Mounting the end stop to the swivel arm ............26 4.2.2 Requirements for mounting the device ............... 27 4.2.3 Requirements for ceiling mounting..............27 4.3 Assembly of the KaVoLUX 540 LED U ................27 4.3.1 ESTETICA E50 / E50 Life................... 27 4.3.2 ESTETICA E70 / ESTETICA E80................31 4.3.3...
Page 4
6.1.7 Turning the laser mode On and Off ..............86 6.1.8 Operation of the 3D joint .................. 88 6.2 Using the KaVoLUX 540 LED T operating light ..............88 6.2.1 Turning the operating light On and Off ............... 89 6.2.2 Setting the brightness ..................
See chapter on user instructions/hazard levels Original language German Service KaVo Technical service If you have any technical questions or complaints, please contact the KaVo Technical service: +49 (0) 7351 56-1000 service.einrichtungen@kavo.com or service.treatmentunits@kavo.com Please refer to the serial number of the product in all inquiries! For further in- formation, please visit: www.kavo.com...
1 User instructions | 1.1 Terms and conditions of warranty 1.1 Terms and conditions of warranty KaVo provides the final customer with a warranty that the product cited in the transfer form will function properly and guarantees zero defects in the material...
Terms and Conditions, Art. 28). Outside Germany NOTE KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery receipt.
Page 8
Instructions for use KaVoLUX 540 LED 1 User instructions | 1.2 Transport and storage Permissible stacking load Transport upright Properly dispose of cardboard 8 / 112...
- general regulations" are met in full. Regular servicing and safety checks are essential for the permanent assurance of the operating and functional safety of the KaVo product and for the preven- tion of damage and hazards. Testing and maintenance intervals: Maintenance must be performed once a year, the safety checks at intervals of 2 years.
Instructions for use KaVoLUX 540 LED 2 Safety | 2.1 Explosion hazard NOTE The paint may be damaged if the mounting pole slips into the lamp holder. Firmly hold the mounting pole when you insert it! Make sure not to crush any cables.
4 When you use the KaVo KEY Laser III or KEY Laser 3+, switch the operating light to laser mode. 4 Or switch off the operating light, do not use KaVo KEY Laser III or KEY Laser 3+ simultaneously with the operating light.
Instructions for use KaVoLUX 540 LED 2 Safety | 2.6 Risk of injury 4 Do not look directly into the lamp. 4 Avoid prolonged exposure of the eyes to the the light or wear safety goggles. Collisions and injuries could be caused by the large swivel range of the arms.
▪ ESTETICA E70 / E70 Vision ▪ ESTETICA E50 / E50 Life ▪ KaVo uniQa The KaVoLUX 540 LED T can be mounted in the following positions/to the fol- lowing treatment centres: ▪ on the ceiling ▪ Primus 1058 / 1058 Life ▪...
3.3 Operating light KaVoLUX 540 LED T NOTE The operating light KaVoLUX 540 LED T is exclusively designed for ceiling in- stallation and mounting to the KaVo treatment centres Primus 1058 / 1058 Life, Status 1080, Globus 1078, ESTETICA Sensus 1066, ESTETICA Comfort 1065, ESTETICA Standard 1063, ESTETICA E30 as well as for mounting to the DSEclinical dental simulation units.
Instructions for use KaVoLUX 540 LED 3 Product description | 3.4 Dimensions and swing range Components of the KaVoLUX 540 LED T ① Operating light head ② Handles ③ 3D joint ④ Control panel ⑤ Spring arm ⑥ Swivel arm ⑦...
Page 16
Instructions for use KaVoLUX 540 LED 3 Product description | 3.4 Dimensions and swing range Dimensions (in mm) Swing ranges (in mm) 16 / 112...
Supply voltage, frequency, power 3.6 Purpose – Proper use Product description The dental treatment lights from KaVo allow to illuminate the human oral cavity during general dental procedures. The operating lamp is specified as equipment for dentistry according to ISO 9680.
3 Product description | 3.7 Technical specifications and requirements Intended use KaVo treatment lights are used to illuminate a patient's oral cavity during dental treatment. The lights are mounted on a KaVo device system (dental treatment unit) or on the KaVo support system (Centro column).
Page 19
Instructions for use KaVoLUX 540 LED 3 Product description | 3.7 Technical specifications and requirements Fuse primary (ceiling adapter with T2.5A H SNT) F1 Fuse primary (ceiling adapter with T2.5A transformer) F1 Fuse secondary (ceiling adapter with T6.3A transformer) F3...
(office configura- tion) for KaVo units or third-party units (xx)* = technically possible, but KaVo recommends the KaVoLUX 540 LED U version 3.8 3.9 Accessories Mat.No. Material summary 1.009.4132 Mirror KaVoLUX 540 LED 20 / 112...
Page 21
Instructions for use KaVoLUX 540 LED 3 Product description | 3.9 Accessories Mat.No. Material summary 1.002.4489 Handle, sterilisable, gray 1.001.4472 Handle, white 1.008.8406 Ceiling mounting kit for KaVoLUX 540 NOTE To ensure the safety of the patient and prevent cross infection, the magnify- ing mirror must be used and adjusted by the office personnel.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.1 Packaging 4 Installation 4.1 Packaging 4.1.1 Transport and storage The packaging consists of styrofoam and is itself packaged in Superwell card- board. The instructions printed on the outside are for transportation and stor- age, and have the following meaning: 1.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.1 Packaging Gross weight: approx. 32 kg Net weight: approx. 18 kg 2. Stay bar Length: 930/1300 mm Width: 280 mm Height: 230 mm Gross weight: approx. 13 kg Net weight: approx. 10 kg 4.1.3 Removal from the packaging...
Page 24
Instructions for use KaVoLUX 540 LED 4 Installation | 4.1 Packaging 4 Grasp the operating light by the light bow ③ and by the spring arm ④ and remove from the packaging in a vertical upward direction together with the drape.
Page 25
Instructions for use KaVoLUX 540 LED 4 Installation | 4.1 Packaging 4 Slide the operating light into the mounting pole. 4 Do not remove the cable ties until the swivel arm has been mounted. 4 Do not remove the drape from the operating light until the swivel arm has been mounted.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.2 Requirements for mounting 4.2 Requirements for mounting 4.2.1 Mounting the end stop to the swivel arm Mounting the end stop to the swivel arm 4 Mount the silicone cover ①.
NOTE Comply with the regulations of IEC 601. Turn off the main switch before mounting. The assembly of the device KaVoLUX 540 LED comprises the following steps in the specified sequence: ▪ Installing the mounting pole ▪ Install the swivel arm ▪...
Page 28
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U 4 Removing the rear service flap. 4 Remove the front cover of the connection point. 4 Unscrew the cover ①. 4 Loosen screw ② below the main switch.
Page 29
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U 4 Ensure that the protective earth screw ⑥ and fastening screws ⑤ and ⑦ do not reach into the light holder. NOTE The paint may be damaged if the mounting pole slips into the lamp holder.
Page 30
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Installing the swivel arm 4 Install the washer ① (Mat. no. 1.009.0807) with the notch facing down- wards onto the attachment of the light mounting post (Mat. no.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Final tasks 4 Mount caps on the swinging and spring arm. 4 Run function test. 4 Perform the safety check according to the treatment centre.
Page 32
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Installing the mounting pole 32 / 112...
Page 33
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U 4 Remove device cladding (see assembly instructions of the treatment centre). 4 Slide the cover ring ① over the mounting pole. 4 Insert the mounting pole into the light holder up to the end stop ②.
Page 34
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U 4 Plug the control and supply cables ① into the line adapter ②. 4 Plug the control cable ④ (X87) into slot ⑤ (X87) on the central control PCB.
Page 35
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U ① CAN circuit device / ② CAN circuit patient chair Setting the CAN circuit device 4 Select the device type with the serial number from the following table and adjust the switch setting on the relevant printed circuit board.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U NOTE No adjustments need to be made to the CAN circuit patient chair The follow- ing table will provide full information. CAN circuit patient chair...
Page 37
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Installing the light mounting post NOTE The holder ② for the light mounting pole is not a height end limit stop for the light mounting pole.
Page 38
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U NOTE The light mounting pole must be adjusted appropriately together with the monitor or the panorama x-ray viewer to make sure that the handle does not shear off the tumbler filler.
4 Perform the safety check according to the treatment centre. 4 Mount the device covers. NOTE The KaVoLUX 540 LED U operating light is recognised automatically by the E70/E80 Vision treatment centre. No further settings need to be made on the treatment centre.
Page 40
ESTETICA E50/E50 Life NOTE The note bit OP light LED must be set to "0" in service mode U04 Index 9 to activate the KaVoLUX 540 LED U operating light on the treatment centre ES- TETICA E50/E50 Life. 40 / 112...
Page 41
NOTE The note bit OP light LED must be set to "1" in service mode U04 Index 28 to activate the KaVoLUX 540 LED U operating light on the treatment centre ES- TETICA E70/E80. 4 Press the "Remote Control" button until "U04" is shown on the display.
Page 42
ESTETICA E80 to SN 10100000 NOTE The note bit OP light LED must be set to "1" in service mode U04 Index 28 to activate the KaVoLUX 540 LED U operating light on the treatment centre ES- TETICA E70/E80. Also refer to:...
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U 4.3.5 KaVo uniQa WARNING Electrical power. Death or bodily injury from electric shock. 4 Before servicing, pull the mains plug out of the socket or completely discon-...
Page 44
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Removing the covers of the base of the unit ① Left side cover ② Right side cover ③ Service cover of the suction ④...
Page 45
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Installing the light mounting post 4 Slide the cover ring ① over the light mounting post ②. 4 Screw ⑥ can be used as a vertical limit stop (behind valve holder).
Page 46
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Installing the swivel arm 4 Install the washer ① (Mat. no. 1.009.0807) with the notch facing down- wards onto the attachment of the light mounting post (Mat. no.
Page 47
4 Connect the cable ① to the X12 on the unit processor board ②. NOTE The KaVoLUX 540 LED U operating light is recognised automatically by the treatment centre. No further settings need to be made on the treatment centre.
Page 48
Instructions for use KaVoLUX 540 LED 4 Installation | 4.3 Assembly of the KaVoLUX 540 LED U Final tasks: 4 Run function test. 4 Perform the safety check according to the treatment centre. 4 Mount the device covers. Mount the device covers The unit body is fitted with 7 covers.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Place the kickplate ⑧ on the chair base, but do not yet slide it forward. 4 Firstly, pre-mount special screws (C) in the hood of the connection area ⑦.
Page 50
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 If the fastening screws ⑥ project into the mount, lift the cover ⑤ and turn the screws back. 4 Pick up the insertion tool ① at the receiver tube and push it through the lamp mounting pole ③.
Page 51
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Thread the cover ② over the lamp mount pole. 4 Connect the supply line and protective earth conductor to the insertion tool ①...
Page 52
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Pull back the cables, ensuring that the connection terminals with shrinking hose remain in the support arm unit. 4 Pull back the excess lengths of the protective conductor and supply lines through the multimedia opening of the lamp mounting pole ①.
Page 53
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Mount the silicone cover ①. 4 Screw the brake and end stop into the lamp mount pole. Connecting the lines 4 Insert the cable 1 of the operating light into the cable holder and connect it at X24 (0V and 24V).
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4.4.2 Primus 1058 WARNING Electrical power. Death or bodily injury from electric shock. 4 Before servicing, pull the mains plug out of the socket or completely discon-...
Page 55
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Ensure that the protective earth screw ⑥ and fastening screws ⑤ and ⑦ do not reach into the light holder. NOTE The paint may be damaged if the mounting pole slips into the lamp holder.
Page 56
Connecting the lines 4 Run the protective conductor ⑧ and connect it to the body base. Manually operating the operating light by means of the KaVoLUX 540 LED T control panel: The operating light is directly connected to the terminal strip.
Page 57
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T Operating light automatic, On/Off function via the AP positions of the treatment centre: The operating light is connected via the DCA relay. NOTE ERGOcom light must not be connected to the DCA relay (X28) in this connec- tion option.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T KaVoLUX 540 LED T KaVoLUX 540 LED T Final tasks 4 Mount caps on the swinging and spring arm. 4 Run function test.
Page 59
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T Installing the mounting pole 4 Pivot the rear panel ① outward on the bottom and pull the lugs ② out in downward direction.
Page 60
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Unscrew the screws ① - ⑧. 4 Dismantle the side panels ①, ② 4 Loosen screws ③ on the disinfection container and remove the container ④.
Page 61
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Ensure that the protective earth screw ⑥ and fastening screws ⑤ and ⑦ do not reach into the light holder. NOTE The paint may be damaged if the mounting pole slips into the lamp holder.
Page 62
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T Installing the swivel arm 4 Install the washer ① (Mat. no. 1.009.0807) with the notch facing down- wards onto the attachment of the light mounting post (Mat. no.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T Final tasks 4 Mount caps on the swinging and spring arm. 4 Run function test. 4 Perform the safety check according to the treatment centre.
Page 64
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T NOTE In the operating centres ESTETICA Standard 1063 / Comfort 1065 / Sensus 1066, the lamp support Mat. no. 07404711 is not mounted as a standard and must be fitted subsequently.
Page 65
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Slide the cover ring ⑥ (Mat. no. 07105822) over the mounting pole ⑤. NOTE Paint can be damaged if the mounting pole slips into the light holder.
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T 4 Route the supply line (24 V AC) to the low voltage distributor circuit board and connect to the terminal strip X14 (polarity is not relevant).
Page 67
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T NOTE The paint may be damaged if the mounting pole slips into the lamp holder. Firmly hold the mounting pole when inserting. Screw in the depth stop screw ⑥...
Page 68
Instructions for use KaVoLUX 540 LED 4 Installation | 4.4 Assembly of the KaVoLUX 540 LED T ▪ Black wire is free Final tasks 4 Mount caps on the swinging and spring arm. 4 Run function test. 4 Perform the safety check according to the treatment centre.
- The installing technician is responsible for the professional performance of the installation. The ceiling mounting of the KaVoLUX 540 LED T comprises the following steps: ▪ Mount the ceiling adapter ▪ Install the swivel arm ▪ Install the stay bar ▪...
Page 70
Instructions for use KaVoLUX 540 LED 4 Installation | 4.5 KaVoLUX 540 LED T ceiling mounting 4 Screw the nuts tight so that the anchors grip the masonry. 4 Remove the nuts and washers. 4 Position the adapter base plate ⑤ in such a way that the arrow ⑥ is pointing 6 o´clock and secure with washers and nuts.
Page 71
Instructions for use KaVoLUX 540 LED 4 Installation | 4.5 KaVoLUX 540 LED T ceiling mounting 4 Position the swivel arm ④ on the holding rod in such a way that the cover points to the holding rod and the retaining pin ⑤ can be inserted into the designated borehole.
Page 72
Instructions for use KaVoLUX 540 LED 4 Installation | 4.5 KaVoLUX 540 LED T ceiling mounting 4 Route the supplementary protective conductor ⑧ and mains cable ⑨ through the borehole and through the stay bar until only the five-core end of the mains cable is protruding from the borehole.
Page 73
Instructions for use KaVoLUX 540 LED 4 Installation | 4.5 KaVoLUX 540 LED T ceiling mounting NOTE The conductor sheath may only extend 2 mm into the protective sleeve. 4 Draw the mains cable through cover ② (Mat. no. 1.004.5488).
Page 74
Instructions for use KaVoLUX 540 LED 4 Installation | 4.5 KaVoLUX 540 LED T ceiling mounting 4 With the stay bar ⑥ rotate the immediate plate ④ to the end of the slots so that the two arrows on the intermediate pate and ceiling adapter point in the same direction.
Page 75
Instructions for use KaVoLUX 540 LED 4 Installation | 4.5 KaVoLUX 540 LED T ceiling mounting 4 Insert the plug of the power cable ceiling adapter into the jack X2. 4 Connect the supply cable of the operating light to the terminal (U KaVoLUX 540), the polarity is irrelevant.
4.6 CentroInstallation of the KaVoLUX 540 LED To be able to mount the KaVoLUX 540 LED on the Centro stand, the routing of the lines in the swivel arm of the light needs to be changed. 4 Cut off the cable tie fixing the cables to the aluminium insert of the swivel arm.
Page 77
Instructions for use KaVoLUX 540 LED 4 Installation | 4.6 CentroInstallation of the KaVoLUX 540 LED 4 Remove the 4 Phillips head screws ① and pull the aluminium insert ② out of the swivel arm. 4 Route the lines ③ over the aluminium insert ② and pass them through the hole downwards.
Instructions for use KaVoLUX 540 LED 5 Mechanical settings | 5.1 Adjusting the swinging arm brake 5 Mechanical settings 5.1 Adjusting the swinging arm brake NOTE The swinging arm brake determines the ease with which the swinging arm ro- tates in the light mounting post.
Instructions for use KaVoLUX 540 LED 5 Mechanical settings | 5.3 Setting the light head brakes 5.3 Setting the light head brakes NOTE All movements of the light head can be set using different brakes. 5.3.1 Setting the rotary motion and 3D joint movement NOTE The cover ⑤...
Instructions for use KaVoLUX 540 LED 5 Mechanical settings | 5.3 Setting the light head brakes 5.3.2 Adjusting the light head brake NOTE The smooth running of the operating light head can be set using two brakes. - Brake ⑦ is for the presetting and needn´t be adjusted in normal cases. To set the brake ⑦, the cover ⑥...
Page 81
Instructions for use KaVoLUX 540 LED 5 Mechanical settings | 5.3 Setting the light head brakes Fine adjustment 4 Pivot the light head upwards until the orifice in the cover of the cross slot adjustment screw ① is visible. 4 Carry out the precision adjustment with the adjustment screw ①.
4 When you use the KaVo KEY Laser III or KEY Laser 3+, switch the operating light to laser mode. 4 Or switch off the operating light, do not use KaVo KEY Laser III or KEY Laser 3+ simultaneously with the KaVoLUX 540 LED operating light.
4 Switch the operating light to laser mode when you use the KaVo DIAGNO- dent. 4 Or switch off the operating light; do not use KaVo DIAGNOdent and the Ka- VoLUX 540 LED operating light simultaneously. CAUTION Premature curing of composite fittings.
Instructions for use KaVoLUX 540 LED 6 Operation | 6.1 Using the KaVoLUX 540 LED U operating light 6.1.1 Turning the operating light On and Off Sensor KaVoLUX 540 LED 4 Press the "Treatment light" button. 4 Hold your hand just in front of the sensor.
Instructions for use KaVoLUX 540 LED 6 Operation | 6.1 Using the KaVoLUX 540 LED U operating light 4 Press and hold down the switch of the foot control and press the "Dim oper- ating light" button until you hear the buzzer.
6.1.6 Setting the colour temperature NOTE The colour temperature of the KaVoLUX 540 LED U operating light can be set in five steps with the "X-ray viewer" button in the "Operating light on" operat- ing mode. The visual perception of the teeth can be adapted or enhanced by changing the colour temperature.
Page 87
Instructions for use KaVoLUX 540 LED 6 Operation | 6.1 Using the KaVoLUX 540 LED U operating light Sensor KaVoLUX 540 LED 4 Press the "Operating light“ button and the "Dim operating light" button sim- ultaneously on the dentist element of the treatment centre.
Instructions for use KaVoLUX 540 LED 6 Operation | 6.2 Using the KaVoLUX 540 LED T operating light 6.1.8 Operation of the 3D joint 4 Turn the switching ring to the left until it snaps into place. ð Operating light can be rotated 45° to the left or 45° to the right.
Instructions for use KaVoLUX 540 LED 6 Operation | 6.2 Using the KaVoLUX 540 LED T operating light 6.2.1 Turning the operating light On and Off NOTE The mains switch is switched on during ceiling mounting The treatment centre is switched on during mounting action on the unit (see...
Instructions for use KaVoLUX 540 LED 6 Operation | 6.2 Using the KaVoLUX 540 LED T operating light ð The COMPOsave mode can be recognised by the yellow light. 6.2.4 Switch on COMPOsave mode When operated in dimmed mode, the LED lamp functions like a dimmed halo- gen lamp.
Instructions for use KaVoLUX 540 LED 6 Operation | 6.2 Using the KaVoLUX 540 LED T operating light NOTE The time it takes for composites to harden is dependent on the brightness or the effective radiation intensity of the light: The working time is reduced with increasing brightness / effective radiation intensity.
Page 92
Instructions for use KaVoLUX 540 LED 6 Operation | 6.2 Using the KaVoLUX 540 LED T operating light Sensor KaVoLUX 540 LED 4 Press the „operating light“ button and the "operating light dimming" button simultaneously on the operating light. ð The laser mode switches on.
Instructions for use KaVoLUX 540 LED 6 Operation | 6.2 Using the KaVoLUX 540 LED T operating light 6.2.8 Operation of the 3D joint 4 Turn the switching ring to the left until it snaps into place. ð Operating light can be rotated 45° to the left or 45° to the right.
7 Reprocessing methods DIN EN ISO 17664 NOTE The reprocessing methods are specified in the Care instructions. Please note also the corresponding hygiene video on the KaVo website. Please use the QR code or the following link: https://www.kavo.com/hygiene-easy-way 7.1 General care instructions CAUTION Blinding and dazzling due to damaged glass cover of treatment light.
Instructions for use KaVoLUX 540 LED 7 Reprocessing methods DIN EN ISO 17664 | 7.2 Cleaning and disinfection of light, glass cover and mirror 7.2 Cleaning and disinfection of light, glass cover and mirror NOTE Only clean the light and cover after the light has been switched off and cooled down.
Instructions for use KaVoLUX 540 LED 7 Reprocessing methods DIN EN ISO 17664 | 7.4 Sterilisation 7.4 Sterilisation 7.4.1 Sterilising the handles NOTE The white handles (Mat. no. 1.001.4472) cannot be sterilised. 4 Sterilise the grey handles (Mat. no. 1.002.4489) for 4 minutes at 134 °C ±...
8.1 Mounting the device NOTE The test instructions for the KaVoLUX 540 LED U / T to be mounted to devices are described in the instructions for use of the respective treatment centre. The measurement of the protective earth, defined in the instructions for use for the relevant treatment centre, must be extended to include the measuring points "Scan the light head of the operating light KaVoLUX 540 LED with the...
Page 98
NOTE KaVo offers a medical device book for keeping an inventory and recording es- sential master data on the medical device. The medical device book is only available in German (mat. no. 0.789.0480).
Page 99
Instructions for use KaVoLUX 540 LED 8 Safety check – Test instructions | 8.2 Ceiling mounting NOTE If it is impossible to check single ME devices that are functionally connected to an ME system individually for technical reasons, the ME system must be checked as a whole.
Instructions for use KaVoLUX 540 LED 8 Safety check – Test instructions | 8.2 Ceiling mounting 8.2.2 Instructions for the safety check Visual inspection (inspection by examination) ▪ Check the following items in advance: Has the configuration of the ME device or the ME system been changed since the last inspection? ▪...
Page 101
L & N on the power input board need not be disconnected. The adapter cable ② is included in the delivery of the KaVo measuring cable and is required for older treatment centres that are not equipped with an X2 connector.
Page 102
4 Remove the connector X2 from the mains plate and plug into the matching connector X2 of the KaVo measuring line (Mat. no. 0.411.8811). 4 Plug the second connector X2 of the KaVo measuring line into the mains plate (X2).
Page 103
Additional measuring points ACP X must be taken into consideration in the presence of accessories. ACPs on the operating light KaVoLUX 540 LED No ACPs need to be connected to the operating light during the measurement with the protective earth conductor (PE), as all relevant parts are connected to the protective earth conductor (PE)before they leave the factory and are thus included in the test.
Page 104
Instructions for use KaVoLUX 540 LED 8 Safety check – Test instructions | 8.2 Ceiling mounting Scan the ceiling adapter of the treatment light with the probe ① Base plate for the ceiling adapter ② Surroundings of the protective conductor connector ③...
Page 105
Instructions for use KaVoLUX 540 LED 8 Safety check – Test instructions | 8.2 Ceiling mounting Scan the light head of the operating light KaVoLUX 540 LED with the probe ① Fastening screw of the handle support when the gripping sleeve...
Page 106
Instructions for use KaVoLUX 540 LED 8 Safety check – Test instructions | 8.2 Ceiling mounting ▪ The basic functions of the operating light must be guaranteed. ▪ The treatment light must be fit for use. ▪ There must be no irregularities, noise or abrasion, etc., present.
Instructions for use KaVoLUX 540 LED 8 Safety check – Test instructions | 8.2 Ceiling mounting 8.2.3 Test protocol for the safety check Test Protocol - Safety Check (Test of safety and function according to §7 section 3 Medical Device Operation Ordinance)
Instructions for use KaVoLUX 540 LED 9 Troubleshooting 9 Troubleshooting NOTE If disturbance arises, a technician authorised by KaVo must be engaged for the remedial action. Malfunction Cause Remedy Treatment light with Defective. 4 Have the device functional disturbance / checked by an au- without function.
Instructions for use KaVoLUX 540 LED 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 10.1 Operating envir- onment and EMC warning notes 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 10.1 Operating environment and EMC warning notes This product is neither life-sustaining nor coupled to the patient.
Page 110
Instructions for use KaVoLUX 540 LED 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 10.2 Results of the electromagnetic tests Requirement Class / test level [30 MHz – 1000 MHz] DIN EN 61000-3-2 VDE 0838-2 / 03.2010...
Page 111
Instructions for use KaVoLUX 540 LED 10 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 10.2 Results of the electromagnetic tests Requirement Class / test level 6 V in amateur radio bands DIN EN 61000-4-8 VDE 0847-4-8 / 11.2010...
Need help?
Do you have a question about the KaVoLUX 540 LED and is the answer not in the manual?
Questions and answers