Download Print this page
Aspen AED-S Series Installation Manual

Aspen AED-S Series Installation Manual

Manufactured housing electric furnace

Advertisement

Quick Links

Certified technicians or those individuals
WARNING
meeting the requirements specified by NATE
may use this information.Property and
product damage or personal injury hazard
may occur without such background.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory, or mental capabilities,
or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children must be supervised to
ensure that they do not play with the appliance.
Product designed and manufactured to permit installation in
accordance with local and national building codes. It is the
installer's responsibility to ensure that the product is installed in
strict compliance with the aforementioned codes. Manufacturer
assumes no responsibility for damage (personal, product or
property) caused due to installations violating regulations.
Disconnect ALL power before servicing or
WARNING
installing this unit. Multiple power sources
may be present. Failure to do so may cause
property damage, personal injury, or death.
WARNING
Do not bypass safety devices.
Product designed and manufactured to
WARNING
permit installation in accordance with local
and national building codes. It is the
installer's responsibility to ensure that
product is installed in strict compliance with national and local
codes. Manufacturer takes no responsibility for damage (personal,
product or property) caused due to installations violating regu-
lations. In absence of local/state codes, refer to National Electric
Code: NFPA 90A & 90B Uniform Mechanical Code.
WARNING
This unit is NOT approved from outdoor
installations.
When this unit is installed in an enclosed
WARNING
area, such as a garage or utility room with
any Carbon Monoxide producing devices
(i.e. automobile, space heater, water heater
etc.) ensure that the enclosed area is properly ventilated.
AED/U(S/L) SERIES - MANUFACTURED
HOUSING ELECTRIC FURNACE
1. Safety Instruction
Potential safety hazards are alerted using the following symbols. The symbol is used in
conjunction with terms that indicate the intensity of the hazard. It is the responsibility of the
owner and the installer to read and comply with the safety information and the instructions
accompanying these symbols.
WARNING
This symbol indicates a potentially hazardous situation, which if not avoided,
could result in serious injury, property damage, product damage or death.
This symbol indicates a potentially hazardous situation, which if not avoided,
CAUTION
may result in moderate injury or property damage.
- 1 -
INSTALLATION GUIDE
Only factory authorized kits and accessories
should be used when installing or modifying
CAUTION
this unit unless it is so noted in these
instructions. Some localities may require a
licensed installer/service personnel.
The unit is designed for operation with
WARNING
208/240 V, single phase, 60 Hz power supply.
Aspen will not be responsible for damages
caused due to modification of the unit to operate with alternative
power sources.
If any hot work is to be conducted on the
WARNING
refrigerating equipment or any associated
parts, appropriate fire extinguishing
equipment shall be available to hand. Have a
dry powder or CO2 fire extinguisher adjacent to the charging area.
2. Introduction
This product is designed and manufactured to comply with
national codes. The product shall be installed in accordance
with national wiring regulations. It is the responsibility of the
installer to follow such codes and / or prevailing local codes /
regulations. The manufacturer assumes no responsibility for
equipment installed in violation of any codes or regulations.
The AED/U-(S/L) Series air handlers are versatile Downflow
or Upflow units. These air handlers have the following
standard features:
I. Application Versatility
One unit for all, Downflow (Front Return) or Upflow (Bottom
Return) as shipped (field-convertible for downflow-front & top
return and downflow-top return).
II. Cabinet
Sturdy, galvanized steel cabinet with painted doors. Cabinet
fully insulated with ½" faced insulation and anti-microbial, to
encapsulate glass fibers and to provide excellent R- value.
Stick pins ensure insulation remains in place. Units ship with
disposable filter in filter rails. Max coil assembly height of
27.5".
IO-A112 | AED/U IO-2024-09-REVB

Advertisement

loading
Need help?

Need help?

Do you have a question about the AED-S Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Aspen AED-S Series

  • Page 1 208/240 V, single phase, 60 Hz power supply. supervision or instruction concerning use of the appliance by a Aspen will not be responsible for damages person responsible for their safety. Children must be supervised to caused due to modification of the unit to operate with alternative ensure that they do not play with the appliance.
  • Page 2 III. Modular Heat Kits For closet installation, the return air opening can be on the front door, above the furnace casing on a wall, or on the elec- Heat kits are available with either breakers or terminal blocks. tric door’s louvered door (If applicable.) Available from 3 to 20 kW.
  • Page 3 BOTTOM PANEL (PART:151104) UPFLOW (BOTTOM RETURN) Fig. 4B-2A 4B-3. Filter Care COIL DECK ASM (PART: 141128) The filter should be checked every month. You may replace the filter by simply removing the single door and sliding out the existing one to replace it with a new filter. SOLID SINGLE DOOR (PART: 123202 TOP PANEL...
  • Page 4: Model Configuration

    4C. Conversion Kits MODEL CONFIGURATION RETURN DOOR KIT NEEDED FOR CONVERTIBLE TO (DEFAULT) (DEFAULT) (DEFAULT) (DEFAULT) CONVERSION DOWNFLOW / FRONT & TOP RETURN – LOUVER DOOR AEXK-01 AED-S-003 DOWNFLOW FRONT LOUVERED DOWNFLOW / TOP RETURN – SOLID DOOR AEXK-02 AED-L-003 UPFLOW / BOTTOM RETURN –...
  • Page 5 4D-2. KIT# AEXK-02 (DOWNFLOW/FRONT RETURN to DOWNFLOW/TOP RETURN) KIT#: AEXK-02 KIT#: AEXK-02 DOWNFLOW/FRONT RETURN TO DOWNFLOW/TOP RETURN CONVERSION DOWNFLOW/ FRONT RETURN TO DOWNFLOW/ TOP RETURN CONVERSION TOP SOLID PANEL (PART: 151110) (STEP#2) TOP PANEL (PART: 141125) (STEP#4) BLOCK OFF PLATE SCREWS X14 (PART: 151101) FILTER RAILS (L&R)
  • Page 6 4D-4. KIT# AEXK-03 (UPFLOW/BOTTOM RETURN to DOWNFLOW/FRONT RETURN) KIT#: AEXK-03 KIT: AEXK-03 UPFLOW/BOTTOM RETURN TO DOWNFLOW/FRONT RETURN CONVERSION UPFLOW/ BOTTOM RETURN TO DOWNFLOW/ FRONT RETURN CONVERSION TOP SOLID PANEL (PART: 151110) (STEP#7) SCREWS X15 BLOCK OFF PLATE (PART: 151101) (STEP#7) SOLID SINGLE DOOR (PART: 123202)
  • Page 7 4D-6. KIT# AEXK-01 (UPFLOW/BOTTOM RETURN to DOWNFLOW/TOP RETURN) KIT#: AEXK-01 KIT: AEXK-01 UPFLOW/BOTTOM RETURN TO DOWNFLOW/TOP RETURN CONVERSION UPFLOW/ BOTTOM RETURN TO DOWNFLOW/ TOP RETURN CONVERSION (L&R) FILTER RAILS (PARTS:151102) SCREWS X4 (STEP#5) SOLID SINGLE DOOR FILTER 18X20X1 (PART: 123202) (PART: 8767) (STEP#6) COIL DECK ASM...
  • Page 8 4D-8. KIT# AEXK-05 (DOWNFLOW/FRONT & TOP RETURN to DOWNFLOW/TOP RETURN) KIT#: P/N 123202 KIT#: AEXK-05 DOWNFLOW/ FRONT & TOP RETURN TO DOWNFLOW/ TOP RETURN CONVERSION DOWNFLOW/FRONT & TOP RETURN TO DOWNFLOW/TOP RETURN CONVERSION FILTER RAILS (TOP) (PART: 151102) BLOCK OFF PLATE (STEP#3) (PART: 151101) FILTER 18X20X1...
  • Page 9 4D-10. KIT# AEXK-03 (DOWNFLOW/TOP RETURN to DOWNFLOW/FRONT RETURN) KIT#: AEXK-03 KIT#: AEXK-03 DOWNFLOW/ TOP RETURN TO DOWNFLOW/ FRONT CONVERSION DOWNFLOW/TOP RETURN TO DOWNFLOW/FRONT CONVERSION TOP SOLID PANEL (PART: 151110) (STEP#3) BLOCK OFF PLATE (PART: 151101) TOP PANEL (STEP#1&2) SCREWS X8 (PART: 141125) (STEP#&2) FILTER RAILS (L&R)
  • Page 10: Electrical Installation

    4D-11. KIT# NONE (DOWNFLOW/TOP RETURN to UPFLOW/BOTTOM RETURN) KIT#: N/A KIT: N/A DOWNFLOW/TOP RETURN TO UPFLOW/BOTTOM RETURN CONVERSION DOWNFLOW/ TOP RETURN TO UPFLOW/ BOTTOM RETURN CONVERSION FILTER RAILS (L&R) (PART: 151102) (STEP#1&2) FILTER 18X20X1 (PART: 8767) (STEP#1) SOLID SINGLE DOOR (PART: 123202) (STEP#7) COIL DECK...
  • Page 11 6. Electrical Installation CONTINUED 6A. Single Stage Cooling with Electric Heat CONTINUED All models with 5, 6, 8 or 10kW electric heat are arranged for The Y wire from the thermostat is not connected at the elec- single circuit connections. Models larger than 10kW are ar- tric furnace.
  • Page 12 5. If outdoor unit instructions and charts are not available, require around 400 CFM of indoor air for every 1 ton of use Aspen’s provided charts. Make certain indoor air system cooling capacity. The air volume must be set prior to temperature is near comfort level setpoint 75F, prior to attempting system charge.
  • Page 13 12. Wiring Diagram for AED/U(S/L) Model - 13 -...
  • Page 14 373 Atascocita Rd. Humble, TX 77396 Phone: 281.441.6500 Toll Free: 800.423.9007 Fax: 281.441.6510 www.aspenmfg.com Subject to change without notice and without incurring obligation. © Copyright 2024 Aspen Manufacturing. All Rights Reserved. IO-A112 | AED/U IO-2024-09-REVB - 14 -...
Save PDF