3.2 SANITISING INSTRUCTIONS

The disinfection of the product after installation is very important to ensure that there is no
residue on the machine due to transport and testing that can leave a bad taste in the water.
Always ensure proper ventilation and use proper personal protective equipment such as gloves
!
and eye protection when using chemicals. Refer to material safety data sheet for specific
requirements of each chemical product. Take all necessary precautions to prevent sanitiser from
contacting eyes, clothing, and any other surfaces it could damage.
Turn OFF the water supply and open the
1
front panel [9] to access the filter.
3
Turn ON the water supply.
5
Dispense cold water until water with
sanitiser solution comes out the faucet.
Ensure CO
supply is on and dispense 500 ml
2
of sparkling water from the faucet. This will
7
let the pump refill the tank with water that
contains sanitiser solution.
17
9
INSTALLATION INFORMATION
Replace the filter with the housing with
2
the sanitiser inside (30 ml). Bypass the other
filters if applicable.
4
Ensure the green (chapter 2.5 [22]).
Compressor and heater switch is OFF.
6
Repeat the process with the ambient water.
Turn OFF the water supply and replace the
filter housing with the original filter.
8
0