Download Print this page

Product Specifications - Honeywell COB02 Installation Manual

Charge-only base
Hide thumbs Also See for COB02:

Advertisement

Product Specifications

Parameter
Mechanical
Height
Length
Width
Weight
Electrical
Voltage
Current
Charge Time
Environmental
Charge Tem-
perature
Humidity
Mechanical
Drop
Vibration
ESD Immunity
IP Rating
Specification
2.6 in. (6.6cm)
9.8 in. (24.98mm)
4.05 in. (10.28cm)
10.05 oz. (285g)
4.5 to 5.5 volts
1A
5 hours
41° F to +104° F (5° C to +40° C)
Up to 95% non-condensing
Operational after 50 drops from 3.94 feet
(1.2m) to concrete within the temperature range
of -4° F (-20° C) to 122° F (50° C).
Complies with MIL-STD-810G, Method 514.6,
Annex C
Up to 20kV direct air
Up to 8 kV indirect coupling plane
IP51, immunity of foreign particles and dripping
water
7

Advertisement

loading
Need help?

Need help?

Do you have a question about the COB02 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Cob22