10. SAFETY INFORMATION
1.SAFETY
PRECAUTIONS
The
following
check
should
be
performed
for the
continued
protection
of the customer
and service tech-
nician.
LEAKAGE
CURRENT
CHECK
Measure
leakage
current
to
a known
earth
ground
(water pipe, conduit, etc.) by connecting a leakage current
tester such as Simpson
Model 229-2 or equivalent between
the earth ground and all exposed metal parts of the appli-
ance
(input/output terminals, screwheads, metal overlays,
control shaft, etc.). Plug the AC line cord of the appliance
directly into
a 120V
AC
60Hz outlet and turn the AC
power switch on. Any current measured must not exceed
0.5mA.
Reading should
not be above
0.5mA
Leakage
current
tester
Device
under
Test ail
exposed metal
surfaces
2-wire cord
O
Also test with
plug reversed
(Using AC adapter
ground
plug as 'required)
AC
Leakage Test