Hide thumbs Also See for DM200 S-VDR:

Advertisement

Quick Links

Operators Manual
For DM200/DM300 S-VDR and DM400/DM500 VDR
Document Number 9200328
Version Number
Date
3.1
August 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DM200 S-VDR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danelec Marine DM200 S-VDR

  • Page 1 Operators Manual For DM200/DM300 S-VDR and DM400/DM500 VDR Document Number 9200328 Version Number Date August 2012...
  • Page 2: Revision Record

    Original issue of document March 2007 Minor errors corrected July 2008 Information related to DM200 S-VDR and DM400 VDR included in this manual. June 2011 Updated system overview and list of error codes to reflect changes to V3.1 of the S-VDR/VDR program code.
  • Page 3: Table Of Contents

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Contents REVISION RECORD ......................2 SCOPE AND PURPOSE ..................5 References........................5 Terms and Abbreviations ..................5 SYSTEM OVERVIEW ....................6 System overview for S-VDR..................6 2.1.1 Data Acquisition Unit..................6 2.1.2 Bridge Alarm Unit (BAU) ..................6 2.1.3...
  • Page 4 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 6.1.1 AC LED......................17 6.1.2 Link indications ....................17 6.1.3 AC breaker.......................17 6.1.4 LEDs in the Ethernet connector ...............18 6.1.5 Allocation of system labels for digital interfaces..........18 6.1.6 MR address......................18 OPERATION OF RVI....................19...
  • Page 5: Scope And Purpose

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 1 Scope and purpose Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR. 1.1 References 9200238 Installation Manual for DM200/DM300 S-VDR and DM400/DM500 VDR 9200327 Installation Manual for DM400/DM500 VDR Sensor Interface Unit...
  • Page 6: System Overview

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 2 System overview 2.1 System overview for S-VDR Firewire STP CAT5 S-DAU Capsule RS-422 Power 4 x Audio or Half slot in dpu 4 x Serial Gray print denotes that optional equipment is needed.
  • Page 7: System Overview For A Vdr

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 2.2 System overview for a VDR Firewire STP CAT5 Capsule RS-422 Power 4 x Audio or 4 x Serial or Half slot in dpu 8 x Analog or...
  • Page 8: Operation

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Operation 3.1 Bridge alarm Unit The BAU is the primary user interface for an installed operational VDR. It serves two purposes: • Alarm display • Interface for initiating backup an the VDR data disc 3.1.1 Alarm display...
  • Page 9 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S The system is capable of storing three incidents. The “Save” LED indicates when there is multiple, one or no save opportunity left (disk full). A backup will be protected for 30 days after which the space on the disc will be released automatically.
  • Page 10: Operation Dm200/Dm400 Dau

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 4 Operation DM200/DM400 DAU The door to the DAU must be locked after the VDR is installed and operating normally. This section of the manual is only relevant during installation and service or if the VDR data disc has to...
  • Page 11: Power Leds

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 4.1.1 Power LEDs BAT LED (blue) Steady light Battery fully charged Blinking Charging battery Off (short flash every 10 seconds) Battery is disconnected or has failed Error AC LED (blue)
  • Page 12: Vdr Status Display And Vdr Status Led

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 4.1.4 VDR status display and VDR status LED The status of the system is displayed using three digit codes on the VDR status display. The VDR status LED shows the severity of the codes. All information which is displayed on the VDR status display will also be displayed on the BAU after the system is booted and if the BAU is operational.
  • Page 13: Operation Dm300/Dm500 Dau

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 5 Operation DM300/DM500 DAU The door to the DAU must be locked after the VDR is installed and operating normally. This section of the manual is only relevant during installation and service or if the VDR data disc has to be removed following a serious incident.
  • Page 14: Leds On Psu

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 5.1 LEDS on PSU BAT LED (blue) Steady light Battery fully charged Blinking Charging battery Off (short flash every 10 seconds) Battery is disconnected or has failed Error...
  • Page 15: Ac Inlet

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 5.1.2 AC inlet The main power source for the VDR is ships AC (110V-240V). 5.1.3 DC inlet The VDR must be connected to the ships emergency power source (24VDC) if the emergency power system is based on DC.
  • Page 16: Leds In The Ethernet Connectors

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 5.2.3 LEDs in the Ethernet connectors Two LEDs are integrated into each Ethernet connect. The left LED (yellow) will be illuminated when a communication link is established. The right LED (green) will flicker depending on the traffic load.
  • Page 17: Operation Of Siu

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 6 Operation of SIU Module Rack Ethernet Link indications MR address AC LED AC Breaker AC inlet ports for slots Serial i/f Analog i/f Digital i/f module module...
  • Page 18: Leds In The Ethernet Connector

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 6.1.4 LEDs in the Ethernet connector Two LEDs are integrated into each Ethernet connect. The right LED (yellow) will be illuminated when a communication link is established to the DAU. The LED will flicker depending on the traffic load.
  • Page 19: Operation Of Rvi

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 7 Operation of RVI RVI address Ethernet port ST LED AC inlet Video i/f module 7.1.1 RVI address Must be set to “0”. 7.1.2 Ethernet ports ETH A must be connected to the DAU. Notice that the LEDs in the Ethernet connectors (RJ45) are inactive for this unit.
  • Page 20: Error Codes

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 8 Error codes Error codes and messages will be displayed by the BAU and VDR status display when errors are detected. An “R” after the error code denotes a repetitive alarm, see section 3.1.1.1. A “W” after the error code denotes a warning, see section 8.3...
  • Page 21 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S other error is discovered. STATUS The system receives no UTC from the GPS. Check that GPS is on. UTC timeout Check the signal from the GPS (use serial monitor in VDR explorer, WEB status or VGA status display).
  • Page 22 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S replaced. SERIAL module 1 The Serial Interface module in the DPU is using too much power. Power failure The module is probably faulty and must be replaced. VIDEO module 1 The Video Interface module in the DPU did not start.
  • Page 23 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S AUDIO module 2 The optional Audio Interface module 2 (half slot) did not start. If it Not started is not installed, audio channel 5 in the configuration must be disabled or else check the cable from the baseboard in the DPU to the module.
  • Page 24 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S interval CAPSULE The VDR is unable to record data to the capsule. Another error Not recording explaining why (e.g. #612 CAPSULE Can not find) is normally displayed in advance. Try to fix the preceding error else reboot system.
  • Page 25 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S See section 8.3 CAPSULE The VDR was unable read back data from the capsule too many Read back failed times within a given interval. CAPSULE The VDR found too many data errors within a given interval when Verification failed checking the data written to the capsule.
  • Page 26 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S WR error level 2 the first 24 hours of operation. More sophisticated measures than just retrying to write data were needed in order to fix the problem. The most likely cause is a temporarily disruption of communication from the VDR to VDR data disc or a defective VDR data disc.
  • Page 27 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S INTERNAL BACKUP A write-error (writing to the VDR data disc) has occurred during (Warning) the first 24 hours of operation. More sophisticated measures than WR error level 3 just retrying to write data did not fix the problem.
  • Page 28: Additional Error Codes For G2Vdr Installations

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 8.2 Additional Error codes for G2VDR installations SERIAL 400- A mandatory serial signal has disappeared. Check that the Timeout on SIxx source is on. Check the signal from the source (serial monitor in VDR explorer, WEB status or VGA status display).
  • Page 29: Description Of Warnings Issued During The First 24H Of Operation

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Missing (DI96-111) module. DIGITAL module 8 If all modules in a SIU are affected: Missing (DI112-127) Check the power to the SIU SERIAL module 3 Check the cable from the SIU to the DAU and link status, see Missing (SI16-23) section 5.2.3 and 6.1.4.
  • Page 30: Service And Maintenance

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 9 Service and maintenance The VDR requires an annual inspection carried out by a certified service organization. Please refer to “Installation Manual for DM200/DM300 S-VDR and DM400/DM500 VDR” for further details.
  • Page 31 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Click on “Properties”. 9200328-31A Page 31/42...
  • Page 32 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Select Internet Protocol (TCP/IP) and click on Properties. 9200328-31A Page 32/42...
  • Page 33 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Click on the radio button “Use the following IP address”. Type in an IP address within the range 10.0.0.101 to 10.0.0.254 Type in subnet mask equal to 255.0.0.0 Click on OK.
  • Page 34: Connect The Pc To The Vdr

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 9.3 Connect the PC to the VDR Connect the PC the VDR using a standard CAT5 path cable. Open an Internet browser on the PC Type in the IP address of the VDR in the browser address field. The IP address of the VDR is 10.0.0.100 (default).
  • Page 35 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Click “Run” to start the program. Click “Run” as this program is safe. The following program will start: 9200328-31A Page 35/42...
  • Page 36 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S If needed change the IP address, the default IP address is set to the default at program start. Pressing “Test” will verify that a connection can be made to VDR.
  • Page 37: Examination Of The Report

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 9.3.2 Examination of the report The following tests are made. The report starts with a summary. 9200328-31A Page 37/42...
  • Page 38 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 9.3.2.1 Verification of microphone functionality The self test in the microphones is activated and the result is printed in the report – either passed or failed 9.3.2.2 Verification of analog data...
  • Page 39 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 9.3.2.4 Verification of data on the audio tracks It is recommended that someone speaks on the bridge for the first 100 seconds after the verification program is started – i.e. during the microphone test and until download of data starts. If possible also use the VHF radio.
  • Page 40 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 9.3.2.6 Verification of video data It is recommended that the radar(s) are switched on before and after the verification tool is started. Passed: The image contains information. Error: The image contains little or no information.
  • Page 41: List Of Spare Parts

    Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S 9.4 List of spare parts Major Parts BMU (MIC) indoor 1000721 BMU (MIC) outdoor 1000722 Bridge Alarm Unit 1000720 Fixed Capsule, MK3 1300712 Installation kit DM300 2000736 Installation kit DM200...
  • Page 42 Operators Manual for DM200/DM300 S-VDR and DM400/DM500 VDR Copyright Danelec Marine A/S Empty compact flash (64M) 2000691 Capsule MK2 wo. cradle and beacon 2000693 Capsule MK3 wo. cradle and beacon 2300945 Straps for capsule release mechanism 4300013 Parts for the DM200 are also applicable for the DM400...

This manual is also suitable for:

Dm300 s-vdrDm400 vdrDm500 vdr

Table of Contents