Capnography Module (92517)
Quick Start Guide
NOTE: This reference guide is intended for a quick start of Capnography Module.
For detailed information, refer to the Clinical Parameters Operations
Manual.
P/N 073-0388-00 Rev C

Advertisement

loading
Need help?

Need help?

Do you have a question about the 92517 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Spacelabs Healthcare 92517

  • Page 1 Capnography Module (92517) Quick Start Guide NOTE: This reference guide is intended for a quick start of Capnography Module. For detailed information, refer to the Clinical Parameters Operations Manual. P/N 073-0388-00 Rev C...
  • Page 2 Spacelabs training acknowledgement The information in this document is copyrighted by Spacelabs Healthcare. You are granted a limited, non- exclusive, non-transferable, non sublicensable license to view the course, without any right to alter, modify, create derivative works, or publicly display the course material. Each course is intended to supplement, and not replace, the information provided in a product's operators manual and a clinician's use of good clinical judgment.
  • Page 3 Overview The 92517 Capnography Module is designed to measure the concentration of end-tidal CO and aid in determining the patient’s ventilatory, circulatory, and metabolic status. Features • Mainstream and Sidestream monitoring modes • Measurement of end-tidal CO , minimum CO , and Respiratory Rate •...
  • Page 4 • Use only genuine Masimo NomoLine capnography supplies, which are available through Spacelabs. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 5 The module uses specially designed airway adapters for adult/pediatric and infant patients and a CO2 sensor cable. Airway Adapters Adult/Pediatric or Infant Sensor Single use only Do not dispose. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 6 4. Allow the module to warm up for a minimum of 10 seconds. 5. Connect the airway adapter to the ventilator circuit. Mainstream port Sensor © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 7 The sidestream mode uses Masimo NomoLine capnography supplies, in high- or low-humidity designs. https://www.spacelabshealthcare.com/products/supplies/ for ordering information. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 8 Steady red light Sensor error Blinking red light Check sample line CAUTION: RED LIGHT, EITHER STEADY OR BLINKING, MAY REQUIRE REPLACEMENT OF THE NOMOLINE ADAPTER FILTER. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 9 4. Secure the integrated cannula (non-intubated) onto the patient or airway adapter (intubated) into the breathing circuit as directed by the instructions for use of the Nomoline device. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 10 3. Turn ON the alarm, select the setting and adjust with the arrows. Suspend CO sampling 1. Touch GAS  SETUP SUSPEND CO 2. Confirm YES The message Sampling Suspended shows on the display. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 11 • Not being monitored • Is receiving nebulized treatment. Note: Suspending the CO sampling during breathing treatments will extend the life of the NomoLine adapter filter. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 12 Appropriate compensation must be enabled to take accurate CO measurements when increased levels of O or N O are present in the airway. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 13 • Make sure that the gas reading and waveforms on the monitor are correct before you connect the airway adapter to the patient circuit. • Make sure that the patient circuit with the sensor is snapped firmly on the airway adapter. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 14 Warning: Do not breathe near the airway adapter or sampling line before or during the zeroing procedure to ensure the presence of 21% O and 0% CO © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 15 • Do not apply tension to the sensor cable. • Do not operate the CO sensor outside the specified operating temperature environment. © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...
  • Page 16 Clinical Parameters Operations Manual (P/N 070-2113-xx). Contact Information Technical Support: 1-800-522-7025 Available 24 hours a day and 7 days a week. Field Service Engineer: Clinical Education Consultant: Sales Representative: © 2024 Spacelabs Healthcare Quick Start Guide | Capnography Module 92517 P/N 073-0388-00 Rev. C...