Download Print this page

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

loading
Need help?

Need help?

Do you have a question about the 8101-PIV and is the answer not in the manual?

Questions and answers

Summary of Contents for Keithley 8101-PIV

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 The 8101-PIV test fixture is a metal case with four female triaxial connectors (SMU1–4), two SMA connectors (AC+DC IN 1–2) and a latch on the outside (see Figure 1). Inside the test fixture are two 4-pin device holders (transistor sockets) and two plungers for parts with 2 leads.
  • Page 3 Model 8101-PIV Test Fixture User’s Guide Figure 1 – Test fixture Latch Outer shield Inner conductor Inner conductor Braided shield Inner shield conductor PA-917 Rev. B / November 2006...
  • Page 4: General Definitions

    Model 8101-PIV Test Fixture User’s Guide General definitions The types of product users are: Responsible body is the individual or group responsible for the use and maintenance of equipment, and for ensuring that operators are adequately trained. Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of the instrument.
  • Page 5 Model 8101-PIV Test Fixture User’s Guide Model 4200-SCS NOTE The current leakage specifications depend upon a clean fixture. Avoid contamination that could cause degraded performance and increase current leakages beyond specified limits. To operate and use with the 4200-SCS: 1. Install device (2, 3, or 4 terminal) on the SMU device holder (see transistor socket, Figure 3).
  • Page 6 Model 8101-PIV Test Fixture User’s Guide Figure 2 - 4200-SCS mainframe connection scheme (transistor socket) “Force” Connectors on SMUs 8101-PIV Test fixture SMU 1 SMU 4 SMU 2 SMU 3 Pin 1 Pin 4 Pin 2 Pin 3 SMU Device Holder...
  • Page 7 Channels Model Description Model 2602 Source Measure Instrument* Figure 4 2600-DEMO-TRX Cable* 8101-PIV Test Fixture Model 2602 Source Measure Instrument* Figure 4 2600-DEMO-TRX Cable* 8101-PIV Test Fixture *Not supplied with Model 8101-PIV text fixture. PA-917 Rev. B / November 2006...
  • Page 8 Model 8101-PIV Test Fixture User’s Guide Figure 4 - Single Model 2602 connection scheme (2 channels) SMU B SMU A CHANNEL A CAT I CAT I CHANNEL B SMU Output Connection Strain Relief Model 2600-DEMO-TRX Model 2600-DEMO-TRX 1.0 M 8101-PIV...
  • Page 9 Model 8101-PIV Test Fixture User’s Guide Figure 4 - Single Model 2602 connection scheme (2 channels) CHANNEL A CHANNEL A CAT I CAT I CAT I CAT I CHANNEL B CHANNEL B Model 2600-DEMO-TRX 1.0 M (4 places) LO not connected...
  • Page 10 Model 8101-PIV Test Fixture User’s Guide PIV device holder operation WARNING There can be hazardous voltages exposed in this test fixture and risk of electric shock. Do not touch internal electrical connections. Remove all sources of power before opening cover and changing devices.
  • Page 11: Handling And Cleaning

    The Model 2600-DEMO-TRX is an SMU Output to Triax Connector Adapter cable providing HI and LO outputs. Use this cable to connect SMU outputs to triax connectors on the 8101-PIV Test Fixture. Figure 4 - Single Model 2602 connection scheme (2 channels)