Viking C-200 Technical Practice

Basic single entry phone interface

Advertisement

TECHNICAL
TECHNICAL
T
T
E
L
E
E
L
E
The C-200 allows single line telephones or a
telephone system to share a phone line with a
single Viking entry phone. Tenants may answer
an entry phone call and converse with the visitor.
The C-200 provides a "Call Waiting" tone when
the phone line is in use.
Tenants may call out to the entry phone for mon-
itoring purposes. Auxiliary contacts are provided
to operate a doorbell, or activate a camera,
lights, etc.
If additional features (such as doorstrike, multiple entry phones with caller ID, and key-
less entry) are needed, use the Viking model C-2000A.
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• Allows single line telephones or a telephone system
to share a phone line with a door entry phone
• House phones ring with C.O. line cadence or
distinctive ring when the entry phone "Call"
button is pressed
• Compatible with these Viking entry phones:
- E-10A, E-20B, E-30, E-35, E-40 and E-50 Phones
- K-1500-7 Stainless Steel Panel Phone
- Or use with any analog phone
• Provide entry phone activated chimes and whole
house paging when used with a Viking model
SLP-1 Single Line Paging Controller
• Produces double "Call Waiting" tones if the entry
phone is activated when the house phones are
already on a call
• One set of normally open and normally closed
contacts available for operating a doorbell,
camera, lights, etc.
• Add door strike capability with the Viking model
RC-2A Remote Touch Tone Controller
i
n
f
o
@
v
i
k
i
n
g
e
l
e
c
t
i
n
f
o
@
v
i
k
i
n
g
e
l
e
c
S
S
C
O
M
O
L
U
T
I
O
N
S
C
O
M
O
L
U
T
I
O
N
S
Add a Viking Entry Phone to an
Existing Phone Line
r
o
n
i
c
s
.
c
o
m
t
r
o
n
i
c
s
.
c
o
m
P
r
a
c
P
r
a
c
2
1
C
2
1
C
F
O
R
T
H
E
S
T
F
O
R
T
H
E
S
T
A
p
p
l
i
A
p
p
l
i
• Add an entry phone to your standard home or
office phones to provide door communication
• Provide commercial or residential security via
two-way handsfree communication at the door
or gate
• Connects in series with a single phone line or
to a phone system's unused line input (loop
start trunk input)
h
t
t
p
h
t
t
p
S
p
e
c
S
p
e
c
Power: 120VAC / 13.8VAC 1.25A, UL listed adapter provided
Dimensions: 133mm x 104mm x 44mm (5.25" x 4.1" x 1.75")
Shipping weight: 0.9kg (2 lbs.)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95%
non-condensing humidity
Contacts: .5A @ 125V AC, 1A @ 30V DC
Ring Output: 5 REN, capable of ringing (10) 0.5 REN phones
Auxiliary Power Output: 12VDC @ 300mA maximum
Talk Battery: 32V DC
Connections: (12) cage clamp screw terminals
C-200
C-200
Basic Single Entry
t
i
c
e
t
i
c
e
Phone Interface
E
N
T
U
R
Y
E
N
T
U
R
Y
Need More Information on the C-2000A?
?
Call (715) 386-4345 and select 156.
c
a
t
i
o
n
s
c
a
t
i
o
n
s
P
h
o
n
e
.
.
.
P
h
o
n
e
.
.
.
:
/
/
w
w
w
.
v
i
k
i
n
g
e
l
e
:
/
/
w
w
w
.
v
i
k
i
n
g
e
l
i
f
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
July 19, 2007
7
1
5
.
3
8
6
.
8
8
6
1
7
1
5
.
3
8
6
.
8
8
6
1
c
t
r
o
n
i
c
s
.
c
o
m
e
c
t
r
o
n
i
c
s
.
c
o
m

Advertisement

Table of Contents
loading

Summary of Contents for Viking C-200

  • Page 1 TECHNICAL TECHNICAL The C-200 allows single line telephones or a telephone system to share a phone line with a single Viking entry phone. Tenants may answer an entry phone call and converse with the visitor. The C-200 provides a “Call Waiting” tone when the phone line is in use.
  • Page 2: Returning Product For Repair

    The following procedure is for equipment that has failed out-of-box (within 10 days of purchase): 1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recom- mended tests for diagnosis.
  • Page 3: Simplified Schematic

    Adapter included * Earth Ground (optional) C.O. / Phone Line Input Analog Trunk Line Input of a Phone System MODEL C-200 © VIKING ELECTRONICS HUDSON, WI 54016 SINGLE ENTRY PHONE CONTROLLER 1 2 3 4 5 8 9 10 11 12 EARTH C.O.
  • Page 4 B. Add Paging, Music-On-Hold, and Loud Ringing with a Viking SLP-1 For more information and installation instructions on the SLP-1, retrieve Fax Back Document 478. VIKING MODEL SLP-1 © PREAMP VOLUME VIKING ELECTRONICS HUDSON, WI 54016 SINGLE LINE PAGING CONTROLLER...
  • Page 5 D. Using the C-200 on an Unused Trunk / Line Input The C-200 can also be used without a phone line. This is ideal for connecting the C-200 to an unused trunk/phone line of a phone system, or connecting to phones used only for door communications.
  • Page 6: Auxiliary Relay

    Aux Relay is activating an existing doorbell. When the doorbell is heard, the tenant can choose to either pick up a phone or open the door to talk to the visitor. Even though ringing is disabled, the C-200 will still provide call waiting beeps if the tenant is on a phone call.
  • Page 7 C-200 or C-2000A Entry Phone controller. The E-40 entry phones can also be connected to an unused analog sta- tion port (programmed for ring down) on a phone system or connected directly to a telephone line when used with a Viking model K-1900-5 auto dialer.
  • Page 8 C-2000A, dial 715-386-4345 and request Fax Back Document 156. Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no respon- sibility for errors and omissions contained in this information.

This manual is also suitable for:

C-2000aE-10aE-20bE-30E-35E-40 ... Show all

Table of Contents