Omron E3X-SD Series Brochure
Omron E3X-SD Series Brochure

Omron E3X-SD Series Brochure

Simple fiber amplifiers
Hide thumbs Also See for E3X-SD Series:

Advertisement

Simple Fiber Amplifiers
E3X-SD/NA Series
Simplicity and High Performance
The Series now includes models with digital displays and direct key setting.
Digital Display – Direct Key Setting
NEW
Bar Display – Manual Setting

Advertisement

Table of Contents
loading

Summary of Contents for Omron E3X-SD Series

  • Page 1 Simple Fiber Amplifiers E3X-SD/NA Series Simplicity and High Performance The Series now includes models with digital displays and direct key setting. Digital Display – Direct Key Setting Bar Display – Manual Setting...
  • Page 2 High Performance Operation and Displays So Simple That Anyone Can Use the Amplifier Right Away A design that focuses on simple operation has resulted in an Amplifier that is so simple it can be operated without the manual. The Amplifier also uses a large, easy-to-read operation indicator and a simple display for excess gain (i.e., incident level/operating level).
  • Page 3 (25,000 counts per second for the E3X-NA@F). Optical Communications to Prevent Mutual Interference for Up to Five Amplifiers Optical communications is used between Amplifiers. Interference is reliably prevented for up to five Amplifiers by mutually staggering the light emission timing (except for the E3X-NA@F). Up to...
  • Page 4 Selecting Fiber Amplifiers Simple For simple operation: Select a Simple Fiber Amplifier. Digital display and direct setting Bar display and adjuster setting Reliable Intuitive Standard Amplifiers E3X-SD@ E3X-NA@ Fastest in class Super-high-speed Amplifiers (20 µs) E3X-NA@F Water-resistant Amplifiers (IP66) E3X-NA@V All in One For multifunctional capability: Select an Advanced Fiber Amplifier.
  • Page 5: Ordering Information

    E3X-SD/-NA The Standard for Fiber Amplifiers with Simple Operation and High Performance ■ Operation so simple that essentially anyone can use the amplifier right way. ■ Immediately determine operation and amount of light with a simple, bright display. ■ General-purpose capabilities to simply handle a broad range of applications.
  • Page 6 E3X-CN11 (3-wire) E3X-CN12 (1-wire) Standard separately) models E3X-NA6 E3X-NA8 Refer to the following tables when placing an order. When Using 5 Amplifier Units 5 Amplifier Units 1 Master Connector + 4 Slave Connectors Sensor I/O Connectors (Order Separately) Size Cable specifications...
  • Page 7: Ratings And Specifications

    50 V 20 mΩ max. (20 mVDC max., 100 mA max.) Contact resistance (The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) Number of insertions...
  • Page 8 Cores Cladding 20 mm A large number of ultrafine cores are all surrounded by cladding. As a result, the fiber is flexible and can be bent without significantly reducing the light intensity. This helps solve problems, such as fiber being broken by getting caught on other objects.
  • Page 9 E32-T11F 1050 Environment resistive E32-T12F 1600 Chemical models E32-T14F resistant E32-T51F E32-T81F-S E32-T51V E32-T51V + E39-F1V Vacuum E32-T54V resistant E32-T54V + E39-F1V E32-T84SV For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E354).
  • Page 10 4 to 10 E32-L16 0 to 15 0 to 13 E32-D51 Environ- Heat resistant E32-D81R/E32-D61 ment E32-D73 resistive E32-D12F models Chemical resistant E32-D14F For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E354).
  • Page 11: I/O Circuit Diagrams

    (D-ON) transistor Operate Load (relay) *Not present on the E3X-NA. Reset (Between blue and black leads) Note: Timing Charts for Timer Settings (T: Set Time) ON delay OFF delay Incident light Incident light No incident light No incident light L-ON...
  • Page 12: Safety Precautions

    3. Do not attempt to disassemble, repair, or modify the Caution product. 4. Do not apply voltage or current in excess of the rated Do not exceed the rated voltage. ranges. Excess voltage may result in malfunction or 5.
  • Page 13: Precautions For Correct Use

    Remove the Protective Cover and raise the lock lever to pull ● Mounting out the fiber. DIN Track Mounting/Removal Mounting Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN track. Protective Cover Unlocked Locked 2. Slide the Amplifier Units together, line up the clips, and Note:To maintain the fiber properties, confirm that the lock is press the Amplifier Units together until they click into place.
  • Page 14 Master and Slave Connectors that are not connected to underneath the clip. other Connectors. 1. Insert the clip to be removed into the slit underneath the clip on another Amplifier Unit. Sticker Sticker Note: Attach the stickers to the sides with grooves.
  • Page 15 22.4 34.8 Mounting bracket (E39-L143) (Order separately) Two, 3.2-dia. holes Stainless steel (SUS304) 22.4 *1. The mounting bracket can also be used on side A. *2. There is no hole for E3X-NA@F models. Amplifier Units with Connectors Operation indicator E3X-SD6...
  • Page 16 23.9 Mounting bracket (E39-L148) (Order separately) Stainless steel (SUS304) Two, M3 *1. The mounting bracket can also be used on side A. *2. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.45 mm , Insulator diameter: 1.1 mm), Standard length: 2 m.
  • Page 17 Four, R1.7 10.3 10 max. Material: Stainless steel (SUS304) End Plates M4 × 8 PFP-M 11.5 panhead screw M4 spring washer 35.5 35.3 For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E354).
  • Page 18: Operating Procedure

    Excess gain level display light Approx. Sensitivity Setting 110% to 120% The sensitivity can be set with the UP and DOWN Keys similar to using an adjuster knob. The sensitivity can also be easily Unstable Approx. incident light or set by using the following three teaching functions.
  • Page 19 WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.
  • Page 20 This document provides information mainly for selecting suitable models. Please read the Instruction sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. OMRON Corporation OMRON ELECTRONICS LLC...