Communication Interface Specifications - Omron ZFX-C10 - COMMUNICATION Command Reference Manual

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10 - COMMUNICATION:
Table of Contents

Advertisement

Communication Interface Specifications

You can use the USB port or RS-232C/422 connector of the Controller to perform serial communication with
external devices such as a personal computer or programmable controller.
Serial communication functions in the RUN mode. Communication cannot be performed in the ADJ or MENU
modes.
<USB>
This interface allows Full speed (12 Mbps) communications compliant with USB2.0 with a PC equipped with
the same USB interface.
Synchronization method Start-stop
Transmission code
Communication speed
Data length
Parity
Stop bit
Delimiter
Transmission protocol
<RS-232C/422>
This interface allows data communications compliant with the EIA RS-232C/422 standards up to a maximum
speed of 115200 bps.
Synchronization method Start-stop
Transmission code
Communication speed
Data length
Parity
Stop bit
Delimiter
Transmission protocol
For details on how to set the communication specifications, refer to the User's Manual.
<Ethernet>
Communication protocol TCP/IP
Transmission mode
2
Communication Interface Specifications
ASCII (Binary format can be selected only when outputting measurement values set at
[Setup] - [Support] - [Calculation] - [Data].)
USB2.0-compliant
-
-
-
CR, LF, CR+LF
Normal (Note, however, that XMODEM protocol is used when sending image data, system
data and other data.)
ASCII (Binary format can be selected only when outputting measurement values set at
[Setup] - [Support] - [Calculation] - [Data].)
9600, 19200, 38400, 57600, 115200
7 bits, 8 bits
None, even, odd
1 bit, 2 bits
CR, LF, CR+LF
Normal (Note, however, that XMODEM protocol is used when sending image data, system
data and other data.)
Peer to Peer