Check operation

E
9.
Plug the
power supply cord
into the grounded
outlet.
flow tester
air intake
flow tester
edge of line
on flow tester
front of cooktop
10.
Check for proper venting:
• Check that the air filter is in place.
• Align the dotted line labeled for "cooktop
models" on the flow tester with the edge
of the intake on the left side of the cooktop
near the center.
• Turn on the downdraft system:
If the card is pulled into the air intake,
your downdraft is working properly.
If the card is not pulled into the system,
see "Venting requirements," Pages 3-4,
and check duct installation for possible
causes.
Electronic ignitions system
Cooktop burners use electronic ignitors in
place of standing pilots. When the cooktop
control knob is turned to the "LITE"
position, the system creates a spark to light
the burner. This sparking continues until the
control knob is turned to the desired setting.
Check operation of right-side surface
burners module
11.
Push down and turn
each surface burner
control knob to
"LITE" position. The
flame should light within
4 seconds. Turn the control
knob to "HI" position after
burner lights. Do Not leave the knob in the
"LITE" position after burner lights.
Check each surface burner for
proper flame at "HI" setting. The
small inner cone should have a
very distinct, blue flame that is
1/4" (0.6 cm) to 1/2" long (1.3 cm).
The outer cone is not as distinct as
the inner cone. Turn surface
burner control knobs to "OFF" position.
screw
air
shutter
to
close
air
opening
to
open
If surface burner flames need adjusting –
• Remove burner grate and burner pan.
• Turn control knob to "HI" position.
• Loosen the air shutter screw. Adjust the air
shutter to the widest opening that will not
cause the flame to lift or blow off the burner.
• After adjusting air shutter, tighten air shutter
screw.
• Turn control knob to "OFF" position.
• Replace burner grate and burner pan.
• Repeat if necessary for other surface burner.
Page 6
12.
burner control knob to "LITE" position and
then to "LO" position. The low flame should
be a minimum, steady blue flame.
Do Not use a metal blade to pry off control
knob; this could damage the product. If the
control knob cannot be easily removed, tuck
a cloth under the knob and pull upward on
cloth with steady, even pressure to remove
knob.
counterclockwise
to increase flame
valve stem
If the low flame needs adjusting –
• Remove the control knob and turn the
adjustment screw in the center of the valve
stem. Do Not turn screw more than 1/2
revolution in either direction.
• Replace the control knob. Check the
adjustment by turning the control knob from
"HI" to "LO" several times. The burner is
properly adjusted when the low flame
remains steady and the burner does not go
out.
• Turn control knob to "OFF" position.
• Repeat if necessary for other surface burner.
Check operation of left-side surface
burners or optional grill module
13.
left-side surface burner or optional grill
module.
Surface burners module: Push in and turn
right surface burner control knob to "LITE"
position. The flame should light within
4 seconds. Turn the control knob to "HI"
position after burner lights. Do Not leave the
knob in the "LITE" position after burner
lights.
Check surface burner for proper
flame. The small inner cone will be
similar to the right-side module
surface burner flames, but will be
shorter and softer. The outer cone is
not as distinct as the inner cone.
Turn surface burner control knob to
"OFF" position.
Repeat for left surface burner control knob.
Grill module: Remove grill grates and burner
pan. Push in and turn right control knob to
"LITE" position. The flame should light within
4 seconds. Turn the control knob to "HI"
position after burner lights. Do Not leave the
knob in the "LITE" position after burner
lights.
Check the grill burner for proper flame. The
small inner cone will be similar to the right-
side surface burner flames, but will be shorter
To adjust
and softer. The outer cone is not as distinct as
surface
the inner cone. Turn grill burner control knob
burner air
to "OFF" position.
shutter
Repeat for left grill burner control knob.
surface burner
air shutter
Push in and turn each surface
clockwise to
reduce flame
Use module instructions to install
air
opening
air
shutter
If burner flames need adjusting –
• Remove surface burner grates and burner
pan.
• Push in and turn control knob to "LITE"
position and then to "HI" position.
• The right air shutter controls the front half
of the burner; the left air shutter controls
the rear half. Insert a screwdriver blade in
the air shutter slot that needs adjusting
and lightly twist the screwdriver to slide
air shutter backward or forward to adjust
the flame. Adjust the burner air shutter to
the widest opening that will not cause the
flame to lift or blow off the burner.
• Turn control knob to "OFF" position.
• Repeat if necessary for other burner
control knob.
14.
Push in and turn each control
knob to "LITE" position and then to "LO"
position. The low flame should be a
minimum, steady blue flame.
If low flame needs adjusting –
• Remove the control knob and turn the
adjustment screw in the center of the
valve stem. Do Not turn screw more than
1/2 revolution in either direction.
• Replace the control knob. Check the
adjustment by turning the control knob
from "HI" to "LO" several times. The
burner is properly adjusted when the low
flame remains steady and the burner does
not go out.
• Turn control knob to "OFF" position.
• Repeat if necessary for other burner
control knob.
• Replace surface burner grates and burner
pan or grill grates and burner pan.
You have just finished installing
your new downdraft cooktop.
To get the most efficient use
from your new cooktop,
read your Use & Care Guide.
Keep Installation Instructions
and Guide close to cooktop
for easy reference.
To adjust
grill burner
air shutter
grill burner
air shutter

Advertisement

Table of Contents
loading