caution
contact screws. The recommended torque is 8.2 0.4 inch-lb.
Warning
switch handle and reinstate power by moving the handle of the circuit breaker to the ON
position.
Warning
field-wiring connections.
Before performing any of the following procedures, ensure that power is
The illustration shows the DC power supply terminal block. The proper wiring
When stranded wiring is required, use approved wiring terminations, such as
Do not overtorque the terminal block captive thumbscrew or terminal block
After wiring the DC power supply, remove the tape from the circuit breaker
Secure all power cabling when installing this unit to avoid disturbing
Wiring the DC Power Supply
Installing the Router 3-11