BEFORE YOU BEGIN
BEFORE YOU BEGIN
!
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
!
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
!
These instructions contain important care, cleaning, and
warranty information -
consumer
.
!
Observe all local plumbing and building codes.
!
Carefully inspect the new urinal for damage.
!
Site preparation may require additional tools and
hardware.
!
Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2018).
·
The product complies with GB/T 6952-2015.
CAUTION: Risk of personal injury or product
damage.
Handle with care. Vitreous china can break
or chip if the product is handled carelessly.
RECOMMENDED TOOLS AND MATERIALS (NOT SUPPLIED)
RECOMMENDED TOOLS AND MATERIALS (NOT SUPPLIED)
!
Open end/adjustable wrenches
!
Tape measure
!
Basin wrench
!
Pipe wrench
!
Square
!
Level
!
Pliers
!
Socket wrench with sockets
!
Screw driver
!
Seal tape
!
Drill
!
Sealant
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA
NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC
1323700-T01-B
TOUCHLESS WALL HUNG URINAL W/ELECTROLYZED WATER 1L/AC
TOUCHLESS WALL HUNG URINAL W/ELECTROLYZED WATER 3L/AC
TOUCHLESS WALL HUNG URINAL W/ELECTROLYZED WATER & IOT 0.5L/AC
please leave instructions for the
MODERN LIFE
TOUCHLESS WALL HUNG URINAL 3L
K-21841T(
!
!
!
!
!
!
!
2018)
·
GB/T 6952-2015
!
/
!
!
!
!
!
!
!
!
!
!
!
2
528137
8
256410
1
110400
©
Copyright Kohler China Investment Co., Ltd. 2019
-1-
©
INSTALLATION INSTRUCTIONS
)/K-21841T-C05(
K-21841T-WEW
K-21841T-EW
(
) (0.5L)
K-21841T-YXEW
ASME
(A112.19.2-
(
)
POST CODE:
256410
POST CODE:
(3L)
)
(
) (1L)
(
) (3L)
-
:
110400
2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MODERN LIFE K-21841T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kohler MODERN LIFE K-21841T

  • Page 1 Socket wrench with sockets Screw driver Seal tape Drill Sealant No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410 256410 NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC...
  • Page 2: Specifications

    SPECIFICATIONS K-21841T(DC w/o Electrolyzed Water 3L) K-21841T-C05(AC w/o Electrolyzed Water 3L) K-21841T-WEW(AC with Electrolyzed Water 1L) Model K-21841T-EW(AC with Electrolyzed Water 3L) K-21841T-YXEW(w/Electrolyzed Water & IOT AC 0.5L) DC power unit 4 "AA" size alkaline batteries (Batteries For Largess) AC/DC transformer input AC 220V 50/60Hz (Sold Separately) Power AC/DC Switch Power input AC 220V 50/60Hz Water pressure at 0.18~0.55 MPa: Average no more than 0.5L...
  • Page 3 Reference Value Supply Waste Pipe Floor Fig.1 Kohler reserves the right to change marked dimensions without prior notice. Notice: a. The dimensions above are just for reference. b. * Indicates the location of inlet pipe, while inlet b. * G 1/2 connector size is G 1/2.
  • Page 4: Prepare The Site

    PREPARE THE SITE PREPARE THE SITE NOTE: If a pre-existing waste pipe will be used and will result in an acceptable rim height (refer to the rough-in dimensions), follow the retrofit installation instructions. For Retrofit Installations Turn the water supply line off, remove the existing urinal, then cap off the water supply line inside the wall.
  • Page 5: Installation

    INSTALLATION Install and uninstall the sensor controller a. Install the sensor controller box. b. Install the screw. c. Connect the sensor wire. Install and uninstall the Fixture, Valve Assembly Unscrew the screws on the Fixture, Valve Assembly. Remove the Fixture, Valve Assembly from the urinal by moving it. Install the Greeting light Assembly (K-21841T-WEW/K-21841T-EW/K-21841T- (For K-21841T-WEW/K-21841T-EW/K-...
  • Page 6 Install DC Power Unit (17) (18) 1. Take out battery case assy., and loosen the screws (17). (18) (17) Place 4 AA batteries into the battery case according to negative and positive electrode marks on the battery case cover (18). Tighten the screws on the battery case cover (18).
  • Page 7 B. When installing the power uint in the bracket, please layout bushing according to Fig.7 and thread wire through the bushing. Fig.7: Connection sketch while installing power uint in the bracket. CAUTION: One AC power unit can supply one sensors at most. Control Box Asm Bushing AC Power Unit...
  • Page 8 Install hangers, L shape block and waste pipe connector Install hangers, L shape block and waste pipe connector according to RI. NOTE: 1. Gasket of waste pipe connector shall be soaked into water for 2 seconds to lubricate. 2. Shorten the connector if necessary to match the waste pipe on the wall.
  • Page 9 3. Connect inlet pipe with corner valve. 4. Lift the urinal and insert the connector into the waste pipe on the wall. 5. Hang the urinal onto the hangers. If the hangers need to be adjusted, please fisrt take down the urinal.(Refer to Adjust the hanger) 6.
  • Page 10 2. As shown in the picture below, if the position of the urinal needs to be adjusted, please take down the urinal and knock the hanger slightly to adjust its position upwards and downwards. Adjust Upwards and Downwards Fig.13 3. After the position of the urinal is decided, completely fix the hanger with the bolt through the fixing holes on the hanger.
  • Page 11 Install fragrance porcelain (for K-21841T-YXEW only) K-21841T-YXEW) 1. Insert the scent top into the plug. 2. Take out the tube. Fill fragrance into the tube. Do not overfill to avoid overflow. 3. Insert the plug into the tube. 4. Insert the tube into the hole on the urinal cover.
  • Page 12: Maintenance

    MAINTENANCE Clean the Filter Screen If the flushing volume reclines sharply after installation or used for a long time with no cause from water pressure, the filter may need a wash. Please operate as following steps: Remove the fixed cap and take out the filter, clean the filter and then reinstall it.
  • Page 13: Important Consumer Information

    (calcium hypochlorite) can seriously damage fittings in the urinal. This damage can cause leakage and property damage. Kohler Company shall not be responsible or liable for any damage to these urinal fittings caused by the use of cleaners containing chlorine (calcium hypochlorite).
  • Page 14 WARNING Never spit phlegm and throw stub or something else into the urinal. WARNING: Risk of product damage. Do not throw into the urinal what is easy to block it, such as newspaper, paper pilch. Do not bump the vitreous china with great force to prevent it from damaging and leaking.

Table of Contents