Download Print this page

A.O. Smith Dual Coil Indirect Calorifier ITS-1000 Specification Sheet

A.o. smith dual coil indirect calorifier specification sheet

Advertisement

Quick Links

ITS
Dual coil indirect calorifi er
ITS - 300/400/500/600/750/1000
Indirect water heater (calorifi er) for a wide range of applications
• Single-wall spiral heat exchanger • PermaGlas® Ultra Coat™
second-generation glass coating technology prevents corrosion
• ITS 300: Three adjustable legs facilitate easy installation
• ITS 400-1000: Insulated ring base for easy installation
• Insulated access cover for comprehensive waterside maintenance
• Replaceable magnesium anode • Options: Flexible magnesium
anode for installation in confined areas • Powered anode for
reduced maintenance requirements • Temperature and pressure
valve with stainless-steel spring set to 95 °C and a maximum water
pressure of 7 bar • Analogue temperature gauge (0-120 °C)
• Electric element heat packs (3 - 36 kW) • Unvented kits
• Destratication pump kit
Innovation has a name.

Advertisement

loading

Summary of Contents for A.O. Smith Dual Coil Indirect Calorifier ITS-1000

  • Page 1 Dual coil indirect calorifi er ITS - 300/400/500/600/750/1000 Indirect water heater (calorifi er) for a wide range of applications • Single-wall spiral heat exchanger • PermaGlas® Ultra Coat™ second-generation glass coating technology prevents corrosion • ITS 300: Three adjustable legs facilitate easy installation •...
  • Page 2: Technical Specifications

    Technical specifications Technical data Output solar coil Surface area solar coil Water capacity solar coil Flow rate solar coil (80-60°C) Pressure drop solar coil mbar Output primary coil Surface area primary coil Water capacity primary coil Flow rate primary coil (80-60°C) Pressure drop primary coil mbar Maximum working pressure tank...
  • Page 3 Dimensions ITS 300 ITS 400-1000 1370 1705 2040 1835 2030 2000 1085 1087 1147 1127 1110 1277 1469 1387 1567 1487 1310 1652 1990 1797 1992 1962 1000 1000 1065 1035 1025 1360 1700 1485 1680 1600 1115 - Cold water Hot water Solar coil Primary coil...
  • Page 4: Installation Diagrams

    Primary return Over flow pipe Expansion vent pipe A.O. Smith unvented system kits utilise combination valves. Further installation and connection details can be found in the Installation & Commissioning Manual. For the parts numbers of components please refer to the...

This manual is also suitable for:

Dual coil indirect calorifier its-300Dual coil indirect calorifier its-400Dual coil indirect calorifier its-500Dual coil indirect calorifier its-600Dual coil indirect calorifier its-750Its 300 ... Show all