5
Delivery, storage, transport
and installation
IMPORTANT
Damage to the housing and the unit components
due to heavy objects.
► Do not place any objects on the unit which are
heavier than 30 kg.

5.1 Scope of supply

NOTE
On delivery the accessories are enclosed in
two packages on the housing.
► Check delivery immediately after receipt for
outwardly visible damage and completeness.
► Notify supplier of any defects immediately.
The separate pack included contains:
Sticker with the unit number for attaching to page
3 of this manual
Control unit, consisting of the control, wall bracket
and masking plate
6-mm anchors with screws (2x each) for wall-
mounting the control unit
Safety valve, outdoor sensor
for units up to 12 kW capacity: Compression
fittings (2x)
for unit variant K, 14 kW capacity and higher:
Insulation material for venting valve on the cold
exchanger
for unit variant K, 14 kW capacity and higher:
Handle for cooling drain tap
Replacement material after dismantling the
module box:
● Insulation hoses (2x)
● Cable ties (4x)
● for units up to 12 kW capacity: O-rings (6x), flat
seal (1x)
● for units with 14 kW capacity and higher:
O-rings (8x)
Ball valves with filling and drain device:
● for units up to 12 kW capacity: 3x
● for units with 14 kW capacity and higher: 5x
10
Subject to change without notice | 83056700gUK – Translation of the original operating manual | ait-deutschland GmbH

5.2 Storage

► Where possible do not unpack the unit until
directly before installation.
► Store unit protected against:
● Moisture/damp
● Frost
● Dust and dirt
5.3 Unpacking and transport
NOTE
The module box can be removed for transport
( "Dismantle the module box", page 12).
Notes on safe transport
The housing with the unit components and the module
box are heavy ( "Technical data / Scope of supply",
from page 26). There is a risk of injuries or damage
to property if the housing with the unit components
falls or overturns or if the module box falls.
► The housing with the unit components and
module box must be transported and installed by
several persons.
► Secure the housing with the unit components
during transport. Carry the module box by the
carrying lugs.
There is a risk of cutting your hands on sharp edges
of the unit.
► Wear cut resistant protective gloves.
The hydraulic connections are not designed for
mechanical loads.
► Do not lift or transport the unit by the hydraulic
connections.
If the module box is tilted by more than 45°, compressor
oil runs into the cooling circuit.
► Do not tilt the unit with installed module box by
more than 45°.
Transport the unit preferably with a pallet truck,
alternatively with a handcart.
Transport with a pallet truck
► Transport the unit to the place of installation
packaged and secured on a wooden pallet.