kozy heat OCK-S50A Manual
kozy heat OCK-S50A Manual

kozy heat OCK-S50A Manual

Propane conversion kit

Advertisement

Available languages

Available languages

Quick Links

PROPANE CONVERSION KIT
#OCK-S50A
For use with the #CSK-335S
Direct Vent Gas Fireplace Insert
STARTING SERIAL NUMBER:
This fireplace is certified under U.S. and Canadian standards ANSI Z21.88-2017/CSA 2.33-2017, CSA 2.17-2017
IMPORTANT
THE CONVERSION SHALL BE CARRIED OUT BY A
MANUFACTURER'S
AUTHORIZED
IN ACCORDANCE WITH THE REQUIREMENTS OF THE
MANUFACTURER,
PROVINCIAL
AUTHORITIES
HAVING
ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/
CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
CETTE CONVERSION DE GAZ DOIT ÊTRE EFFECTUÉE
PAR UN REPRÉSENTANT AUTORISÉ DU FABRICANT,
CONFORMÉMENT AUX EXIGENCES DU FABRICANT ET
DES AUTORITÉS PROVINCIALES OU TERRITORIALES
AYANT JURIDICTION, ET AUX EXIGENCES DES
CODES D'INSTALLATION CAN/CGA-B149.1 OU CAN/
CGA-B149.2.
WARNING
This conversion kit shall be installed by
a qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fire, explosion or
productions of carbon monoxide may
result, causing property damage, personal
injury, or loss of life. The qualified service
agency is responsible for proper installation
of this kit. The installation is not proper and
complete until operation of the converted
appliance is checked as specified in the
manufacturer's instructions supplied with
the kit. Refer to appliance owner's manual
or product data plate for proper inlet and
manifold pressure adjustments and orifice
sizing.
Hussong Manufacturing Co., Inc.
P.O. Box 577, 204 Industrial Park Drive
Lakefield, MN 56150-0577, USA
21 712839 45
REPRESENTATIVE,
OR
TERRITORIAL
JURISDICTION
AND
IN
HUSSONG MANUFACTURING CO., INC.
READ ALL STEPS BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
This gas conversion kit installation instructions must be used in
conjunction with the installation and operation manual provided with
the appliance. Please read the appliance owner's manual completely
before performing any procedures in these instructions. All warnings,
precautions, and instructions outlined in the manual provided with the
appliance will continue to apply to these instructions.
AVERTISSEMENT
Ce kit de conversion doit être installé par
une agence d'entretien qualifiée, selon
les instructions du fabricant et tous codes
et règlements applicables de l'autorité
ayant juridiction. Le non-respect de ces
instructions peut créer un incendie, une
explosion ou la production de monoxyde de
carbone, et causer des dommages matériels,
des blessures ou même la mort. L'agence
d'entretien qualifiée est responsable de la
qualité d'installation de ce kit. L'installation
ne sera conforme et complète qu'après
avoir vérifié le fonctionnement du foyer
converti, tel que spécifié dans les instructions
du propriétaire fournies avec ce kit. Voir
le manuel d'utilisation ou la plaque
signalétique de l'appareil, pour les réglages
de pressions d'entrée et du manifold et les
dimensions d'orifice (injecteur) de brûleur/
veilleuse.
EN
FR
PG
6
CSK-335S • Rev. 10, 11/21
Report Number: 18-455

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OCK-S50A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for kozy heat OCK-S50A

  • Page 1 PROPANE CONVERSION KIT #OCK-S50A HUSSONG MANUFACTURING CO., INC. For use with the #CSK-335S Direct Vent Gas Fireplace Insert 21 712839 45 STARTING SERIAL NUMBER: This fireplace is certified under U.S. and Canadian standards ANSI Z21.88-2017/CSA 2.33-2017, CSA 2.17-2017 IMPORTANT THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER’S...
  • Page 3 Conversion Kit Components C. PSE - Convert Pilot Assembly (1) Gas Conversion Label 7/16 Step 1: Using a ” wrench, loosen and remove pilot hood by (1) Valve and Pilot Assembly Conversion Instructions turning it counter clockwise. (1) Gas Label Step 2: Remove pilot orifice located inside pilot housing.
  • Page 4 D. SIT - Convert Pilot Assembly Step 1: Remove and save the clip securing the pilot hood to the pilot bracket. Remove pilot hood by pulling directly up from the pilot bracket. 5/32 Step 2: Insert a ” (4mm) hex key into the hexagonal key-way of Access Cover the injector, and turn counterclockwise to remove it from the injector journal.
  • Page 5 turning screw clockwise. Screw should be snug. Do not over tighten. Step 9: Relight pilot and turn the gas control knob to ON. Reattach manometer to the inlet pressure tap to verify tap is completely sealed. Manometer should read no pressure. Table 3, Inlet Gas Supply Pressures BURNER Fuel...
  • Page 6 Composants du kit de conversion C. Convertir l’ensemble de veilleuse - PSE (1) Étiquette de conversion de gaz Étape 1: Avec une clé de 7/16 po, desserrez et retirez le capuchon (1) Instructions de conversion du robinet de gaz et de la veilleuse de veilleuse en tournant en sens anti-horaire (inverse des aiguilles d’une montre).
  • Page 7 D. Convertir l’ensemble de veilleuse Étape 3: Suivez les directives du feuillet d’instructions du régulateur de pression (moteur pas-à-pas), pour convertir Étape 1: Retirez le clip de fixation qui retiennent le capuchon de la valve de contrôle de gaz. veilleuse à du support de veilleuse. Retirez le capuchon Étape 4: Glissez le couvercle d’accès au boîtier externe jusqu’à...
  • Page 8 G. Test de pression à l’entrée montre) pour réduire la flamme de la veilleuse, ou en sens anti-horaire (sens inverses des aiguilles d’une montre) IMPORTANT : Effectuez tous les tests de pression avec tous les pour augmenter la flamme de la veilleuse. Réinstallez le appareils à...

This manual is also suitable for:

21 712839 45