Maintenance And Inspection - Omron ZX-E Datasheet

Smart sensors zx-e series
Hide thumbs Also See for ZX-E:
Table of Contents

Advertisement

Calculating Unit
When using a Calculating Unit, connect the linear output ground of
the corresponding Amplifier Unit.
Connectors
Do not connect or disconnect connectors while the power is ON.
Be sure hold to connectors by the cover when connecting or discon-
necting.
Mounting
Handling
When mounting the Sensor Head, do not apply excessive shock by,
for example, using a hammer. Doing so may result in damage or a re-
duction in the level of water-proofing. Also, there are screw-shaped
models that require a toothed washer to allow for a tolerance in the
tightening torque for the nut.
When using a heat-resistant model like the ZX-EM02HT, develop de-
signs that account for thermal expansion due to rising sensing object
temperature so the sensing object will never touch the sensing sur-
face. Also note that any sudden rise in temperature will shorten the
service life of the product.
Tightening Torque
Do not apply excessive torque when tightening the nut. Use a toothed
washer if necessary.
Model
Tightening torque
ZX-EM02T
15 N·m
ZX-EM07MT
ZX-EM02HT
59 N·m
Note:
The above figure applies for use with a toothed washer.
Mounting Cylindrical Models:
Tighten set screws with a tightening torque of 0.2 N·m max.
A
Set screw hole
Model
ZX-EDR5T
9 to 18 mm
ZX-ED01T
ZX-ED02T
11 to 22 mm
Installation Location
Do not install the product in the following locations.
• Locations subject to temperatures outside the specified range
• Locations subject to condensation due to sudden temperature
changes
• Locations subject to humidity levels outside range 35% to 85%
• Locations subject to corrosive or flammable gases
• Locations subject to dust, salts, or metallic powder.
• Locations directly subject to vibrations and shocks
• Locations subject to direct sunlight
• Locations subject to splashes of water, oil, or chemicals
• Locations subject to strong electromagnetic or electrical fields

Maintenance and Inspection

• Be sure to turn OFF the power supply before adjusting or removing
the Sensor Head.
• Cleaning:
Do not use thinners, benzine, acetone, or kerosene for cleaning.
ZX-E Series
10
Mounting Bracket
Y92E-F5R4 (for 5.4-dia.
screws), sold separately
A
Smart Sensors (Inductive Displacement Type)

Advertisement

Table of Contents
loading

Table of Contents