Aiphone JV-1FD Installation Manual
Aiphone JV-1FD Installation Manual

Aiphone JV-1FD Installation Manual

Hands free color video intercom expansion monitor station
Hide thumbs Also See for JV-1FD:

Advertisement

Quick Links

Installation Manual
JV-1FD (Hands free color video intercom expansion monitor station)
To installers:
After installation is completed, be sure to hand the
accessories to the customer.
The illustrations and images used in this manual may
differ from the actual ones.
HTML manual
https://www.aip-info.net/file/manual/j/JV-1FD/JV-
1FD_INS/JV-1FD_INS_EN/content/
Issue date: Dec. 2023 FK2985 Ⓐ 1223 (H1.00) DL GZ 65293

Table of contents

Package contents ............................................. 2
Precautions ....................................................... 2
Part names and functions ............................... 3
Wiring ................................................................ 4
Precautions for wiring .......................................... 4
Wiring diagram and specifications ....................... 6
Precautions for installation ............................. 8
Mounting ........................................................... 8
After installation ............................................. 10
Check after installation....................................... 10
Installer settings ................................................. 11
Privacy notice ................................................. 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JV-1FD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aiphone JV-1FD

  • Page 1: Table Of Contents

    Issue date: Dec. 2023 FK2985 Ⓐ 1223 (H1.00) DL GZ 65293 Installation Manual JV-1FD (Hands free color video intercom expansion monitor station) Table of contents To installers: After installation is completed, be sure to hand the • accessories to the customer.
  • Page 2: Note

    Do not use with a power supply rated above the specified voltage. This may result in fire or electrical shock. Do not use the power supply other than Aiphone specified. This may result in fire or malfunction. Do not install two power supplies in parallel to a single input.
  • Page 3: General Precautions

    General Precautions Part names and functions  Install low-voltage lines at least 30 cm (12") away from high-voltage lines (AC 100V-240 V), especially inverter air conditioner wiring. This may result in interference or Expansion monitor station (JV- malfunction.  When installing or using the station, give consideration to 1FD) the privacy rights of subjects, as it is the responsibility of the system owner to post signs or warnings in accordance...
  • Page 4: Wiring

    Notification LED Wiring Refer to the "Operation Manual" for other indicators not listed. Precautions for wiring Description Blue light  Blue LED is lighting during Cable startup.  Blue LED is lighting when the  Use a parallel 2-conductor wiring cable for connection of a ringtone volume is set to "0".
  • Page 5 How to connect low voltage wires each other Crimping with a crimp sleeve Twist the stranded conductor around the solid conductor at least three times, then crimp them. Overlap more than half of the width and twist them at least twice. Soldering Twist the stranded conductor around the solid conductor at least three times.
  • Page 6: Wiring Diagram And Specifications

    Wiring diagram and specifications...
  • Page 7 (*1): Output specifications ATTENTION  Do not use the unused terminals for other purposes. Output method Dry contact (N/O)  The wiring between each device should not be in the Contact rating 24 VDC, 1 A (resistive load) same sheath wiring. (However, the wirings between the expansion monitor station and the master monitor station, and between the expansion monitor station and 24 V DC (*2): Output specifications...
  • Page 8: Precautions For Installation

    Precautions for installation Mounting  This unit is designed for indoor use only. Do not install at ATTENTION outdoor location.  Do not embed the station inside a wall.  Installing the device in the following locations could cause  To prevent malfunction, install the station at least 20 cm malfunction: (8") away from other devices (e.g., floor heating remote * Locations under direct sunlight...
  • Page 9 Strip 8 mm (5/16") of the wire jacket and insert it into the terminal. If it is difficult to insert, press and Installation video hold the release button [D] while inserting. https://www.aip-info.net/file/manual/j/JV-1FD/JV-1FD_INS/JV- 1FD_INS_EN/content/attachments/101967499/101968942.mp4 Remove the mounting bracket [A] from the back of the station.
  • Page 10: After Installation

    Surface wiring After installation The wires can be routed to the top or bottom of the station. If wiring is to be routed from the top of the station, cut the cable inlet [E]. Check after installation If there is a large amount of wiring [F], strip away the jacket of the wire up to the cable inlet.
  • Page 11: Installer Settings

    Setting procedure (e.g., setting the Installer settings door release duration) ATTENTION Tap one of the function buttons in standby mode.  Be sure to configure the settings according to the connected devices. Otherwise, the station may not The menu screen will be shown. operate properly.
  • Page 12: Privacy Notice

    Privacy notice https://www.aip-info.net/legal/privacy/ -12-...

Table of Contents