INSTALLATION GUIDE BR550 / BR552 BRW650 / BRW652 BRB750 / BRB752 Under our policy of continuous product development, product specifications may change without notice. Please refer to the online version of the manual for the latest updates and specifications. www.schweigen.com.au...
1. Welcome Thank you for purchasing your new Schweigen exhaust fan system. To get the maximum output from this unit, please read through this operating guide before use and installation. The operating guide contains important information on the correct use and maintenance of the unit, as well as important safety notes.
We recommend this appliance to be installed or repaired by an experienced Home Appliances technician. Please see our website www.schweigen.com.au for experienced installers. It is dangerous to modify any part of this appliance. Modification of any kind, will immediately void the warranty.
2. Your Safety This manual is for the installation of the motor systems use for bathroom and general extraction. Motor Features • Universal mounting all position with IP23 degree of weather protection • Patented anti water intrusion system. • Acoustic dome with super quiet, long vane centrifugal fan. •...
Any installation problems must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation. Faulty installation may void warranty. An experienced installer list can be obtained from the Schweigen website www.schweigen.com.au or call 1300 881 693.
3. Description BR550, BRW650, BRB750 Included in the box: 1. Motor system (350W x 295H mm approx.) Approx. 3 metre, 10amp cable and standard plug (backdraft shutter and weather shield included) 2. Fire resistant 200mm metal pipe 3. Flexible ducting. Approx. 4 metres, 200mm (210mm outside dimension) diameter 4.
For more information on environmental noise limit and conditions please contact your local Council. For installation, We have a list of experienced installers available on the Schweigen website. Do not install duct in a straight line and a minimum of two gentle bends in the ducts is required.
Page 9
4. Installation Weather shield attachment Weather shield Backdraft Shutter Power Cord 50mm 200mm Metal Pipe Dektite (not supplied) Fix fan module using side locking screw Fit side supports to locate pipe Clamps/Straps to supports Connect to NOTE: Prevent any cord bunching by bathroom pulling cord through from plug top end vent...
220-240V supply Wall cover plate (optional)** * With through wall installations flap shaft will be close to vertical. ** Optional parts are available from Schweigen, please contact 1300 881 693. Figure 2 Wall installation IMPORTANT It is a requirement to use the wall hanging bracket for all wall mount installations.
Page 11
4. Installation 200mm metal pipe Wall hanging bracket Weather shield upper most Locking Screw 200mm ducting Motor Min 55mm Cord slots at bottom (6 o’clock position) NOTE: Ensure that power cord is fed through exit slot and is not allowed to double back restricting motor inlet.
Incorrect installation may reduce airflow and increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen will take no responsibility for problems caused by faulty installation. Installation must be carried out by an experienced installer.
5. Flexible Ducting Shallow Roof Space In shallow roof spaces, do not crush or kink flexible ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 6. 90 degree curve PVC or galvanise curve Figure 6 Shallow roof space...
5. Flexible Ducting Securing Flexible Duct Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be supported by using gaffer or electrical tape. Provided that it does not restrict the internal diameter of the ducting.
6. Maintenance Roof Restoration or Cleaning Before roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact. IMPORANT Any damages caused by the use of chemical products are not covered by warranty. Figure 8 Avoid chemical contacted to motor system Page 16...
7. Measurements BR550, BR552 - Diffuser ø200 ø228 ø300 ø317 Hold diffuser against board Toggle clip snaps and push upwards into place holding diffuser firmly The cone in the middle can be adjusted to increase or reduce airflow by winding...
7. Measurements BRB750, BRB752 - Diffuser Two timber support batons by installer 196mm outlet Ceilling 251 x 251 312 x 312 Plaster in edge strip Page 19...
It is not the responsibility of Schweigen Home Appliances to rectify any incorrect installations. A service call out fee will be charged for any Schweigen technician that attends a call, whereby it is established that the fault is due to an incorrect installation or non-manufacturing fault. Should the appliance be installed in such a way that the service agent is unable to gain access to the appliance, the person/s who own the premises where the appliance resides —...
Page 24
Australia 4/1-5 Lake Drive, Dingley Village, Victoria 3172. Phone 1300 881 693 Email sales@schweigen.com.au Web www.schweigen.com.au New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510 Email info.parex@emerson.com Web www.parex.co.nz SCH00015...