Page 4
Declaration of Conformity VIAVI recommends keeping a copy of the Declaration of Conformity that shipped with the unit with the test set at all times. Warranty Information Warranty information for this product is available on the VIAVI website at https://www.viavisolutions.com/en-us/warranty-information.
Page 5
VIAVI has established a take-back processes in compliance with the EU Waste Electrical and Electronic Equipment (WEEE) Directive, 2012/19/EU, and the EU Battery Directive, 2006/66/EC. Instructions for returning waste equipment and batteries to VIAVI can be found in the WEEE section of VIAVI’s Standards and Policies web page.
Page 6
For the VIAVI position statement on the use of Proposition 65 chemicals in VIAVI products, see the Hazardous Substance Control section of VIAVI’s Standards and Policies web...
Page 7
Record of Revisions Record of Revisions RECORD OF REVISIONS REV. DATE ACCEPTANCE June 2024 VIAVI Rev. 000 CX300 ComXpert NXDN Option Guide 22182561 ROR - i June 2024...
Page 9
CX300 ComXpert NXDN Option effectively and efficiently. Related Information This is the CX300 ComXpert NXDN Option Guide 22163052. This manual is to be used in conjunction with the following publications: • CX300 ComXpert Quick Start Guide, 22130635, which provides basic operating and safety information •...
Page 10
Refer to Newton’s Telecom Dictionary. and other publications appear in this typeface. Required arguments (text <p a s s w o r d > variables in code). 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 Preface - iii...
Page 11
Preface Contact Information Contact the Technical Assistance Center (TAC) for technical support or with any questions regarding this or another VIAVI products. • Phone: 1-844-GO-VIAVI • email: Techsupport.avcomm@viavisolutions.com For the latest TAC information, go to: https://www.viavisolutions.com/en-us/services-and-support/support/technical-assistance. Conventions Symbols and Markings...
Page 18
NXDN User Interface Layout ......... 1-6 NOTE Testing any transmitter function from a base station requires the use of a 40 dB 150 Watt high power attenuator. 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 1 - 1...
CX300 Overview CX300 Overview The CX300 ComXpert is a compact, bench-top communications test set for use in the Land Mobile Radio or Two-Way Communications Industry. The CX300 is ideal for performing preventative maintenance on two-way radios and their applicable support infrastructure.
When a NXDN software option(s) is purchased as a factory installed option, the NXDN software is ready to use when the test set is received from the factory. 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 1 - 3...
See the following steps for selecting and installing Options. Refer to the CX300 ComXpert Communication Service Monitor Operation Manual for more information on option selection. CX300 software is a field-upgradeable software which can be updated using StrataSync™...
Radio Test mode supports full duplex, Transmit, and Receive capabilities, providing simultaneous access to RF Generator and RF Receiver functions. Radio test mode is typically used for manual testing of subscriber or infrastructure equipment. 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 1 - 5...
The NXDN User Interface (UI) uses the same layout, methods of navigation, and control used in the CX300 Analog Duplex test and measurement mode of operation. Refer to the CX300 ComXpert Operation Manual for a detailed description about the UI layout, accessing system and test screens, and configuring controls and settings.
Normalize............2-13 NOTE Testing any transmitter function from a base station requires the use of a 40 dB 150 Watt high power attenuator. 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 2 - 1...
RF Generator controls and settings are configured from the RF Generator settings menu. Some controls are also accessed from the Quick Access Toolbar or Function Toolbar. Refer to the CX300 ComXpert Operation Manual for detailed descriptions of RF Generator controls and settings.
Analog modulation controls and settings are configured from the Analog Mod settings menu. Some controls are also accessed from the Quick Access Toolbar or Function Toolbar. Refer to the CX300 ComXpert Operation Manual for detailed descriptions of Analog Modulation controls and settings.
RF Receiver controls and settings are configured from the RF Receiver settings menu. Some controls are also accessed from the Quick Access Toolbar or Function Toolbar. Refer to CX300 ComXpert Communication Service Monitor Operation Manual for detailed descriptions of RF Receiver controls and settings.
When supported, the Avg Samples field is used to define the number of samples that are used to calculate average measurements. 2.2.2.2 Refresh Meters Meter readings are refreshed using the Refresh button ( 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 2 - 5...
• Bit Error Rate (BER) is a measure of the number of bit errors that occur in a given number of bit transmissions. This setting selects the NXDN test pattern of the receive Pattern signal. Rev 000 CX300 ComXpert NXDN Option Guide 22182561 2 - 6 June, 2024...
Analog demodulation controls and settings are configured from the Analog Demod settings menu. Some controls are also accessed from the Quick Access Toolbar or Function Toolbar. Refer to the CX300 ComXpert Communication Service Monitor Operation Manual for detailed descriptions of Analog Demod meters, controls, and settings.
9600 symbols per second. Symbol deviation measurements should be >945 and <1155 for rate of 4800 symbols per second and >2160 and <2640 for rate of 9600 symbols per second. Rev 000 CX300 ComXpert NXDN Option Guide 22182561 2 - 8 June, 2024...
Bit Error Rate Meter. NOTE BER is calculated over the entire data packet, not just the voice data. Use Standard NXDN Patterns for accurate BER measurements. 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 2 - 9...
1800 Hz. Conversely, a plot that is narrower than the dashed lines would indicate a symbol deviation less than 1800 Hz. 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 2 - 11...
Table 2-3 Eye Diagram Controls and Settings Control/Setting Description The Symbol Count button selects the number of Symbol Count Button symbols Rev 000 CX300 ComXpert NXDN Option Guide 22182561 2 - 12 June, 2024...
Normalize optimizes various performance parameters, including carrier leakage, IQ gain and balance, Third Order Intercept (IP3), and level correction. Refer to the CX300 ComXpert Operation Manual for additional information about this function. 22182561...
Page 37
Chapter 2 NXDN Test and Measurement Functions Normalize This page intentionally left blank. Rev 000 CX300 ComXpert NXDN Option Guide 22182561 2 - 14 June, 2024...
NXDN Measurements Chap ter 3 This chapter provides task-based instructions for using the CX300 ComXpert to establish NXDN calls and to perform key NXDN tests and measurements. This chapter describes how to use the CX300 in the following test scenarios.
OEM tuner or programming software for this test. 3.1.2 Equipment Needed The following equipment is required to perform the test procedures defined in this section: • CX300 ComXpert Test Set • RF Coaxial Cable and adapters 3.1.3 Hardware Setup Diagram...
Chapter 3 NXDN Measurements Testing NXDN Phase 1 Transceiver 3.1.4 Configuring the CX300 Test Set Select the CX300 ComXpert Tab. Select Communications Test on the Mode Pane. Select NXDN on the Measure Pane. Click the Done button. Select the RF Generator menu.
3.2.2 Equipment Needed The following equipment is required to perform the test procedures defined in this section: • CX300 ComXpert Test Set • RF Coaxial Cable and adapters • UUT OEM tuner or programming software (if required - see note below) NOTE BER may be measured in different manners depending on the radio manufacturer.
BER, until the UUT reports a BER of 5%. Record the RF Generator output level. If no further testing is to be conducted, disconnect and power Off the UUT. Rev 000 CX300 ComXpert NXDN Option Guide 22182561 3 - 6 June, 2024...
NXDN — Digital Mobile Radio (NXDN) Test System dBm — decibel milliwatts DES — Data Encryption Standard DEST ID — Destination Identifier DUT — Device Under Test 22182561 CX300 ComXpert NXDN Option Guide Rev 000 June, 2024 A - 1...
Page 45
U - Z TGID — Talk Group Identifier UI — User Interface USB — Universal Serial Bus UUT — Unit Under Test WACN — Wide Area Communications Network Rev 000 CX300 ComXpert NXDN Option Guide 22182561 A - 2 June, 2024...
Need help?
Do you have a question about the CX300 ComXpert and is the answer not in the manual?
Questions and answers