Ecoflam BLU 1700.1 MD Manual
Ecoflam BLU 1700.1 MD Manual

Ecoflam BLU 1700.1 MD Manual

Gas burners
Hide thumbs Also See for BLU 1700.1 MD:

Advertisement

www.ecoflam-burners.com
GAS BURNERS
EN
BLU 1700.1 MD
Technical data
Operating instructions
Electric diagrams
Spare parts list
BLU 1700.1 PR TL 45MBAR 220-440-60
3143033

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLU 1700.1 MD and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecoflam BLU 1700.1 MD

  • Page 1 GAS BURNERS BLU 1700.1 MD Technical data Operating instructions Electric diagrams Spare parts list BLU 1700.1 PR TL 45MBAR 220-440-60 3143033...
  • Page 2 Overview - Index of contents Technical data Working fields Dimensions Operating instructions for authorised specialists 6 - 15 Electric diagrams 16 - 19 Spare parts list 20 - 21 Conformity declaration www.ecoflam-burners.com 420010518200...
  • Page 3 Overview Technical data BLU 1700.1 MD 1770 Burner output max/min kW - kcal/h 1.526.000 295.000 Operation Modulating with PID Regulating ratio Natural Gas (L.C.V. 8.570 kcal/Nm ), LPG (L.C.V. 22.260 kcal/Nm (G20) Hu = 10,35 kWh/m - (G25) Hu = 8,83 kWh/m...
  • Page 4 Calculation of burner output: QF = η QF = Burner output (kW) QN = Rated boiler output (kW) η = Boiler efficiency (%) www.ecoflam-burners.com 420010518200...
  • Page 5 - Dimensions D - D1 Model BLU 1700.1 PR d..° Model Ø a Ø b d°.. Ø a BLU 1700.1 PR 339,5 45° Ø b Packaging Model BLU 1700.1 PR 1290 GAS TRAIN DIMENSIONS: refer to GT manual 420010518200 www.ecoflam-burners.com...
  • Page 6 Ecoflam burners have been designed and built in compliance with all current regulations and directives. All burners comply to the safety and energy saving operation regulations within the standard of their respective performance range. The quality is guaranteed by a quality and management system certified in accordance with ISO 9001:2008.
  • Page 7: Burner Description

    BBCH: Burner Body with Combustion Head with flange. - 1 bag including : - multilanguage technical manual. - spanner. - screws, nuts and washer. GT: separate Gas Train KIT & ACS are managed and delivered separately 420010518200 www.ecoflam-burners.com...
  • Page 8: General Safety Functions

    Safety solenoid valve Thermally-triggered safety shut-off valve (installation resident) Gas pressure regulator Filter Gas ball valve (installation resident) 119pBr Measuring point for gas outlet pressure 119.1 Measuring point for gas pressure in valve space 119.2 Air pressure measuring point www.ecoflam-burners.com 420010518200...
  • Page 9: Control Panel

    105%. unit. Function - Control panel main switch I/0 SA on /off burner switch on-off lock-out lamp HLBT thermal lock-out lamp LAMTEC ETAMATIC S RWF 40 0: OFF 1: ON SA on/off HLBT 0: OFF 1: ON 420010518200 www.ecoflam-burners.com...
  • Page 10 • The cross-section of the gas line should be of a size designed to guarantee that the gas flow pressure does not drop below the specified level. • A manual shut-off valve (not supplied) must be fi tted upstream of the gas train. www.ecoflam-burners.com 420010518200...
  • Page 11 7.5 kW. Connect the gas train to the plugs on the For more information, please contact the 440V burner (fig.2). Ecoflam staff. The burners are produced with connections suitable for power supply 254V 440 V three-phase. The burners with electric motors of an...
  • Page 12 Risk of air blast! Continuously check CO, CO 2 and soot emissions when adjusting the output of the burner. Optimise combustion values in the event of CO formation. CO must not exceed 50 ppm. www.ecoflam-burners.com 420010518200...
  • Page 13 (i.e. for natural gas nom. pressure = 20 mbar, set knob to a value of 12 mbar; for LPG nom. pressure of G30/G31- 30/37 mbar, set knob to a value of 18 mbar). Screw up cover M. 420010518200 www.ecoflam-burners.com...
  • Page 14: Maintenance

    • Clean fan wheel and housing and check for damage. • Check and clean the mixing unit. • Check ignition electrodes block, readjust or replace as necessary. • Start burner, check flue gas data, correct burner settings if necessary. Ignition electrode www.ecoflam-burners.com 420010518200...
  • Page 15: Troubleshooting

    - Check the gas pressure with a pressure been satisfied, start the burner by pres- gauge. sing the reset button. - Check the detector value. - Check the burner cycle. If the burner fails to start: check the switch, the thermostats, the 420010518200 www.ecoflam-burners.com...
  • Page 16 Canale 3 servomotore gas Chanel n°3 for gas Sicurezze gas Gas safety Elettrovalvole gas Gas solenoid Fotocellula UV UV Flame sensor Trasformatore d'accensione Ignition transfomer Pressostato aria Air pressure switch Alimentazione di potenza motore ventilatore Elettrical power for fan motor www.ecoflam-burners.com 420010518200...
  • Page 17 Overview - Electric diagrams 420010518200 www.ecoflam-burners.com...
  • Page 18 Overview - Electric diagrams PINK YELLOW WHITE GREEN BLUE BLACK www.ecoflam-burners.com 420010518200...
  • Page 19 Overview - Electric diagrams 420010518200 www.ecoflam-burners.com...
  • Page 20 Overview - Spare parts list www.ecoflam-burners.com 420010518200...
  • Page 21 Overview - Spare parts list N° DESCRIPTION BLU 1700.1 MD code AIR PRESSURE SWITCH DUNGS LGW10 A2P 65323047 PRESSURE GAUGE 65321341 AIR INTAKE SET 65322346 COVER 65320676 GLASS 65320487 PEED WINDOM FRAME 65320488 MOTOR 4000 W 65325351 280 X 140 65321798...
  • Page 22 Déclaration de conformité pour for gas burners per bruciatori a gas brûleurs de gaz Noi, Nous , Ecoflam Bruciatori S.p.A. Ecoflam Bruciatori S.p.A. Ecoflam Bruciatori S.p.A. declare under our sole responsibility dichiariamo sotto la nostra déclarons sous notre responsabilite, that the gas burners named responsabilità, che i bruciatori a gas...
  • Page 23 420010518200 www.ecoflam-burners.com...
  • Page 24 Ecoflam Bruciatori S.p.A. reserves the right to make any adjustments, without prior notice, which is considered necessary or useful to its products, without affecting their main features Ecoflam Bruciatori S.p.A. si riserva il diritto di apportare ai prodotti le modifiche che riterrà necessarie o utili, senza pregiudicarne le caratteristiche principali.