Greentek PREMIER Series Installation, Operation And Maintenance Manual

Greentek PREMIER Series Installation, Operation And Maintenance Manual

Fresh air appliance

Advertisement

Available languages

Available languages

Quick Links

Manuel d'installation, de fonctionnement et de maintenance
PREMIER Series (PRS)
Fresh Air Appliance (FAA-HRV/ERV)
Appareil à air frais (AAF-VRC/VRE)
PARTS IN THE BOX
Heat/Energy Recovery Ventilator, 1 pc
Hanging Chain Kit, 1 pc
Hardware Kit, 1 pc
Drain Hose Kit, 1 pc
External Damper Wire harness, 1 pc
Operation and Installation Manual, 1 pc
PIÈCES DANS LA BOÎTE
Ventilateur récupérateur de chaleur/énergie, 1 pc
Kit de suspension, 1 pc
Vis et matériel d'assemblage, 1 pc
Tuyau d'évacuation, 1 pc
Faisceau de câbles de clapet externe, 1 pc
Manuel d'installation, 1 pc
Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of
such requirements, with the current edition of the National Building Code, and / or ASHRAE's "Good Engineering Practices".
Votre système de ventilation doit être installé conformément aux exigences de la province où vous habitez ou, à défaut de
telles exigences, conformément à l'édition actuelle du Code national du bâtiment du Canada ou aux « méthodes d'ingénierie
appropriées » de l'ASHRAE.
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 888.724.5211 • email info@greentek.ca
Greentek reserves the right to modify, at any time and without notice, any or all of its products' features,
designs, components and specifications to maintain their technological leadership position.
Please visit our website www.greentek.ca for more detailed technical information.
Greentek se réserve le droit de modifier partiellement ou entièrement, en tout moment et sans préavis, les
caractéristiques, la conception, les composants et les spécifications de ses produits, afin de conserver sa
position de leader de technologie.
S'il vous plaît visitez notre site siteweb www.greentek.ca pour des informations techiques plus détaillées.
Installation, Operation, and Maintenance Manual
Literature Item #: 463958
Rev Date: 2024-05-31
No. d'article de la littérature: 463958
Date de révision: 2024-05-31
PRS 1.5H
is not
ENERGY STAR
listed.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PREMIER Series and is the answer not in the manual?

Questions and answers

Ronald J Motz
March 16, 2025

Where are you able to purchase a external damper for 6 inch round duct & wire harness?

Subscribe to Our Youtube Channel

Summary of Contents for Greentek PREMIER Series

  • Page 1 50 Kanalflakt Way, Bouctouche, NB, E4S 3M5 Tel.: 888.724.5211 • email info@greentek.ca Greentek reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position.
  • Page 2 Note Warning/ Information Technical Practical tip Important information note PLEASE READ AND SAVE THESE INSTRUCTIONS Before installation careful consideration must be given to how this system will operate if connected to any other piece of mechanical equipment, i.e. a forced air furnace or air handler operating at a higher static pressure.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS DETERMINING YOUR AIRFLOW REQUIREMENT ........... . . 4 INSTALLATION EXAMPLES Fully dedicated system .
  • Page 4: Determining Your Airflow Requirement

    DETERMINING YOUR AIRFLOW REQUIREMENT Room Count Method Room classification Number of rooms CFM (L/s) CFM Required Master bedroom x 10 L/s (20 CFM) if yes add 10 L/s (20 CFM) Basement yes or no if no = 0 Bedrooms x 5 L/s (10 CFM) Living room x 5 L/s (10 CFM) Others...
  • Page 5: Installation Examples

    INSTALLATION EXAMPLES Suggested installation for: The way your fresh air appliance is installed can make a significant difference to the electrical energy you use. To minimize the electricity use of the fresh air appliance, a stand-alone fully ducted installation is •...
  • Page 6: Partially Dedicated System

    HRV/ERV is running at "Normal" speed. In the case of a multi-zone system, please contact Greentek customer service prior to installing any installation type requiring the use of the forced air system interlock.
  • Page 7: Simplified Installation

    HRV/ERV is running at "Normal" speed. In the case of a multi-zone system, please contact Greentek customer service prior to installing any installation type requiring the use of the forced air system interlock.
  • Page 8: Exterior Ducting Installation

    EXTERIOR DUCTING INSTALLATION WEATHERHOOD LOCATION OUTSIDE CORNER INSIDE CORNER • Decide where your intake and exhaust hoods will be located. 36" (1m) 36” (1m) Locating the Intake Weatherhood • Should be located upstream (if there are prevailing winds) from the 3' (900mm) exhaust outlet.
  • Page 9: Interior Ducting Installation

    INTERIOR DUCTING INSTALLATION • To maximize airflow through the ductwork system, all ducts should be kept short and have as few bends or elbows as possible. • 45º elbows are preferable to 90º. • Use “Y“ ducts instead of “T” ducts whenever possible. •...
  • Page 10: Hrv/Erv Installation

    HRV/ERV INSTALLATION LOCATION • For best performance, the space’s temperature should be above 54°F (12°C). At a minimum, the space must be above freezing temperatures. • Where servicing the product is convenient. • Near an exterior wall where the hoods will be mounted. •...
  • Page 11 INSTALLING DRAIN LINE Retrieve the drain fitting provided in the hardware kit of the HRV/ERV. Ensure the round rubber seal is on the flange of the fitting and insert them from inside the unit, thru the hole in bottom of the HRV/ERV, and hand tighten the plastic nut. Once the fitting is secured to the HRV/ERV, tighten the nut another half turn using a wrench to assure a better seal as shown in steps 1-3 below.
  • Page 12: Airflow Balancing

    Airflow balancing Fresh Balancing must be completed using the Greentek STS 2.0 HIGH HIGH HIGH Programmable Touch Screen Wall Control ENTERING BALANCING MODE Fresh Air Stale Air from Outside from Home In the options menu during the initial 5 second countdown sequence, long press on "ECO"...
  • Page 13: Wall Controls

    WALL CONTROLS * Please see instruction manuals for individual controls for proper wiring and set up of control systems. Installation of a user-accessible control with your product model will improve comfort and may significantly reduce the product model’s energy use 1.
  • Page 14 COMMANDES MURALES (SUITE) COMMANDE AUXILIAIRE – Ces commandes peuvent être associées à des commandes centrales ou combinées ensemble. (+ → + ; - → -) *Conserver la polarité entre la commande et le VRC SÉRIE T CARACTÉRISTIQUES RELIER À • Minuterie de 20/40/60 minutes avec trois voyant à DEL. •...
  • Page 15: Wiring Diagram

    WIRING DIAGRAM - PRS PRODUCT LINE...
  • Page 16 WIRING DIAGRAM (CONT'D) WIRING DIAGRAM TO Standard Accessory Control Contact Standard Furnace Interlock Wiring FURNACE THERMOSTAT TERMINALS FOUR WIRE TWO WIRE heating only FOR A FURNACE CONNECTION TO A COOLING SYSTEM: On some newer furnaces and older FURNACE thermostats, energizing the R and 24-VOLT TERMINAL BLOCK G terminal at the furnace has the...
  • Page 17: Control Hierarchy / Operations

    CONTROL HIERARCHY / OPERATIONS Terminal Block Label Description Remote off function (dry contact) – When S+ and S- terminals are shorted together, the ventilation product will be forced into standby mode until the dry contact is opened. Digital communication lines for four-wire controllers. ↓...
  • Page 18: Troubleshooting

    TROUBLESHOOTING Problem Causes Solutions Air is too dry Dehumidistat control is set too low Increase the desired level of humidity. Change ventilation mode from continuous mode to standby. HRV/ERV out of balance Have contractor balance HRV/ERV airflows Air is too humid Dehumidistat control is set too high Reduce the desired level of humidity.
  • Page 19: Hrv/Erv Maintenance Chart

    Check Drain Pan and Every 3 months Lines • The fans found in all Greentek HRV/ ERVs require no lubrication, and are Vacuum the Inside of the Annually factory balanced to prevent vibration Unit and promote silent operation.
  • Page 20 50 Kanalflakt Way, Bouctouche, NB, E4S 3M5 Tél.: 888.724.5211 • email info@greentek.ca Greentek se réserve le droit de modifier partiellement ou entièrement, en tout moment et sans préavis, les caractéristiques, la conception, les composants et les spécifications de ses produits, afin de conserver sa position de leader de technologie.
  • Page 21 Note Avertissement/ Information Information Conseil Note importante technique pratique VEUILLEZ LIRE ET CONSERVER CES INSTRUCTIONS Avant de procéder à l’installation, examinez avec soin la façon dont le système fonctionnera s’il est relié à tout autre appareil mécanique, notamment une fournaise à air pulsé ou un appareil de traitement d’air dont la pression statique est plus élevée.
  • Page 22 TABLE DES MATIÈRES DÉTERMINER VOS BESOINS DE VENTILATION ........... . . 23 EXEMPLES D'INSTALLATION Système entièrement spécialisé...
  • Page 23: Déterminer Vos Besoins De Ventilation

    DÉTERMINER VOS BESOINS DE VENTILATION Méthode compte de pièces Pi 3 /min (L/s) Liste des pièces Nombre de pièces PCM Required x 10 L/s (20 pi 3 /min) Chambre principale 3 /min Si oui, ajoutez 10 L/s (20 pi Sous-sol oui ou no Sinon = 0 x 5 L/s (10 pi 3 /min)
  • Page 24: Exemples D'installation

    EXEMPLES D'INSTALLATION Installation suggérée pour: La manière dont on a installé votre VRC/VRE peut faire une différence considérable quant à l’énergie • Plinthe à eau chaude électrique que vous utilisez. Afin de réduire la consommation d’électricité du VRC/VRE, on recommande •...
  • Page 25: Système Partiellement Spécialisé

    à air pulsé fonctionne et que dans la maison le VRC/VRE fonctionne à la vitesse "Normale". Dans le cas d'un système multi-zone, contacter le service à la clientèle de Greentek avant d'installer tout type d'installation nécessitant l'utilisation synchronisé d'un système à air pulsé.
  • Page 26: Installation Simplifiée

    "ÉQUILIBRAGE". Pendant la procédure d'équilibrage, assurez-vous que le ventilateur du système à air pulsé fonctionne et que le VRC/VRE fonctionne à la vitesse "Normale". Dans le cas d'un système multi-zone, contacter le service à la clientèle de Greentek avant d'installer tout type d'installation nécessitant l'utilisation synchronisé d'un système à air pulsé.
  • Page 27: Installation Des Conduits Extérieurs

    INSTALLATION DES CONDUITS EXTÉRIEURS EMPLACEMENT DES HOTTES Coin extéreur Coin intérieur OUTSIDE CORNER INSIDE CORNER • Décidez de l’emplacement des hottes d’aspiration et d’évacuation. 36po (1m) 36po (1m) 36" (1m) 36” (1m) Emplacement de la hotte d’aspiration • Doit être située en amont de la sortie d’évacuation (en présence de vents 3pi (900 mm) dominants).
  • Page 28: Installation Des Conduits Intérieurs

    Installation des conduits intérieurs • Pour maximiser le débit d’air dans le réseau de conduits, assurez-vous que tous les conduits sont le plus court et le plus droit possible. • Il est préférable d’utiliser des coudes de 45 degrés plutôt que des coudes de 90 degrés. •...
  • Page 29: Installation

    INSTALLATION EMPLACEMENT • Pour une meilleure performance, la température de l’espace devrait être maintenue au-dessus de 12 °C (54 °F). Au minimum, la température de l'espace doit être au-dessus du point de congélation. • Où l'entretien du produit est pratique. •...
  • Page 30 INSTALLATION DU TUYAU D'ÉCOULEMENT Récupérez le raccord de vidange fourni dans le kit de quincaillerie du VRC/VRE. Assurez-vous que le joint rond en caoutchouc est sur la bride du raccord et insérez-le depuis l'intérieur de l'unité, à travers le trou au bas du VRC/VRE, et serrez à la main l'écrou en plastique. Une fois le raccord fixé au VRC/VRE, serrez l'écrou encore un demi-tour à...
  • Page 31: Équilibrage

    ÉQUILIBRAGE L’équilibrage doit être réalisé à l’aide de la commande murale à écran tactile programmable Greentek STS 2.0. Fresh Ajustement des débits d'air HIGH HIGH HIGH ACCÉDER AU MODE D’ÉQUILIBRAGE Fresh Air Stale Air Dans le menu d’options, lors de la séquence de décompte...
  • Page 32: Commandes Murales

    COMMANDES MURALES * Veuillez consulter les manuels d’instructions des dispositifs de commande individuels pour connaître la bonne configuration de câblage et l’installation adéquate des systèmes de commande. 1. Assurez-vous que l’appareil n’est pas branché lorsque vous reliez la commande. Les raccords de câblage peuvent être retirés pour faciliter le branchement. COMMANDES CENTRALES Ceux-ci ne peuvent pas être utilisés avec une autre commande centrale (+ →...
  • Page 33 COMMANDES MURALES (SUITE) COMMANDE AUXILIAIRE – Ces commandes peuvent être associées à des commandes centrales ou combinées ensemble. (+ → + ; - → -) *Conserver la polarité entre la commande et le VRC SÉRIE T CARACTÉRISTIQUES RELIER À • Minuterie de 20/40/60 minutes avec trois voyant à DEL. •...
  • Page 34: Schémas Électriques

    SCHÉMAS ÉLECTRONIQUES...
  • Page 35 SCHÉMAS ÉLECTRONIQUES (SUITE) CONNEXION ÉLECTRIQUE Câblage standard de synchronisation avec une fournaise Standard Furnace Interlock Wiring À UNE FOURNAISE BORNES DU THERMOSTAT TERMINALS TERMINALS FOUR QUATRE FILS WIRE DEUX FILS TWO WIRE chauffage seulement heating only DANS LE CAS D'UNE FOURNAISE RACCORDÉE À...
  • Page 36: Hiérarchie / Opérations De Contrôle

    HIÉRARCHIE / OPÉRATIONS DE CONTRÔLE Étiquette de bornier Description Fonction d'arrêt à distance (contact sec) – lorsque les bornes S+ et S- sont court-circuitées, le produit de venti- lation est forcé en mode veille jusqu'à ce que le contact sec soit ouvert. Lignes de communication numériques pour contrôleurs à...
  • Page 37: Dépannage

    DÉPANNAGE Problème Causes Solutions L’air est trop sec – Le déshumidistat est réglé trop bas – Augmentez le niveau voulu d’humidité. Faites passer le mode de ventilation de « continu » à « attente ». – Le VRC/VRE est déséquilibré –...
  • Page 38: Tableau D'entretien Du Vrc/Vre

    à proximité du domicile de l'acheteur ou dans sa région. • Greentek se réserve le droit de fournir des pièces remises à neuf comme pièces de rechange. • Les frais de transport, de retrait et d'installation sont assumés par...
  • Page 39: Parts List

    PARTS LIST/LISTE DE PIÈCES PRS 1.5H PRS 2.0H PRS 1.5E PRS 2.0E BOM # Description (463920) (463921) (463922) (463923) Motor 428515 428515 428515 428515 MERV3, Electrostatic Filter kit 463939 463940 463939 463940 Heat/Energy Recovery Cell 463098 463097 463937 463938 Capacitor 6uF 411222 411222 411222...
  • Page 40 Greentek reserves the right to make technical changes. Greenteck se réserve le droit de faire des changements For updated documentation please refer to www.greentek.ca techniques. Pour de la documentation à jour, s'il vous plaît se référer au www.greentek.ca...

This manual is also suitable for:

Faa-hrvFaa-ervAaf-vrcAaf-vre

Table of Contents