DMT 840MD User Manual

Myograph system
Hide thumbs Also See for 840MD:

Advertisement

Quick Links

MYOGRAPH SYSTEM -
840MD
USER GUIDE VOL. 3.0
Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 840MD and is the answer not in the manual?

Questions and answers

Summary of Contents for DMT 840MD

  • Page 1 MYOGRAPH SYSTEM - 840MD USER GUIDE VOL. 3.0 Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 2: Table Of Contents

    CHAPTER 4 - CLEANING AND MAINTENANCE CLEANING THE MYODYNAMICS MUSCLE STRIP MYOGRAPH MAINTENANCE OF THE FORCE TRANSDUCER MAINTENANCE OF THE LINEAR SLIDES APPENDIX 1 - READING A MILLIMETRE MICROMETER Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 3: Chapter 1 - Myodynamics Musle Strip Myograph Overview

    CHAPTER 1 - MYODYNAMICS MUSLE STRIP MYOGRAPH OVERVIEW Figure 1.1 MyoDynamics Muscle Strip Myograph with close-up of the chamber Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 4: Chapter 2 - Setting Up Myodynamics Muscle Strip Myograph

    Each chamber contains supports with mounting hooks to facilitate the mounting of muscle strips with sutures. DMT is also able to deliver a large variety of different mounting supports. Please contact DMT Sales to acquire more information about available mounting supports for the MyoDynamics Muscle Strip Myograph.
  • Page 5: Changing The Mounting Hooks (Figure 2.1)

    FROM USING A PERMANENT MARKER. STORE THE SUPPORTS IN THE PROVIDED PLASTIC CASE. NUMBERING THE SUPPORTS WILL SAVE TIME WHEN THE SUPPORTS ARE REPLACED. IT WILL REDUCE THE AMOUNT OF ADJUSTMENTS REQUIRED AFTER EACH CHANGE. Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 6: Adjustment Of The Mounting Hooks

    Gap 0.1 to 0.3 mm Figure 2.1 – Changing and adjusting the hooks Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 7: The First Force Calibration

    Prior to shipping the MyoDynamics Muscle Strip Myograph is subjected to two days of continuous testing, including a final force calibration. However, DMT recommends that a new force calibration is performed before using the MyoDynamics Muscle Strip Myograph for the first time. The force calibration procedure is described in detail in chapter 3.6.1 Force calibration in MyoDynamics Muscle Strip Myograph System -...
  • Page 8: Chapter 3 - Experimental Set-Up

    2. Position the sutures appropriately on both hooks so that they are ready for use when the muscle is mounted. Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 9 In User Gide “How to measure isometric force of striated muscle in vitro in an 820MS or 840MD Myograph”, we have examples with tips, tricks and how to do a proper ‘normalization’ of the mounted muscle before doing the real experiments.
  • Page 10: Chapter 4 - Cleaning And Maintenance

    If red or brown discolorations appear on the chamber sides or on the supports, the following cleaning procedure will work in most cases: Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 11 THE CHAMBER AND CLEANED INDIVIDUALLY TO ASSURE PROPER CLEANING OF ALL SUPPORT SURFACES. NEVER SOAK THE SUPPORTS IN ANYTHING STRONGER THAN 8% ACETIC ACID FOR EXTENDED PERIODS OF TIME (I.E. SEVERAL HOURS OR OVERNIGHT). Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 12: Maintenance Of The Force Transducer

    TRANSDUCER PINHOLE IS CHECKED AND SEALED AT LEAST ONCE A WEEK, ESPECIALLY IF THE MYOGRAPH IS USED FREQUENTLY. DMT TAKES NO RESPONSIBILITIES FOR THE USE OF ANY OTHER KINDS OF HIGH VACUUM GREASE OTHER THAN THE ONE SUPPLIED BY DMT.
  • Page 13 AND the transducer cannot be recalibrated, the force transducer is broken and needs to be replaced. If any other problems related to the force transducer are encountered, please contact DMT for advice or further instructions. Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 14 Figure 4.3 - Myograph without the bottom plate 4. Disconnect the connector to the transducer. 5. Remove the two transducer screws that hold the transducer housing, see figure 4.4. Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 15 11. Place some vacuum grease at the edge of the bottom plate. Place and tighten the bottom plates. IMPORTANT: CALIBRATE THE NEW FORCE TRANSDUCER BEFORE PERFORMING A NEW EXPERIMENT. Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 16: Maintenance Of The Linear Slides

    Check the linear slides (under the black covers) for grease at least once a week. In case of insufficient lubrication, grease the slides with the “Grease for Linear Slides” included with your system. Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 17: Appendix 1 - Reading A Millimetre Micrometer

    Reading on sleeve: 10000 µm No additional mark visible: 0 µm Thimble reading: 380 µm Figure A2.2 Example 1: Total reading: 10380 µm reading = 10380 µm Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 18 16000 µm Reading on sleeve: 500 µm One additional mark visible: 280 µm Thimble reading: 16780 µm Total reading: Figure A2.3 Example 2: reading = 16780 µm Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...
  • Page 19 Danish Myo Technology A/S | Tel.: +45 87411100 | Email: support@dmt.dk | Web: www.dmt.dk...

Table of Contents