● When it is in the parameter settings page, the mode, fan
speed, and switch buttons are invalid.
● Parameter C14 allows you to return to the home screen after
pressing "
".
Parameter
Parameter Name
Code
C00
Main and
secondary wired
controller setting
C01
Cooling only/cooling
and heating setting
C02
Power failure memory
function setting for
the wired controller
C03
Time to remind
users to clean the
filter on the wired
controller
C04
Settings for infrared
receiver of wired
controller
C05
Whether indoor
ambient temperature
is displayed
C06
LED indicator of
wired controller
Parameter
Default Value
Range
0 indicates the main
0
wired controller and
1 indicates a
secondary wired
controller
00: Cooling and
00
Heating
01: Cooling Only
00: None
00
01: Available
00/01/02/03/04
01
00: Disable
01
01: Enable
00: No
00
01: Yes
00: Off
01
01: On
34
Remarks
If two wired controllers control one IDU,
addresses for two wired controllers must be
different. You are not allowed to set IDU
parameters via the secondary wired controller
(address 1), but can set the wired controller.
Heating mode is not available in cooling only
setting
For a two-way wired controller, this
parameter is used to store the status of
Follow Me.
00: No reminder to clean filter
01: 500h,
02: 1000h
03: 2500h
04: 5000h
When "Disable the infrared receiver of the
wired controller" is on, the wired controller
cannot receive remote control signal.
When it is on, LED indicator shows the
on/off state of the indoor unit.
When it is off, LED indicator is off.