19
PRO MODE OPERATION DESCRIPTION
Part description
UP (+) key (Select)
DOWN (-) key (Select)
MODE key
(Select, cancel)
MODE indicator: PRO (Yellow)
Response time
<PRO1>
setting (Note 1)
SET
SET
Notes: 1) Display of incident light intensity depends on the response
+, -
Timer setting
SET
ON-delay / One-
shot timer
(Except sensing output 2)
Notes: 2) When using time, be sure to set the time range.
+, -
Hysteresis setting
SET
+, -
+, -
+, -
Shift amount
setting
SET
Notes: 3) Incident light intensity setting depends on the response
+, -
Light-receiving
sensitivity setting
SET
+, -
Emission halt
setting
SET
+, -
Timer range
setting
SET
Teaching lock
<PRO2>
setting
SET
SET
+, -
Setting items in
digital display
setting
SET
+, -
Setting of digital
display turning
SET
+, -
+, -
ECO setting
SET
+, -
Time period hold
setting (Note 4)
SET
+, -
Notes: 4) In order to clear the value, set the time period holding
Symbol explanation
SET
: Press the SET key
+, -
: Press the UP (+) key or
DOWN (-) key.
Automatic
: Automatically move to next
5ms or less
24ms or less
+, -
+, -
+, -
+, -
+, -
time.
Response time
Incident light intensity
"
", "
", "
"
Max. 4,000
"
", "
", "
"
Max. 9,999
No timer
OFF-delay timer
ON-delay timer
+, -
+, -
+, -
+, -
+, -
One-shot timer
ON / OFF-delay timer
(Except sensing output 2)
Since the setting time depends on timer range as table
below, set the setting time after selecting the timer range.
Timer range
Timer period
"ms"
Approx. 0.5ms, Approx. 1 to 9,999ms
"sec."
Approx. 0.5 sec., Approx. 1 to 32 sec.
"1/10ms"
Approx. 0.05ms, Approx. 0.1 to 999.9ms
Standard
Large
+, -
+, -
+, -
Displayed in
Incident light
percentage
intensity (Note 3)
+, -
times.
Response time
Incident light intensity
"
", "
", "
"
Max. 4,000
"
", "
", "
"
Max. 9,999
Incident light
intensity
Level 4
+, -
SET
+, -
+, -
Level 3
Emission
Emission halt
+, -
ms
sec.
+, -
+, -
+, -
Lock OFF
Lock ON
+, -
Incident light
Displayed in
Peak / bottom
intensity
percentage
value
+, -
+, -
+, -
Turning OFF
Turning ON
+, -
Eco OFF
Eco ON
+, -
+, -
+, -
Hold OFF
Hold ON
+, -
function to OFF once. Turning the power OFF can also
clear the value.
+, -
<PRO3>
SET
+, -
+, -
+, -
<PRO4>
SET
+, -
+, -
Small
Level 1
+, -
Level 2
1/10ms
+, -
Full
Data bank loading
setting
1ch
SET
+, -
Changeable 1 to
+, -
8ch in + or -
Automatic
Data bank saving
setting
1ch
+, -
SET
Changeable 1 to
+, -
8ch in + or -
Automatic
Back up setting
Back up ON
+, -
SET
+, -
Input / output setting
Sensing output 2
+, -
SET
YES
Copy setting
+, -
SET
Automatic
+, -
Copy action setting
Display adjustment
+, -
SET
+, -
Copy lock setting
Copy lock OFF
+, -
SET
+, -
Communication
Communication
protocol setting
mode
+, -
SET
+, -
External input set-
ting (Note 5)
Only one unit
SET
SET
+, -
Display adjustment
All
SET
Display adjustment
Notes: 5) The signal input time from outside is as follows.
2 point teaching
Limit teaching
20 to under 500ms
Display adjust
Full auto teaching
600ms or more (sampling during input)
Emission OFF, Logic setting
2ms or more (conducted during inputting)
Copy lock
Data bank loading
(1 pulse: 16 to 300ms).
Data bank saving
However, the pulse cycle is under 500ms.
YES
good
+, -
Blink
Blinks
3 times
YES
good
+, -
Blink
Blinks
3 times
Back up OFF
External input
good
Automatic
2 turns
Display adjustment
Display copy
OFF
+, -
+, -
Copy lock ON
Communication
emission halt
Emission OFF
Teaching
+, -
+, -
Limit +
+, -
+, -
Copy lock
Limit -
+, -
+, -
Logic setting
+, -
+, -
Data bank save
Data bank load
+, -
Emission OFF
Teaching
+, -
+, -
Limit +
+, -
+, -
Limit -
+, -
+, -
Data bank save
Data bank load
+, -
Input time