Advanced blood pressure monitors with ecg (30 pages)
Summary of Contents for Trister TS 330BPS
Page 1
SMART UPPER ARM BLOOD PRESSURE MONITOR TS 330BPS Model: User Manual Please read this user manual carefully before opera�ng the device. Kindly keep it safe for future reference.
Page 2
Dear Trister Smart User, Thank you for choosing Trister Smart Automatic Upper Arm Blood Pressure Monitor TS 330BPS. This user manual provides important information to help you operate this device accurately. Before using this product, please read the user manual thoroughly and carefully.
Page 3
IMPORTANT SAFETY INSTRUCTIONS READ BEFORE USE The following basic safety precautions should always be taken. 1. Use device only for the intended use as described in this manual. 2. Do NOT use the device if it is not working properly or damaged. 3.
TABLE OF CONTENTS INTRODUCTION Intended Use Principle Meter Overview Display Screen HOW TO INSTALL AND UPDATE THE MbH BP BLOOD PRESSURE MANAGER Installing Updating BLUETOOTH PAIRING IMPORTANT INFORMATION ABOUT PERFORMING A BLOOD PRESSURE TEST Before Measurement Proper Measurement Position HOW TO TEST YOUR BLOOD PRESSURE Taking Measurement with the Device Itself Measuring with MbH BP Blood Pressure Manager App MAINTENANCE...
INTRODUCTION Intended Use Trister Smart Automatic Upper Arm Blood Pressure Monitor TS 330BPS is specially designed to measure the systolic, diastolic blood pressures and also your rate by using a non-invasive technique in which an inflatable cuff is wrapped around the upper arm.
HOW TO INSTALL AND UPDATE THE MbH BP BLOOD PRESSURE MANAGER You can use the Trister Smart Automatic Upper Arm Blood Pressure Monitor TS 330BPS alone or with the MbH BP Blood Pressure Manager App. MbH BP Blood Pressure Manager is designed to assist you in easily monitoring, recording, and tracking of your blood pressure.
BLUETOOTH PAIRING You can easily transfer your data from the meter to your devices via Bluetooth. Please contact your local distributor for assistance. Please note that you must complete the pairing between meter and Bluetooth receiver before transmitting data. Please refer to the images on the quick start guide for detailed procedures.
IMPORTANT INFORMATION ABOUT PERFORMING A BLOOD PRESSURE TEST Before Measurement before measurement. could be longer if necessary, depending on your physical condition. your blood pressure on the same arm. Applying the Cuff 1. Stretch your left/right arm with your palm facing up.
24~43cm 9.4”~16.9” 4. Press the hook material firmly against the pile material. The top and bottom edges of the cuff should be tightened evenly around your upper arm. NOTE: The blood pressure monitor is fixed onto the cuff. Do NOT remove the cuff or change to other different sized cuff.
HOW TO TEST YOUR BLOOD PRESSURE Taking Measurement with the Device Itself Always apply the pressure cuff before turning on the meter. 1. Tap ON/OFF Button. All the LCD symbols will appear with a long “beeping” sound. Then the cuff will begin to inflate automatically. 2.
Measuring with MbH BP Blood Pressure Manager App All the screenshots displayed below are from the display screen of the Bluetooth receiver installed with MbH BP Blood Pressure Manager App and not from the display screen of the meter. Single Measurement 1.
Page 14
5. After measurement, the screen displays systolic, diastolic pressures and pulse rate. If the measurement is initiated via the app, you will also see a curve diagram below the pulse rate. The diagram is only available when the measurement is initiated via the app rather than by the meter’s ON/OFF button.
Page 15
The “ ” (in green) will turn into “ ” (in red) on the app during measurement. If you want to stop the measurement, press “ ” (in red) to terminate it, and the meter will be switched off. 4. After the first measurement is complete, the device and MbH BP Blood Pressure Manager app will start counting down before the second measurement begins.
MAINTENANCE Low Battery Signal The meter will display either of the two messages below to alert you when the meter power is getting low. 1. The symbol appears along with display messages: The meter is functional and the result remains accurate, but it is time to change the batteries.
• Replacing the batteries does not affect the test results stored in memory. After battery replacement, please pair the meter with your mobile device again to synchronize time and date, so measurements taken afterwards will be stored in memory with correct time and date. Caring for your meter To avoid the meter from attracting dirt, dust or other contaminants, wash and dry your hands thoroughly before use.
ADDITIONAL DETAILED INFORMATION Reference Values Clinical studies show that adult diabetes is often accompanied by elevated blood pressure. People with diabetes can reduce their heart risk by managing their blood pressure along with diabetes treatment* Monitoring your routine blood pressure trend helps you to know your body condition.
SYSTEM TROUBLESHOOTING Error Messages on Meter PROBABLE MESSAGE SOLUTION CAUSE Please contact local customer error. service for help. correctly. Relax and repeat Blood pressure the measurement. If error measurement error. still remains, contact local customer service for help. Review the instructions and repeat the test.
Troubleshooting POSSIBLE CAUSE WHAT TO DO Batteries exhausted. Replace the batteries. Batteries incorrectly installed or Check that the batteries are absent. correctly installed. POSSIBLE CAUSE WHAT TO DO Movement during measurement. Repeat measurement. Measurement taken just after Rest for at least 30 minutes exercise.
SYMBOL INFORMATION SYMBOL REFERENT Consult instructions for use Type BF applied part Manufacturer Temperature limit Serial number CE mark 0123 IP22 Resistant to liquid ingress Humidity limitation Caution Authorized representative in the European Community RoHS Compliance This device does not belong to household waste and must be returned to a collection point for recycling electric and electronic devices according to local laws.
SPECIFICATIONS System Performance Model No.: TS 330BPS Size of Meter w/o Cuff: 145 (L) x 64.5 (W) x 29.6 (H) mm, 240 g Power Source: Four 1.5 V AAA alkaline batteries Power Saving: Automatic power off if system idle for 3 minutes...
EMC - DECLARATION OF CONFORMITY Manufacturer’s declaration-electromagnetic emissions The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance RF emissions CISPR 11...
Page 24
Manufacturer’s declaration-electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such and environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance Conducted RF Not applicable...
Page 25
Manufacturer’s declaration-electromagnetic immunity Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Test Maximum IMMUNITY...
Warranty Information Trister warrants that the Trister Smart Automatic Upper Arm Blood Pressure Monitor TS 330BPS alone should be free of defects in materials and workmanship under regular use without damage for a period of three years since the date of purchase.
Page 27
TaiDoc Technology Corporation MedNet EC-REP GmbH B1-7F, No. 127, Wugong 2nd Rd., Wugu Dist., 24888 New Taipei City, Taiwan For any further information, comments or 0123 suggestions you can write to us at info@trister.com or visit...
Need help?
Do you have a question about the TS 330BPS and is the answer not in the manual?
Questions and answers