RADWAG TMX User Manual
RADWAG TMX User Manual

RADWAG TMX User Manual

1-load-cell multifunctional scales, 4-load-cell platform scales, pallet and beam scales, track scales

Advertisement

Quick Links

TMX
1-LOAD-CELL MULTIFUNCTIONAL SCALES
4-LOAD-CELL PLATFORM SCALES
PALLET AND BEAM SCALES
TRACK SCALES
USER MANUAL
ITKU-36-10-03-24-EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TMX and is the answer not in the manual?

Questions and answers

Summary of Contents for RADWAG TMX

  • Page 1 1-LOAD-CELL MULTIFUNCTIONAL SCALES 4-LOAD-CELL PLATFORM SCALES PALLET AND BEAM SCALES TRACK SCALES USER MANUAL ITKU-36-10-03-24-EN...
  • Page 2 MARCH 2024...
  • Page 3 PRECAUTIONS Prior to installation, use or maintenance activities, carefully read this user manual. Use the TMX scale only as intended. Prior to the first use, carefully read this user manual. Use the device only as intended. Place weighed loads in the centre of the weighing pan.
  • Page 4: Table Of Contents

    7. INSTALLATION ..............................14 7.1. Unpacking and Installation ........................14 7.1.1. 1-Load-Cell Multifunctional Scales ....................14 7.1.2. Platform Scales: TMX.4.xx.C, TMX.4.xx.H, TMX.4.xx.H/Z Series ..........14 7.1.3. Ramp Scales: TMX.4N Series....................... 14 7.1.4. Track Scales: TMX.2K Series ......................15 7.2. Levelling: 1-Load-Cell Platform Scales ..................... 16 7.3.
  • Page 5: Intended Use

    The TMX scale is an original device consisting of two units: the computer and the weighing module, placed in one housing. Both of these units are connected via an internal interface.
  • Page 6: Maintenance

    3. MAINTENANCE In order to ensure safety in the course of cleaning, it is necessary to disconnect the device from the mains. With this condition met, uninstall the weighing pan and other detachable components. Cleaning of the weighing pan while still installed may cause damage of the measuring system.
  • Page 7 These are much more resistant to long-lasting harsh conditions typical for slaughterhouses and livestock purchase sites. Powder-coated livestock scales can be used for rare small volume production, they must be stored clean in dry storage area and can be washed using water with detergent. Do not use any agents or cleansers that are not intended to come into contact with skin (i.e.
  • Page 8: Service And Repair

    In case of any sign of damage, it is necessary to disconnect the device form the mains immediately. The damaged component must be replaced or repaired by RADWAG service directly. In case of any problems with correct operation of the scale, contact the closest manufacturer's service point.
  • Page 9: Mechanical Design

    1 - weighing pan, 2 - cross, 3 - load cell, 4 - base. 6.2. Multiple Load Cell Scales Multiple load cell TMX scale is intended to carry out fast and precise mass measurement of large loads. Its characteristic feature is a platform equipped with numerous load cells, usually four.
  • Page 10: Scales With Load-Cell Modules

    1 - weighing pan, 2 - load cells, 3 - feet. 6.3. Scales with Load-Cell Modules TMX scale with load cell modules is intended to carry out mass measurement of silos. The modules are built into construction of ground-fixed silo's support.
  • Page 11: Dimensions

    6.4. Dimensions For overall dimensions read product card of a respective scale, the product cards are to be found on RADWAG website www.radwag.pl. 6.5. Connectors Back PUE 5.15, PUE 5.19 board view Cable glands (x4pcs.) for load cell cable USB M12 4P connector...
  • Page 12: Connectors Topology

    Number of particular connectors may depend on weighing terminal current configuration. 6.6. Connectors topology Pin1 – B (RS485) Pin2 – RxD Pin3 – TxD Pin4 – A (RS485) RS232, RS485 Pin5 – GND Pin6 - +5VDC Pin7 – GND Pin8 – 12VDC Pin1 –...
  • Page 13: Technical Specifications

    Pin1 – IN1 Pin2 – IN2 Pin3 – IN3 Pin4 – IN4 4INPUTS Pin5 – COM Pin6 – 24VDC Pin7 – GND Pin8 – NC 6.7.2. Technical Specifications Output parameters Output quantity Output type Solid-state relay Cable cross-section 0.14 - 0.5 mm Maximum output current 0.5 A DC Maximum output voltage...
  • Page 14: Installation

     Remove transport locks and install the weighing pan: 7.1.2. Platform Scales: TMX.4.xx.C, TMX.4.xx.H, TMX.4.xx.H/Z Series  Take the device out of the packaging (pallet).  Place the device on a flat and even surface. Keep it away from any sources of heat.
  • Page 15: Track Scales: Tmx.2K Series

    The scale is installed on a rail of the load-bearing structure of the suspended track, the load cell is installed in a particular section of the track. The scale must be installed by an authorized RADWAG service exclusively, otherwise the warranty gets null and void.
  • Page 16: Levelling: 1-Load-Cell Platform Scales

    7.2. Levelling: 1-Load-Cell Platform Scales It is necessary to level the scale, do it by turning its feet. Keep turning the feet until the air bubble takes central position. 7.3. Levelling: 4-Load-Cell Platform Scales To level the platform use the levelling feet and the level indicator. Each foot can be turned left and right, turning causes tilt.
  • Page 17: Program Start-Up

    8.1. Program Start-up The program can be launched using the <PUE 5 Core> shortcut on the desktop. After starting the program, the main program window will be displayed. 8.2. Main Window The home page can be divided into 5 fields: ...
  • Page 18: Navigation In The Menu

     The on-screen functional buttons are showed below:  At the bottom of the screen you can see permanent functional buttons: 8.3. Navigation in the Menu Navigation in the menu is intuitive and user-friendly. Thanks to the touch screen display, it is very easy to use the program. Press the screen button or field in the screen to activate the assigned operate or function.
  • Page 19: Weighing

    Procedure:  Press button a couple of times to make the scale return to home screen.  Press in the lower bar to return to home page immediately. 9. WEIGHING Load the weighing pan. Read the result when stability marker is displayed. 9.1.
  • Page 20: Operation Conditions For Special Scales

    Avoid side loading, in particular side shocks. 9.2. Operation conditions for special scales It is forbidden to apply load other than intended for a particular scale:  beam scales; self-supporting, rigid load or load placed in rigid load- transferring packaging: ...
  • Page 21: Diagrams Of Connection Cables

     track scales (product hanging on a hook) intended to slide:  hooks suiting a particular track and scale,  smooth slide down the track, no jerky moves, no swinging left or right,  evenly loaded track. 10. DIAGRAMS OF CONNECTION CABLES Indicator - computer cable...
  • Page 22 Indicator - printer cable (EPSON) Indicator - printer cable (ZEBRA) USB adapter cable...
  • Page 23: Technical Specifications

    Indicator – barcode scanner cable (LS2208) „Scale-Ethernet” cable standard network cable terminated with RJ45 connectors on both ends. 11. TECHNICAL SPECIFICATIONS For technical specifications of respective scales go to RADWAG website www.radwag.pl. 12. ERROR MESSAGES...

Table of Contents