D-Link DFE-2600 User Manual page 115

Dfe-2600 series ethernet/fast ethernet dual-speed managed/unmanaged stackable hubs
Hide thumbs Also See for DFE-2600:
Table of Contents

Advertisement

Delete
Click the Delete button to remove an entry.
Following are descriptions for the categories shown in the Alarm Table:
Owner
The entity that configured the entry and is therefore using the
resources assigned to it.
Index
An index uniquely identifying an entry in the alarm table. Each
such entry defines a diagnostic sample at a particular interval.
Interval
The interval in seconds over which the data is sampled and
compared with the rising and falling thresholds. When setting this vari-
able, care should be taken in the case of Delta sampling – the interval
should be set short enough that the sampled variable is very unlikely to
increase or decrease by more than 2^31
terval.
Variable The object identifier of the particular variable to be sampled.
Sample Type
culating the value to be compared against the thresholds. If the value of
this object is Absolute, the value of the selected variable will be com-
pared directly with the thresholds at the end of the sampling interval. If
the value of this object is Delta, the value of the selected variable at the
last sample will be subtracted from the current value, and the difference
compared with the thresholds.
Web-Based Network Management
The method of sampling the selected variable and cal-
1 during a single sampling in-
103

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents