Page 1
Operating Instructions U1KT002 Distance Sensor Translation of the original operating instructions Subject to change without notice Available as PDF file only Version 2.0 www.wenglor.com...
The safety precautions and warnings are laid out in accordance with the following principle: SIGNAL WORD Type and source of danger! Possible consequences in the event that the hazard is disregarded. à Measures for averting the hazard. 1 ‒ General | U1KT002 ‒ Distance Sensor...
• wenglor assumes no liability for printing errors or other inaccuracies contained in these operating in- structions unless wenglor was verifiably aware of such errors at the point in time at which the operat- ing instructions were prepared.
• All rights are reserved by wenglor. • Commercial reproduction or any other commercial use of the provided content and information, in particular graphics and images, is not permitted without previous written consent from wenglor. 1 ‒ General | U1KT002 ‒ Distance Sensor...
• The product is not suitable for use in potentially explosive atmospheres. • The product may be used only with accessories supplied or approved by wenglor, or in combination with approved products. A list of approved accessories and combination products can be found at www.wenglor.com on the product detail page.
Read the operating instructions carefully before using the product. Protect the sensor against contamination and mechanical influences. Approvals and Protection Class IND. CONT. EQ 72HL / E189727 For use in class 2 circuits 2 ‒ For Your Safety | U1KT002 ‒ Distance Sensor...
1106,71 a Output Function in Default Setting Output function Pin 2 Output function Pin 4 Switching function Pin 2 Switching function Pin 4 * Relative to switching distance, at least 2 mm 3 ‒ Technical Data | U1KT002 ‒ Distance Sensor...
Some technical data depend on the mode set. Depending on the setting, the following data are obtained: Reflex-Mode Operation Filter value Switching frequency in Hz Response time in ms 20.4 23.8 27.2 30.6 37.4 40.8 44.2 47.6 54.4 57.8 57.8 57.8 57.8 1,000 2,000 0.15 3,000 3 ‒ Technical Data | U1KT002 ‒ Distance Sensor...
Measurement of the sonic cone on a rod with a diameter of 25 mm Characteristic curves show the position of the center or the front edge of the measured object (Ø 25 mm rod) at the time of switching. 3 ‒ Technical Data | U1KT002 ‒ Distance Sensor...
Standard sonic cone (front edge of the measured object) INFORMATION Please note that using multiple ultrasonic sensors can cause reciprocal influence. Housing Dimensions Dimensions specified in mm (1 mm = 0.03937 Inch) 3 ‒ Technical Data | U1KT002 ‒ Distance Sensor...
6a = switching status indicator, O2 Complementary Products wenglor offers you the right connection and mounting technology as well as other accessories for your product. You can find this at www.wenglor.com on the product details page at the bottom. Layout ①...
• Protect the product against exposure to direct sunlight. NOTICE Risk of property damage in case of improper storage! The product may be damaged. à Storage instructions must be complied with. 4 ‒ Transport and Storage | U1KT002 ‒ Distance Sensor...
à Comply with installation instructions. CAUTION Risk of personal injury or property damage during installation! Personal injury and damage to the product may occur. à Ensure a safe installation environment. 5 ‒ Installation and Electrical Connection | U1KT002 ‒ Distance Sensor...
To this end, the sensor is connected to a suitable IO-Link master (see product detail page/complementary products). The interface protocol and the IODD can be found at www.wenglor.com in the download area for the respective product. For information on installing and connecting the wTeach2 software and its structure, as well as information on the general functions, see the wTeach2 operating instructions.
3. Set the sonic cone to narrow at the receiver, in order to detect even small objects between the emit- ter and the receiver. INFORMATION Sensors in reflex and through-beam mode must not be combined! 6 ‒ Settings | U1KT002 ‒ Distance Sensor...
The response time of the sensors is extended in synchronous mode to 1.9 × response time normal mode (e.g. filter 0: response time normal mode = 17 ms; response time synchronous mode = 32 ms). 6 ‒ Settings | U1KT002 ‒ Distance Sensor...
2. Permanently disconnect pin I/O2 or connect it to 0 V. 3. The sensor is protected against inadvertent changes caused by the teach-in key. Error Output The error output is switched in the following cases: 6 ‒ Settings | U1KT002 ‒ Distance Sensor...
Performance in the event of con- Read-out in accordance with filter Continuous changes to the fill- response time level are read out immediately. tinuous changes (continuously valid distance value) 6 ‒ Settings | U1KT002 ‒ Distance Sensor...
Cleaning and inspection of the plug connections at regular intervals are advisable. Do not clean the sensor with solvents or cleaning agents that could damage the product. The product must be protected against contamination during initial start-up. 7 ‒ Maintenance Instructions | U1KT002 ‒ Distance Sensor...
Proper Disposal wenglor sensoric GmbH does not accept the return of unusable or irreparable products. Respectively valid national waste disposal regulations apply to product disposal. 8 ‒ Proper Disposal | U1KT002 ‒ Distance Sensor...
Declarations of Conformity Declarations of conformity can be found on our website at www.wenglor.com in the product’s separate download area. 9 ‒ Declarations of Conformity | U1KT002 ‒ Distance Sensor...