Dual Rear Fan Module
The SSG-6049P-E1CR60H/L/L+ supports two rear-mounted cooling fans in a hot-swappable
dual fan unit. Refer to the procedure below for replacing these fans.
1. While the power is running, examine the fans to determine which fan has failed.
2. Simultaneously press the upper and lower release tabs of the dual fan module.
3. Pull the fan out of the rear of the storage chassis using the handle provided.
CAUTION: Fans will continue to rotate for a brief time after removing them from the storage
chassis. To avoid injury, keep fingers clear of the rotating fan blades.
4. Place the new fan into the vacant fan bay and push it in until it clicks into the locked
position.
5. Confirm that the fan is fully seated in the fan bay and functioning properly.
3
Figure 3-14. Removing the Dual Fan Housing from the System
Chapter 3: Maintenance and Component Installation