   Selection table of separate-type options
Applicable
Voltage
motor
class
[kW]
18.5
VFP7-2185P
22
VFP7-2220P
30
VFP7-2300P
37
VFP7-2370P
200V
45
VFP7-2450P
class
55
VFP7-2550P
75
VFP7-2750P
90
VFP7-2900P
110
VFP7-2110KP
18.5
VFP7-4185P
22
VFP7-4220P
30
VFP7-4300P
37
VFP7-4370P
45
VFP7-4450P
55
VFP7-4550P
75
VFP7-4750P
400V
90
VFP7-4900P
class
110
VFP7-4110KP
132
VFP7-4132KP
160
VFP7-4160KP
200
VFP7-4200KP
220
VFP7-4220KP
280
VFP7-4280KP
315
VFP7-4315KP
(*1): This filter needs to be wound 4 turns or more around with the input side power line. This filter can
be used for the output side in the same manner. For the wire whose size is 22 mm
at least 4 filters in series. Round type (Model: RC5078) is also available.
(*2): For a motor noise reduction filter for this class, please consult.
(*3): PBR3-□□□□ indicates braking resistor, PB3-□□□□ indicates braking unit (dynamic braking
drive circuit and braking resistor(s) are built in it).
(*4): Model in square brackets is fitted with top cover.
(*5): To use 200 V-75 kW or more or 400 V-110 kW or more inverter with an external braking resistor
(DGP600 series), installation of a dynamic braking drive circuit inside the inverter is required.
(*6): There is a case that this filter is unusable depending on the type or size of the cable to be used.
(*7): About this filter for inverter models of 90 kW or more, consult with our office
(*8): Be sure to connect DC reactor to 200V-75kW or more or 400V-110kW or more inverter. (Not
necessary for DC input.)
Input AC
Inverter
DC reactor
reactor
model
(DCL)
(ACL)
PFL-2100S DCL-2220
PFL-2150S DCL-2370 NF-3150A-MJ
PFL-2200S DCL-2450 NF-3200A-MJ
PFL-2300S DCL-2550 NF-3250A-MJ
PFL-2400S DCL-2750
PFL-2600S DCL-2900
PFL-4050S DCL-4220
PFL-4100S DCL-4450
PFL-4150S DCL-4750 NF-3150C-MJ
PFL-4300S DCL-4110K NF-3250C-MJ
PFL-4400S DCL-4160K
PFL-4600S DCL-4220K
PFL-4800S DCL-4280K
Radio noise reduction filter
High
Core
Simple
attenuation
type
type
type
(*1)
NF-3080A-MJ
NF-3100A-MJ
RC9129
RCL-M2
NF-3200A-MJ
RC9129
×2 (parallel)
(*6)
NF-3250A-MJ
×2 (parallel)
NF-3040C-MJ
NF-3050C-MJ
NF-3060C-MJ
RC9129
NF-3080C-MJ
NF-3100C-MJ
RCL-M4
NF-3200C-MJ
RC9129
×2 (parallel)
(*6)
NF-3250C-MJ
×2 (parallel)
NF-3250C-MJ
×3 (parallel)
I-9
Motor end
Braking resistor
surge voltage
/Braking unit
suppression
(*3, 4, 5)
filter
PBR3-2150
PBR3-2220
PB3-2300
PB3-2550
DGP600W-B1
[DGP600W-C1]
PBR3-4150
MSF-4220Z
PBR3-4220
PB3-4300
MSF-4370Z
MSF-4550Z
PB3-4550
MSF-4750Z NRL-4155
DGP600W-B2
[DGP600W-C2]
(*7)
DGP600W-B3
[DGP600W-C3]
DGP600W-B4
[DGP600W-C4]
2
or more, install
Motor
noise
reduction
filter
NRL-2220
NRL-2300
NRL-2400
(*2)
NRL-4230
NRL-4300
NRL-4350
NRL-4600
NRL-4550
(*2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents