Operation Hints - Haier HSU-10HA03 - annexe 1 Operation Manual

Split air conditioner
Hide thumbs Also See for HSU-10HA03 - annexe 1:
Table of Contents

Advertisement

Installation
4.Piping Connection for Indoor Unit:
Insert the auxiliary hoses(liquid hose and gas hose)and the unit connection wires through the wall
hole from outdoor side,and connect the pipes and wires as per the method of piping connection, or
insert the auxiliary hoses(liquid hose and gas hose) and the connection wires as a whole through
the wall hole from indoor side for connecting the outdoor unit after connection of the auxiliary
hoses and unit connection wires.
5.Install and Fix:
Hang the indoor wall unit on the fastener of the mounting plate,
and move the unit left and right to check the firmness.
Hold the two sides of the unit with two hands to press the unit
to the mounting plate until a sound kacha
is heard.
Installation of Outdoor Unit
1.Install and Fix:
Fix the outdoor support on the wall with M10 expansion screws, then screw tightly the outdoor
unit on the support with M10 bolts and nuts, and leveled. If it is installed on wall or roof, the stand
shall be firmly fixed to resist the earthquake or strong wind. A vibration reduction rubber ring
shall be used.
2.Install the Drain Elbow
The elbow is only used for the thermal pump type air conditioner.And the cold air type air
conditioner does not need it.The elbow shall be installed as per the drawing.The drain elbow is not
used in a very cold weather(the air temperature is below 0
Piping Protective Cover
105
105
500
for long).
Drain Hose
Drain Elbow
28

Operation Hints

Air Conditioner Operation:
When the ambient humidity is too high,
the anion effect would be reduced, so during
the cooling and dehumidifying, water
would drop from the outlet mouth
3 Minutes Protection:
When the air conditioner is turned on immediately
after being turned off, the compressor will not start
until 3 minutes later to protect the machine.
Air Speed Change:
At the state of cooling, when air is set to
automatic ,
the air speed would decrease automatically when the room
temperature is close to the set temperature. In heating
mode, when the room temperature is the set temperature,
compressor will stop and fan will be low speed or stop;
In dehumidifying mode, air speed will change automatically.
Air Direction Adjustment
At the state of cooling or dehumidifying,
it would be better not to let the outlet guide plate
be downward for long, otherwise the outlet mouth
would be dew.
Healthy Operation
Only when the air conditioner is at the state of operation
(normal state), can the healthy operation be started.
When the button
Health
is pressed, the healthy operation
will be indicated.
Healthy Operation
Indication
Healthy Button
5

Hide quick links:

Advertisement

Table of Contents
loading