  • Page 1 User Manual V1.0...
  • Page 2 IMPORTANT SAFETY INFORMATION -Only charge the device at temperatures ranging between 0°C and 55°C. -The battery capacity decreases when operated in a cold ambient tem- perature. This is not a fault and occurs for technical reasons. Environmental influences -The recommended temperature for using this product is -25° to +55°. WARNING! Never point the lens of the device directly at intense heat -Temperature exceeding this range will affect the service life of the sources such as the sun or laser equipment.
  • Page 3 For further information and safety instructions, please refer to the Opera- may be imposed for the improper disposal of this type of waste. tion Manual provided. This is also available on our website in the down- For business customers within the European Union load center: www.infirayoutdoor.com.
  • Page 4 -Test to see if the device displays a clear, undisturbed image. -Check that the settings for the device are correct. See the notes in the section Operation. Observation with and without glasses Thanks to the flexible eye-shade, the GEMINI series can be used with or without glasses.
  • Page 5: Specifications

    Specifications ±1(3-100m); Measuring Accuacy,m ±(1+L×0.25%)(100-1200m,L is the distance to the target) Eyepiece Focal Length of Eyepiece,mm 12.5 Model GEL35R GEH50R Magnification, × Thermal Imaging Specifications Resolution, pixel 384×288 640×512 Eye Relief, mm Pixel Size, μm Eye Relief Diameter, mm ≤25 ≤25 Diopter Adjustment, D NETD, mk...
  • Page 6: Package Contents

    √ Full color fusion Package Contents Image Capture and Video/Au- √ dio Recording √ Video Playback Wi-Fi Transmission √ (ios & android) √ Electronic compass 1.Shockproof 2.Neck Strap 3.Type-C Cable Carrying Case √ Microphone √ 940nm Infrared Flashlight Power supply, data export, firrmware update Type-C interface Other Specifications 5.18650 Battery...
  • Page 7: Product Overview

    Product Overview Main Functions  Image capture, recording, and video playback GEMINI series binocular have integrated high-sensitivity thermal imaging  Wi-Fi image transmission detector, laser range finding, Wi-Fi, DMC, microphone and 1024×768  PIP, Hot Track , Fusion, Infrared highlight, Infrared edging OLED.
  • Page 8: Product Appearance

    (1)Eye cup (11)Infrared lens Product Appearance (2)Eyepiece (12)Lens Cap (3)Down Button (13)Microphone (4)Menu Button (14)Interpupillary Distance Adjustment (5)Up Button (15)Infrared Focus Ring (6)Camera Button (16)Neck strap buckle (7)Range finding Button (17)Battery Compartment (8)Power Button (18)Digital night vision Focus Ring (9)Laser Range Finding Window (19)Type-C Interface (10)Digital night vision Lens (20)Tripod Interface...
  • Page 9: Button Descriptions

    Button Descriptions Button Operation Functions No menu:Standby/Wakeup Short press With menu:exit/return Power Button Hold for 1.5s Power on/off Short press Single range finding Range Finding Button Long press Start/ End continuous range finding Image capture Short press Camera Button Start/stop video recording Long press No menu:E-zoom cycles through 1×~4×, step 1×...
  • Page 10: Types Of Power Supply

    Types of Power Supply  Type 1:Insert two 18650 batteries into the binocular following the below illustration, pay attention to the polarity. Figure 4 Power supply via Type-C Cable  The nominal voltage and current is 7.4V/0.4A with battery as power supply, and the nominal voltage and current is 5V/0.6A when powered via Type-C cable.
  • Page 11 Mounting of IR Illuminator Quick Start Guide  The IR illuminator with wavelength of 850nm or 940nm can be mounted Power device on: Long press the power button(8)for 1.5 secs, the on the binocular in lowlight conditions and in the darkness. starting logo will be displayed on the screen after 1 second.
  • Page 12 Quick Menu: On the home screen, short press the menu button (4) to  button (8) to cancel during shutdown count down. open quick menu, then the WiFi, DMC, Microphone, Hot Track and IR Enhance can be set. Short press Up button (5)/Down button (3) to toggle among the different function options and short press the menu button (4) to switch parameters, short press the power button (8) to exit/back to the previous level.
  • Page 13: Status Bar

    Status Bar Figure 8 Standby Interface Figure 9 Main Interface 1.Time and date: display the current time and date. It can be modified in System Menu→ System Settings→ Time Settings. 2.Image Mode: short press the Down button (3) to switch among White- hot, Blackhot, Redhot and Iron.
  • Page 14 4.Image Scenarios:In NV Mode,short press the Down button (3) 11.Battery level:real-time battery level display,display when the +Menu button (4),switch between Day and Night In IR Mode, battery level is low,display when no battery is inserted. long press the Down button (3)+Menu button (4),switch among 12.Azimuth: display the current azimuth information in real time.
  • Page 15: Image Calibration

    Up button (5) +Menu shutter calibration, you can try to icon flashes below the status bar and time in the InfiRay Outdoor button (4),the device will close the infrared lens cap and in the upper left corner of the...
  • Page 16: Digital Zoom

    appears on the bottom right Video Recording  On the home screen, long press corner of the screen.  the Camera button (3) to start Photos are stored in the built-in the video recording function. storage.   Then, the recording timer in the When “the memory space is format of the HH: MM: SS (hour: insufficient”...
  • Page 17: Fusion Settings

    Fusion Settings DMC Zero Declination Angle Settings  Short press the Up button (5) + visual image rightward/down-  During the installation or transporta- Down button (3) to enter fusion ward by one step. tion of the DMC, there may be a settings interface.
  • Page 18 4.Hot Track: short press the menu Quick Menu Functions button (4) to enable hot track, which will make real-time track on the  On the Home Screen,short hottest object on the screen mark press the Menu button (4) to with a 32*32 red box, disabled by enter the quick menu.
  • Page 19: System Menu Functions

    adjustment on IR/NV image System Menu Functions contrast, adjustment range 1-5, 3 by default, supported in IR or NV  On the Home Screen, long press mode. the Menu button (4) to enter the 4.Reticle: the reticle will be system menu. displayed on the screen center Figure 22 Image Selection Interface ...
  • Page 20 (3)to switch image/video, short  Short press Up button (5)/ Video Browse Short press Up button (5)/ Down  press power button (8) to return Down button (3) to select Play, button (3) to select the video, to the previous menu. then short press menu button (3)...
  • Page 21 2.Waterproof Overlay:When this procedures are as shown in the set, as shown in the following setting range is 1-32 characters, following figure: function is enabled, date, DMC, and figure: the initial name is GEMINI_the ranging distance information will be latter six characters of Mac, for displayed on local recorded videos, example: GEMINI_78C132.
  • Page 22 first.As shown in the following cannot be recovered after restoring 2.Time zone settings:time zone System Settings can be set, local time zone is figure: system, all the parameters will displayed by default. 4.Restore system:the image and restore to factory default settings, 3.Time settings:it can be used video data will be deleted and so please backup first.As shown in...
  • Page 23 12345678.  When Wi-Fi is successfully connected, it supports to control the device via the InfiRay Outdoor App downloaded in the mobile device. Setting Wi-Fi Name and Password Figure 47 System Info Figure 46 Storage Info The name and password of the Wi-Fi in GEMINI series can reset on the 2.
  • Page 24: Firmware Update

    Notifications about updates will be posted on the official website or  It needs to reboot the device to take the new name and password social media or InfiRay Outdoor APP. effect.  Connect the PC to the device via Type-C cable, and open the USB Note: If the device is reset to the factory settings, the name and flash drive on the PC.
  • Page 25: Technical Inspection

    Wi-Fi in real time mode.   The condition of the object lens and eyepiece (there should be no You can find the detailed instruction about InfiRay Outdoor at the site cracks, greasy spots, dirt or other deposits). www.infirayoutdoor.com. ...
  • Page 26: Legal And Regulatory Information

     Check the glass surface of the eyepiece and lens. If necessary, clear This device complies with part 15 of the FCC Rules. Operation is subject off the dust and sand on the lens (it is perfect to use a non-contact to the following two conditions: (1) This device may not cause harmful method).
  • Page 27 interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver.

This manual is also suitable for:

Gemini geh50r

Table of Contents