Download Print this page
Omron G3F Manual

Omron G3F Manual

Solid state relays

Advertisement

Quick Links

Solid State Relays G3@-VD
G3F/G3FD
Refer to Warranty and Application Considerations (page 1), Safety
Precautions (page 4), and Technical and Safety Information (page 6).
International Standards for G3F Series,
Same Profile as MY Power Relays
• Shape-compatible with mechanical relays.
• Certified by UL, CSA, and VDE (model numbers with a suffix of
"-VD").
• Socket type, same size as MY Power Relays.
• Operation indicator provided to confirm input (model numbers
with "N" before the suffix).
Model Number Structure
Model Number Legend
G3F-@@@@@-@
2 3 4 5 6 7
1
1. Basic Model Name
G3F:
Solid State Relay
2. Rated Load Power Supply Voltage
2:
200 VAC
3. Rated Load Current
02:
2 A
03:
3 A
4. Terminal Type
S:
Plug-in terminals
G3FD-@@@@-@
2
3 4 5 6 7
1
1. Basic Model Name
G3F:
Solid State Relay
2. Load Power Supply Type
D:
DC
3. Rated Load Power Supply Voltage
X:
50 VDC
1:
100 VDC
4. Rated Load Current
02:
2 A
03:
3 A
214
Solid State Relays G3@-VD
5. Zero Cross Function
6. Operation Indicator
7. Certification
5. Terminal Type
6. Operation Indicator
7. Certification
G3F/G3FD
Blank:
Equipped with zero cross functions
L:
Not equipped with zero cross function
Blank:
Not equipped with operation indicator
N:
Equipped with operation indicator
VD:
Certified by UL, CSA, and VDE
S:
Plug-in terminals
Blank:
Not equipped with operation indicator
N:
Equipped with operation indicator
VD:
Certified by UL, CSA, and VDE

Advertisement

loading

Summary of Contents for Omron G3F

  • Page 1 International Standards for G3F Series, Same Profile as MY Power Relays • Shape-compatible with mechanical relays. • Certified by UL, CSA, and VDE (model numbers with a suffix of “-VD”). • Socket type, same size as MY Power Relays. • Operation indicator provided to confirm input (model numbers with “N”...
  • Page 2: Ordering Information

    Indicator Rated output load Rated input voltage Model function Photocoupler 3 A at 100 to 240 VAC (See note 1.) 5 to 24 VDC G3F-203SN-VD 2 A at 100 to 240 VAC (See note 1.) 100/110 VAC G3F-202SN-VD 200/220 VAC Phototriac coupler 3 A at 100 to 240 VAC (See note 1.)
  • Page 3 72 k 150 VAC max. 40 VAC min. G3F-203S-VD 4 to 24 VDC 3 to 28 VDC 15 mA max. (See note.) 3 VDC max. 1 VDC min. G3F-203SL-VD 5 VDC 4 to 6 VDC 4 VDC max. 12 VDC 9.6 to 14.4 VDC...
  • Page 4 Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Destruction: 1,000 m/s Ambient temperature Operating: –30 C to 80 C (with no icing or condensation) Storage: –30 C to 100 C (with no icing or condensation) Ambient humidity...
  • Page 5: Engineering Data

    203SL-VD G3FD-102SN-VD/102S-VD G3FD-X03SN-VD/X03S-VD Ambient temperature ( C) Ambient temperature ( C) One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3F-203SN-VD/203S-VD/202SN-VD/ G3FD-X03SN-VD/X03S-VD G3FD-102SN-VD/102S-VD 203SLN-VD/203SL-VD Energized time (ms) Energized time (ms)
  • Page 6: Safety Precautions

    SSR to an inrush absorber (varistor). ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K055-E1-05 In the interest of product improvement, specifications are subject to change without notice.

This manual is also suitable for: