9.5 Table of alarms
Alarm
Description
E00
No alarm
Canister fill pump
E21
triac faulty
Triac "sensing"
circuit for the
E22
canister fill pump
faulty
Sensor signal fre-
E31
quency too high
Signal frequency
E32
of the sensor too
low
Appears in the
displaying of the
E33
last alarm, if posi-
tion 8 is NOT OK
Door closure
E45
sensor
Motor power triac
E51
short-circuited
Intervention of
E52
motor overheat-
ing safety cut-out
Motor triac "sens-
E53
ing" circuit faulty
Motor inopera-
E54
tional
Insufficient heat-
E61
ing (maximum
time exceeded)
Power relay to
E62
heater unit faulty
- ADL
Possible fault
---
Wiring faulty
Electronic board faulty
Electronic board faulty
Electronic board faulty
Wiring faulty
Damaged brushes / faulty
Electronic board faulty
Wiring faulty
Damaged brushes / faulty
Electronic board faulty
Door interlock faulty
Wiring faulty
Electronic board faulty
Motor faulty
Wiring faulty
Electronic board faulty
Motor faulty
Intervention of overheating safety cut-
out
Wiring faulty
Electronic board faulty
Electronic board faulty
Excessive wash load
Voltage too low
Motor/transmission system inopera-
tive
Heater unit faulty
Wiring faulty
NTC sensor faulty/out of place
Electronic board faulty
Heater unit faulty
Wiring faulty
Electronic board faulty
36/58
Action/machine status
---
Cycle interrupted
Cycle interrupted
Alarm activated only dur-
ing
diagnostics
Cycle interrupted
Alarm activated only dur-
ing
diagnostics
Cycle interrupted
Cycle interrupted
Power to the heater unit
and reversal of the direc-
tion of rotation are inter-
rupted. If the problem does
not re-occur, the alarm is
memorized and the cycle
continues; If, after several
attempts to restore power
(about 35 min.), the fault
persists, alarm E51 is gen-
erated
Cycle interrupted
Cycle paused after sev-
eral attempts at powering
the motor
Cycle paused
Forced cooling
circuit
Reset
command
---
OFF
OFF
---
OFF
---
OFF
OFF
OFF
OFF
Start
Start
OFF