ATESSRTF300/600 RectifierController SHENZHEN ATESS POWER TECHNOLOGY CO.,LTD U s e r M a n u a l GROWATT-ATESS Industrial Park, No.23 Zhulongtian Road, Shuitian Community, Shiyan Street, Baoan District, Shenzhen +86 755 2998 8492 info@atesspower.com www.atesspower.com Revised date: 2024-03-11...
Page 3
Caution!ElectricShockHazard ATESS will not notify users of any updates or revisions made to this manual. The content of the The device contains AC and DC power terminals. Disconnect manual will be continuously updated and amended; therefore, slight discrepancies or errors each power supply separately and wait for at least five with the actual product may occur.
The RTF installation and service personnel must undergo training to ensure their familiarity with The RTF device developed by ATESS converts AC electric energy from the grid or diesel the general safety regulations that need to be followed while working on electrical equipment.
Page 5
3.3Layoutofmainparts Implication 3.3.1Externalparts POWER When the RTF system is normally powered on, the indicator is steady on It is always bright when working normally.When a fault occurs, the The primary external components of the RTF consist of an LED indicator, an LCD touch screen, FUN/FAULT indicator blinks red.
Page 6
40K AC/DC module Mingwei power supply Supply power to the PCB Control the connection and disconnection between DC breaker(DC output) 3/12 the battery and RTF RTF300 Front Structure Reserve 220Vac outlet Socket Wiring terminals RTF terminals for external communication Parts name Instructions...
Page 7
RTF600 any defects or damages, immediate notification to the transportation company is required, 1204*1958*852mm 1204*1958*852mm Dimension(W*H*D mm) requesting an evaluation of the equipment. If necessary, assistance can be sought from ATESS. Weight(kg) 438kg 564kg Attention! The equipment should be stored exclusively in a package to ensure the prevention of internal dust and moisture.
ProductInstallation 5.1InstallationRequirements In order to ensure the normal operation of the machine, the installation environment and requirements are as follows: The RTF protection level is IP20, making it an electronic device that should not be placed in a humid location. It needs to be installed indoors away from direct sunlight and rain exposure; The installation site must meet the size requirements of RTF;...
Wiringspecification Otherprotection The RTF is suitable for installation in a dry and clean power station environment, with an IP20 The cables utilized in the system can generally be categorized into power cables and protection rating. However, it is important to take precautions to prevent water leakage from communication cables.
In order to ensure optimal protection of RIF during transportation, it is recommended to utilize appropriate packaging and adhere to the specified markings on the packaging. The graphical representation of these markings is as follows: Icon Hint Center of gravity mark Lifting mark Face up.
Page 11
Step 5: Crimp the wiring brass nose. Type RTF300/600 1. Place the stripped copper core part into the crimping hole of the copper nose. 2. Use a terminal press to press the copper nose tightly. The number of crimps should be at...
3. Use a hot hair dryer to tighten the heat shrink tubing. Step 6: Connect the "L1" cable to the "L1" or phase A (U) of the AC PDC. Select bolts that fit the 4851-A/B: Connect to the ATESS monitoring system and connect to Enerlog. wiring brass nose.
Page 13
5.7Parallelsystemwiring Parallelsystem: RTF300 and RTF600 can be used in parallel, and the maximum parallel number is 4. There are three circuit breakers inside the ATS, one is the BYPASS switch, and the other two are the GRID switch and the GEN switch. Pay attention to the cabinet label, do not connect to the wrong position, and pay attention to the three-phase phase sequence.
Poweronthemachineforthefirsttime Human-Machineinterface 6.1Checkbeforerunning 7.1IntroductiontoTouchScreen Before the RTF is put into operation, its installation shall be checked by at least two staff members Users can view RTF running information and set RTF running parameters on the LCD touch to ensure the correctness of the installation according to the items listed in the following table. screen.
Page 15
Switch status The status of the current switch RTF model: Model Settings. Set 1, indicating that the model is RTF300. Set 2, stands for RTF600. RTF 485 addr: The communication address of machine 485, which is used to identify Enerlog.
Page 16
See Attached Table 7.3 for more common fault information. DC outout Overvoltage (A) : DC outout overvoltage protection point. The maximum value is 1000A for the RTF600 and 500A for the RTF300. DC output power(kw) : Set the maximum power of the machine. The maximum value is the 7.3LCDDisplayInformationSchedule...
If the parameters need to be confirmed due to system abnormalities, please modify the parameters under the guidance of ATESS after-sales personnel! 8.2GeneralTroubleshooting If a fault occurs during the operation of the machine, please click on the LCD "History Information"...
Page 18
8.3Shutdownandpower-offProcedure 3. RTF overtemperature load loss:occurs when the actual temperature reaches the set value Solution: Warnings! a. Check the temperature display on the screen to confirm the current temperature. After the RTF is completely powered off, the RTF is still live, if you need to b.
ModuleDescription 9.3FrontPanelOperationInstructions 9.1ModuleOverview 9.3.1LEDDisplayPanel The UR100040-SW charging module is composed of three-phase active PFC, DC/DC conversion, It can display charging module voltage, current, fault code, address, packet number, auxiliary power supply, input and output detection and protection circuits. The CAN bus realizes communication protocol, operation mode and other information.
Page 20
220V, output current 5A, address 2, group number 1, running in automatic mode to repair, but contact ATESS after-sales personnel. or manual mode, press ▲ or ▼ will be shown in the following figure 6.
ProductMaintenance Causeoffailure(faultcode) Handlingsuggestions Name Status EEPROM failure 10.1RoutineMaintenance Fan drive failure 10.1.1Maintenanceandrepair Bright Internal over-temperature Return for repair (E02) Primary side and secondary Fault All maintenance and repair operations on the RTF can only be performed when s i d e c o m m u n i c a t i o n i s indicator the RTF is safely disconnected from all external connections, when it is abnormal...
The RTF needs to be powered off during the process of replacing the air filter. 11.1ProductSpecifications How to replace the air filter: The dust filter cotton on the door panel can be directly extracted upward for cleaning and ModelNumber RTF300 RTF600 replacement. ACparameters Power rating...
Page 23
11.2ATESSfactorywarranty WarrantyPeriod The warranty period of this product is three years, if otherwise stipulated in the contract, the contract shall prevail. During the warranty period of time energy technology products, customers should take the initiative to show to the service personnel of Time Energy Technology company during maintenance Invoice and date of purchase of the product.