Installation into a Rack without Threaded Screw Holes
Procedure
To install a chassis in a rack without threaded screw holes:
Repeat the process for each POTS splitter chassis. POTS splitter chassis can be
mounted directly on top of each other.
Installation into a Rack with Threaded Screw Holes
Procedure
To install a chassis in a rack with threaded screw holes:
Repeat the process for each POTS splitter chassis. POTS splitter chassis can be
mounted directly on top of each other.
5910-A2-GZ40-00
The number of POTS splitters required. The 5910 POTS splitter supports up to
192 DSL lines.
NOTE:
Install chassis in the rack from the bottom up to maintain stability.
1. Install the mounting brackets appropriate for your rack.
2. Determine where the chassis will be placed in the rack. Mark the rail where the
four holes in the mounting brackets will be.
3. Slide a self-retaining nut onto each marked rail hole and align the hole of the
nut with the hole in the rail.
4. Line up the chassis mounting brackets with the self-retaining nuts.
5. Holding the chassis in place, loosely install the bottom screws first and then
the top screws.
6. Tighten all screws firmly using a Phillips screwdriver.
1. Install the mounting brackets appropriate for your rack.
2. Determine where the chassis will be placed in the rack.
3. Line up the chassis mounting brackets with the rail holes.
4. Holding the chassis in place, loosely install the bottom screws first and then
the top screws.
5. Tighten all screws firmly with a Phillips screwdriver.