Advertisement

Spectra Spot 40
Exterior Fixture
User Manual
Order code: LEDJ555

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spectra Spot 40 Exterior Fixture and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ledj Spectra Spot 40 Exterior Fixture

  • Page 1 Spectra Spot 40 Exterior Fixture User Manual Order code: LEDJ555...
  • Page 2: Safety Advice

    Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! • Before your initial start-up, please make sure that there is no damage caused during transportation. • Should there be any damage, consult your dealer and do not use the equipment. •...
  • Page 3: Ip Rating Information

    IP rating information PLEASE READ THE BELOW CAREFULLY BEFORE USING THE FIXTURE IN OUTDOOR/EXTREME ENVIRONMENTS IP Rating: The IP (International Protection) rating classifies and rates the degree of protection provided against intrusion of foreign objects such as dust and water into housings IP65 RATED and electrical enclosures.
  • Page 4 Product overview & technical specifications Spectra Spot 40 IP65 The Spectra Spot 40 is an IP rated LED pinspot, powered by a punchy 40W RGBW LED. The Spectra Spot features a tight 4.5° beam angle natively, an additional two frost lenses are also supplied expanding its versatility (10°...
  • Page 5: Technical Specifications

    Technical specifications 177mm 162mm 141mm 108mm In the box: 1 x fixture, 01 - 360° rotatable snoot 05 - Bracket 2 x frost filters 02 - Bracket tightening knobs 06 - Hydralock power input/output 1 x 5-Pin DMX cable 03 - OLED display 07 - Safety eye 2 x install bolts 04 - Function buttons...
  • Page 6: Installation

    Installation Before installing the fixture, the supporting structure (ie. truss) must be able to hold a minimum of 10 times the fixtures weight without any deformation (eg. 15kg - 150kg point load). The fixture must be secured with a secondary safety attachment when being installed (ie. an appropriate safety cable). Never stand directly below the fixture when mounting, removing, and/or servicing.
  • Page 7 Installation Installation: 1. Fasten the clamp to the fixtures bracket with a bolt and lock nut through one of the mounting holes. 2. Mount the fixture onto your truss system via the clamp and tighten to ensure secure. 3. Pull the safety cable through the fixture bracket and around the truss. www.prolight.co.uk Spectra Spot 40 User Manual...
  • Page 8 3 seconds. Main Menu Sub Menu Options/Values Description Software Update Please wait... Start-up display screen Fixture Information LEDJ Spectra Spot 40 V1. 01A Address 001-512 DMX Address Setting 4 (4 channel mode) 6 (6 channel mode) Channels DMX Channel Modes...
  • Page 9 Operating instructions Main Menu Sub Menu Options/Values Description 900Hz 1000Hz 1100Hz 1200Hz 1300Hz 1400Hz 1500Hz Refresh rate Refresh rate setting 2500Hz 4000Hz 5000Hz 10000Hz 15000Hz 20000Hz 25000Hz Display backlight Display Backlight Time Setting Display Lock Setting Locking (Press MODE 3s to unlock the screen) Password (password is 050) Calibrate...
  • Page 10 Operating instructions 4 channel mode: 6 channel mode: Channel Value Function Channel Value Function 000-255 Red dimmer (0-100%) 000-255 Red dimmer (0-100%) 000-255 Green dimmer (0-100%) 000-255 Green dimmer (0-100%) 000-255 Blue dimmer (0-100%) 000-255 Blue dimmer (0-100%) 000-255 White dimmer (0-100%) 000-255 White dimmer (0-100%) 000-255 Master dimmer (0-100%) 000-010 No function...
  • Page 11 Operating instructions 9 channel mode: Channel Value Function Channel Value Function 7 (cont.) Colour macros 000-255 Red dimmer (0-100%) 000-255 Green dimmer (0-100%) 179-184 Congo Blue 000-255 Blue dimmer (0-100%) 185-190 Surprise Pink 000-255 White dimmer (0-100%) 191-196 Fuchsia Pink 000-255 Master dimmer (0-100%) 197-202 Follies Pink 000-010 No function...
  • Page 12: Dmx Setup

    DMX setup Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address.
  • Page 13 DMX setup Notice: Be sure to follow the diagrams below when making your own cables. Pin Configuration Do not connect the cables shield conductor to the ground lug or 3-Pin 5-Pin allow the shield conductor to come in contact with the XLRs Pin 1 - Ground outer casing.
  • Page 14 Multiple fixture power linking Power linking: This fixture provides power linking via the power output on the rear allowing multiple units to be connected together. The maximum number of fixtures that can be connected is 30 fixtures @ 240V or 15 fixture @ 120V (including the first fixture). After the maximum number of fixtures are connected a new power run will need to be started.
  • Page 15: Weee Notice

    WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life.