SPECIFICATIONS AND PURIFICATION DATA
Speci cations
Model
Color
Product Dimensions(W*D*H)(mm)
Dehumidifying Capacity
Power
Plug Type
Puri cation data
ITEM
Test laboratory
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
test method
Based on ANSI/AHAM AC-1-2020
suppression method
More negative ions are produced than positive ones, which can trap dust and bacteria
suppression target
Smoke、Dust、Pollen、PM2.5
test results
Smoke CADR(FT3/Min):51
Dust CADR(FT3/Min):64.2
Pollen CADR(FT3/Min):97.1
PM2.5 CADR(FT3/Min):57.2
230921139GZU-001
report number
ITEM
Test laboratory
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
test method
Based on:GB/T 18801-2022 GB 21551.3-2010
Technical Standard For Disinfection (2002 Ministry of Health P.R.China)-2.1.3
suppression method
Positive and negative ions produce positive and negative ions, positive and negative ion neutralization
discharge has a certain bactericidal ability
suppression target
Staphylococcus albicans 8032、Staphylococcus aureusATCC 6538、Escherichia coli 8099
test results
Staphylococcus albicans 8032 Killing Rate:99.95%
Staphylococcus aureusATCC 6538 Killing Rate:99.95%
Escherichia coli 8099 Killing Rate:99.95%
230921139GZU-002
report number
ITEM
Test laboratory
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
test method
Based on:GB/T 18801-2022 GB 21551.3-2010
Technical Standard For Disinfection (2002 Ministry of Health P.R.China)-2.1.3
suppression method
Positive and negative ions produce positive and negative ions, positive and negative ion neutralization
discharge has a certain bactericidal ability
suppression target
H1N1(A/PR/8/34)
test results
H1N1(A/PR/8/34) Killing Rate:99.99%
230921139GZU-002
report number
RAD-DIA17HK
White
420*265*662
MEELS Standard – 17L/Day (26.7℃ 60%)
Manufactory's Standard – 28L/Day (30℃ 80%)
AC 220V/50Hz
13A/250V
Puri cation
Sterilisation
Disinfection
Page 17
Need help?
Do you have a question about the RAD-DIA17HK and is the answer not in the manual?