Trouble Shooting - Haier HSU-09LEA03-N - annexe 1 Operation Manual

Split type room air conditioner
Hide thumbs Also See for HSU-09LEA03-N - annexe 1:
Table of Contents

Advertisement

Trouble shooting

Before asking for service, check the following first.
Phenomenon
The system does not restart
immediately.
Noise is heard
Normal
Performance
inspection
Smells are generated.
Mist or steam are blown out.
In dry mode, fan
speed can't be changed.
Poor cooling
Multiple
check
T1:
Application temp. range of air conditioner -7
T3:
Application temp. range of air conditioner -7
7
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have
elapsed to protect the system.
When the electric plug is pulled out
and reinserted, the protection circuit
will work for 3 minutes to protect the
air conditioner.
During unit operation or at stop,
a swishing or gurgling noise may
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
generated by the casing expanding
or shrinking because of
temperature changes.
Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
This is because the system
circulates smells from the interior
air such as the smell of furniture,
paint, cigarettes.
During COOL or DRY operation,
indoor unit may blow out mist.
This is due to the sudden cooling
of indoor air.
In DRY mode, when room
temperature becomeslower
o
than temp.setting+2
C,unit will
run intermittently at LOW speed
regardless of FAN setting.
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
Is the air filter dirty?
Normally it should be cleaned
every 15 days.
Are there any obstacles before
inlet and outlet?
Is temperature set correctly?
Are there some doors or
windows left open?
Is there any direct sunlight
through the window during the
cooling operation?(Use curtain)
Are there too much heat sources
or too many people in the room
during cooling operation?
o
o
C~43
C.
o
o
C~54
C.
Cautions
The machine is adaptive in following situation
1.Applicable ambient temperature range:
For: T1
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
For: T3
Maximum: D.B / W.B
Indoor
Minimum: D.B / W.B
Cooling
Maximum: D.B / W.B
Outdoor
Minimum: D.B
Maximum: D.B
Indoor
Minimum: D.B
Heating
Maximum: D.B / W.B
Outdoor
Minimum: D.B / W.B
2. If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similar qualified person.
The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with a fuse
type T. 3.15A/250V.
If the fuse of outdoor unit on PC board is broken, please change
it with the type of T. 25A/250V.
4.The distance between the indoor unit and the floor should be
more than 2m.
5.The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached..
7.The used batteries should be disposed of properly.
8.The appliance is not intended to use by young children or infirm
persons without supervision.
9.Young children should be supervised ensure that they do not
play with the appliance.
10.The appliance must be installed on a strong enough support.
11.The wiring diagram is attached inside the machine.
o
o
Maximum: D.B / W.B 32
C/23
o
o
C/14
Minimum: D.B / W.B
18
o
o
Maximum: D.B
43
C/26
o
Minimum: D.B
18
C
o
C
Maximum: D.B
27
o
Minimum: D.B
C
15
o
o
24
C/18
Maximum: D.B / W.B
o
o
Minimum: D.B / W.B
-7
C/-8
C
o
o
29
C/19
o
o
18
C/14
o
o
54
C/24
o
18
C
o
27
C
o
15
C
o
o
24
C/18
o
o
-7
C/-8
C
C
C
C
C
C
C
C
C

Advertisement

Table of Contents
loading

Table of Contents