Medify Air MA-40UV - True HEPA Air Purifier with UV Light Manual
![]()
IMPORTANT SAFETY INSTRUCTIONS
IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING SAFETY PRECAUTIONS:
IF THE POWER CORD OR UNIT DOES NOT WORK, CONTACT MEDIFY CUSTOMER SERVICE IMMEDIATELY.
READ ALL INSTRUCTIONS BEFORE USING.
![burn hazard]()
![]()
![burn hazard]()
TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:
- DO NOT touch the power plug with wet hands.
- Turn off the power before cleaning the unit.
- DO NOT use the air purifier in rooms where fumigation or pesticide is being used.
- Keep the unit dry.
- DO NOT use air purifier in a room where oils or grease are being cooked with; that may clog the filters.
- Use ONLY a soft clean cloth. DO NOT use solvents like Benzene, Alcohol or any flammable cleaners to clean the air purifier.
- This is a 120V unit. It is NOT made for 220V use. Plugging it into a 220V outlet will damage the motor and circuits and the unit will not work any longer. Use only with a 120V outlet.
To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet. Do not alter the plug in any way. - BEFORE USING THIS PRODUCT, PLEASE MAKE SURE TO REMOVE THE PLASTIC COVERING FROM ALL FILTERS.
- Turn off the power immediately in case of any of the following:
- Malfunction of any switch
- Circuit failure
- Abnormal heating of wires or plugs
- Any other malfunction
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid any type of hazard. This appliance can be used by children aged from 8 years and above and people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance of the unit shall not be made by children without supervision. Prior to cleaning or doing any type of maintenance, the appliance must be disconnected from the power supply.
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.
FIVE-STEP FILTER PURIFICATION SYSTEM
- PRE FILTER
Removes hair, fibers, and large particles like dander.
- TRUE HEPA H14 FILTER
HEPA H14 is a higher grade of TRUE HEPA that can remove 99.99% of particles down to 0.1 microns as well as PM2.5 particles such as smoke, pollen, dust mites and others.
![]()
- ACTIVATED CARBON FILTER
Substantial carbon filter with carbon pellets remove odors, and smoke.
![]()
- IONIZER
Produces negative ions to neutralize positively charged particles such as dust, pollen, animal dander and other airborne positive particles.
![]()
- UV LIGHT
Freshens air with UV light function.
To purchase genuine Medify replacement filters, visit www.medifyair.com.
TECHNICAL DATA
- Voltage: 120 V AC 60 Hz
- Rated power: 68 W
- Noise level: <66 dB(A)
- Unit dimensions: 22"H x 9.9"W x 10.9"D
- Unit weight: 15.5 lbs.
- EPA Est. No.:99452-CHN-1
STANDARD COVERAGE
Up to 1,600 sf every 60 minutes, up to 840 sf every 30 minutes, 420 sq. ft every 15 minutes.
DEVICE PARTS
![Medify Air - MA-40UV - DEVICE PARTS DEVICE PARTS]()
WHEN AND WHERE TO USE THE DEVICE
When you want to remove air pollutants, you can purify the air with one of our air purifiers. You can use these air purifiers in the rooms at your home, at the office, and/or even at a hotel. This air purifier is used to remove airborne contaminants from the indoor air in a particular area which could be potentially harmful to breathe.
BEFORE USE
OPENING AND REPLACING THE BACK COVER
- Press the tabs on the back cover and pull on the cover. Then lift the back cover and pull out slightly.
![Medify Air - MA-40UV - OPENING THE BACK COVER OPENING THE BACK COVER]()
- To reinstall the side covers, align the fixed slots and insert the covers into the slots. The covers will automatically snap back into place.
![Medify Air - MA-40UV - REPLACING THE BACK COVER REPLACING THE BACK COVER]()
INSTALLING THE UNIT
![Medify Air - MA-40UV - INSTALLING THE UNIT INSTALLING THE UNIT]()
Do not obstruct the air intake or the clean air outlet. To ensure proper air circulation, leave at least 1O" space between the back air intake and the wall or the furniture.
INSTALLING THE FILTER
The 3 stage Medify filter is a one-piece filter for higher performance. Remove the old filter by pulling on the small tab at top. When reinstalling the new filter, make sure to push it back in and make sure that it is affixed snuggly for maximum performance.
- Place the machine in a dry location and on a smooth and flat surface.
![Medify Air - MA-40UV - INSTALLING THE FILTER - Step 1 - Place the unit INSTALLING THE FILTER - Step 1 - Place the unit]()
- Press the top buttons in the back cover and pull the cover. Lift the back cover and pull out slightly.
![Medify Air - MA-40UV - INSTALLING THE FILTER - Step 2 - Open the cover INSTALLING THE FILTER - Step 2 - Open the cover]()
- Remove the filter by pulling on the small tab at the top of filter.
![Medify Air - MA-40UV - INSTALLING THE FILTER - Step 3 - Remove the filter INSTALLING THE FILTER - Step 3 - Remove the filter]()
- Remove any plastic packaging from the new filter before installing it in the air purifier.
![Medify Air - MA-40UV - INSTALLING THE FILTER - Step 4 INSTALLING THE FILTER - Step 4]()
- Place the new filter in the air purifier with the white side facing out towards you. The tab at the top of the filter should be facing you.
![Medify Air - MA-40UV - INSTALLING THE FILTER - Step 5 - Place new filter INSTALLING THE FILTER - Step 5 - Place new filter]()
- Replace the back cover.
ATTENTION
Remove all plastic packaging from the filter before installing it.
DO NOT run the air purifier if there is no filter installed.
CONTROL PANEL
![Medify Air - MA-40UV - CONTROL PANEL CONTROL PANEL]()
HOW TO USE
BEFORE TURNING THE UNIT ON
- Take the air purifier out of the box and remove the clear protective plastic bag.
- Place the air purifier on a firm, leveled surface.
- Plug the power cord into a standard AC outlet. After plugging it in, the air purifier will beep. All the indicator lights will flash 1 time, including the power light indicator. Then, the unit will enter standby mode.
- To turn the air purifier on, press the power
button. - The unit will start working in low speed. Press the
button again so the machine stops and enters standby mode. - This air purifier has 4 fan speed settings: low, medium, high and sleep mode. The higher the fan speed setting, the faster the air will be purified. To select or change fan speed, press the fan speed button until the desired setting is reached.
TIMER
Press the timer button and choose your preferred hour option: 1, 2, 4, 8 or no timer.
IONIZER MODE
Ionizer is an On/Off function. You can choose to leave it on or off at your discretion. When Ionizer is on, the indicator light will be lit.
Pressing the UV button will turn on the UV indicator, and the UV function will run for 20 minutes. After 20 minutes, the UV function will automatically turn off. Alternatively, if the UV feature is currently running, you can press the UV button again to turn off the UV function.
It is not recommended for users to attempt to replace the UV lamp.
To turn on the child lock, press and hold the button down for 3 to 5 seconds. To turn off the child lock function, press and hold down this button again for 30 to 45 seconds. While in the Child-Lock mode, none of the function keys can be used or changed (except for the child lock function).
CLEANING AND MAINTENANCE
Unplug the air purifier before cleaning it. Do not use too much water to clean the unit. Use a soft and wet cloth to clean the unit. Do not ever use any cleaners or chemicals on the air purifier.
CLEANING THE AIR PURIFIER
From time to time, if you see too much dust accumulated on the unit, wipe it with a clean dry cloth. Also, make sure that both the air intake and the vents are free from dust. DO NOT vacuum or try to wash the filter
FILTER REPLACEMENT
LIGHT INDICATOR TO REPLACE THE FILTER
It reminds the user when the filter needs to be replaced. The indicator icon will become lit when the filter
- lndicator Lights will show the user if the filters need to be replaced. Make sure to unplug the unit before changing the filter.
![Medify Air - MA-40UV - FILTER REPLACEMENT - Step 1 FILTER REPLACEMENT - Step 1]()
- Press the top buttons on the back cover and pull the cover. Lift the back cover and pull out slightly.
![Medify Air - MA-40UV - FILTER REPLACEMENT - Step 2 - Open the cover FILTER REPLACEMENT - Step 2 - Open the cover]()
- Remove the old filter from the unit by pulling on the tab at the top.
![Medify Air - MA-40UV - FILTER REPLACEMENT - Step 3 - Remove old filter FILTER REPLACEMENT - Step 3 - Remove old filter]()
- Remove any plastic packaging from the new filter before installing it in the air purifier. Place the new filter in the air purifier with the white side facing towards you.
- Replace the back cover.
- Resetting the Filter indicator Light:
Once the new filter has been installed and the unit is turned back on: Hold down the FAN SPEED button and the IONIZER button at the same time for 3-5 seconds. Then, the indicator light will go off and the timer will be reset for 3,000 hours.
www.medifyair.com
info@medifyair.com
(888) 258-1008
Please visit our website for details on efficacy test data: medifyair.com/pages/reports
![]()
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Medify Air MA-40UV - True HEPA Air Purifier with UV Light Manual
Need help?
Do you have a question about the MA-40UV and is the answer not in the manual?
Questions and answers