Certified technicians or those individuals
!
WARNING
meeting the requirements specified by
NATE may use this information. Property
and product damage or personal injury hazard may occur
without such background.
All power sources should be disconnected
WARNING
!
prior to servicing. Failure to do so may
cause personal injury or property damage.
Product designed and manufactured to
!
WARNING
permit installation in accordance with lo-
cal and national building codes. It is the
installer's responsibility to ensure that product is installed
in strict compliance with national and local codes. Manufac-
turer takes no responsibility for damage (personal, product
or property) caused due to installations violating regula-
tions. In absence of local/state codes, refer to National Elec-
tric Code: NFPA 90A & 90B Uniform Mechanical Code.
When this unit is installed in an enclosed
WARNING
!
area, such as a garage or utility room with
any Carbon Monoxide producing devices
(i.e. automobile, space heater, water heater etc.) ensure that
the enclosed area is properly ventilated.
Only factory authorized kits and acces-
!
CAUTION
sories should be used when installing or
modifying this unit unless it is so noted in
these instructions. Some localities may require a licensed
installer/service personnel.
Unit is not approved for outdoor installa-
!
WARNING
tions.
The unit is designed for operation with
WARNING
!
208/240 V, single phase, 60 Hz power
supply. Aspen will not be responsible for
damages caused due to modification of the unit to operate
with alternative power sources.
AEL Series
Multi-Position Electric Furnace
1. Safety Instruction
Potential safety hazards are alerted using the following symbols. The symbol is used in conjunction with terms
that indicate the intensity of the hazard.
`
WARNING
!
This symbol indicates a potentially hazardous situation, which if not avoided,
could result in serious injury, property damage, product damage or death.
!
This symbol indicates a potentially hazardous situation, which if not avoided,
CAUTION
may result in moderate injury or property damage.
INSTALLATION GUIDE
2. Important Messages
2A. To the Installer:
"The United States Environmental Protection Agency ("EPA") has
issued various regulations regarding the introduction of disposal of
refrigerants in this unit. Failure to follow these regulations may harm
the environment and can lead to the imposition of substantial fines.
Because these regulations may vary due to the passage of new laws
we suggest that any work on this unit be done by a certified techni-
cian. Should you have any questions please contact the local office
of EPA." Some Aspen coils may include a Schrader valve on the
suction manifold. During installation, this Schrader valve must be
protected from heat or it may leak.
All Aspen coils are shipped with a nitrogen holding charge. DO NOT
install the coil if this charge is not present.
2B. To the Owner:
These instructions should be carefully read and kept near product,
for future reference. While these instructions are addressed primar-
ily to the installer, useful maintenance information is included. Have
your installing dealer acquaint you with the operating characteristics
of the product and periodic homeowner maintenance requirements.
As expressed in our product warranty, Aspen will not be billed for any
structural damage due to failure to follow these installation require-
ments. Once installed, Aspen coils may contain chlorofluorocarbons
(CFC's) or hydrochlorofluorocarbons (HCFC's). Under certain con-
ditions, CFC's & HCFC's may pose a health risk. Please notify a
licensed service technician immediately if you suspect your system
may contain a leak.
3. Codes And Regulations
This product is designed and manufactured to permit installation
in accordance with National Codes. It is the installer's responsibil-
ity to install the product in accordance with National Codes and/or
prevailing local codes and regulations. The manufacturer assumes
no responsibility for equipment installed in violation of any code or
regulation.
4. Inspection
This product has been inspected and run tested at the factory and
released to the transportation agency without known damage. In-
spect exterior of carton for evidence of rough handling in shipment.
Unpack carefully, if damage is found, report immediately to the trans-
portation agency.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aspen AEL Series

  • Page 1 When this unit is installed in an enclosed WARNING As expressed in our product warranty, Aspen will not be billed for any area, such as a garage or utility room with structural damage due to failure to follow these installation require- any Carbon Monoxide producing devices ments.
  • Page 2: Replacement Parts

    5. Replacement Parts Order all replacement parts through your local distributor. When ordering parts, give complete model and serial number as shown on the unit rating plate. 6. Specifications BLOWER DATA C F M V . E X T E R N A L S T A T I C * M O T O R M O T O R M O T O R...
  • Page 3: Electrical Installation

    STAGE1 STAGE2 STAGE1 STAGE2 National Environmental System Contractors Association Manual K, The AEL Series Electric Furnace is specifically designed for the use or whichever is applicable. AAL 15 XX 10.0 KW 5.0 KW in the upflow, horizontal and counterflow positions. Should the ap-...
  • Page 4: General Operation And Maintenance

    9. Start Up Do not store combustible materials or use WARNING gasoline or other flammable liquids or va- After all connections are made, start up and check out of the unit pors in the vicinity of this appliance. must be performed before proper evaluation of the entire system can be made.
  • Page 5 will pay big dividends in reduced operating cost and reduced service expense. Never operate comfort equipment without filter(s). 3) Fuses and/or Circuit Breakers- This comfort equipment should be connected to the building electric service in accordance with local and National Electric codes. This electrical connection will include over current protection in the form of circuit breakers.
  • Page 6 14. Wiring diagram for AEL models...
  • Page 7 Fax: 281.441.6510 www.aspenmfg.com Revised 06-2024. Subject to change without notice and without incurring obligation. Revised 06/08/20. Subject to change without notice and without incurring obligation. © Copyright 2020 Aspen Manufacturing. All Rights Reserved © Copyright 2024 Aspen Manufacturing. All Rights Reserved...

This manual is also suitable for:

AelsAelmAell

Table of Contents